Bilateral Comparison Between CMI and CEM in Radiance Temperature Scale Realization from \(232\,^{\circ }\mathrm{C}\) to \(1085\,^{\circ }\mathrm{C}\)

  • Published:
International Journal of Thermophysics Aims and scope Submit manuscript

Abstract

A bilateral comparison between the Centro Español de Metrología (CEM) and the Český Metrologický Institut (CMI) of radiance temperature scale realizations in the range from \(232\,^{\circ }\mathrm{C}\) to \(1085\, ^{\circ }\mathrm{C}\) was carried out during 2012 to support the calibration measurements capabilities of CMI in radiation thermometry. The CEM capabilities were demonstrated previously in a recent comparison of European laboratories over the range from \(156\,^{\circ }\mathrm{C}\) to \(1000\,^{\circ }\mathrm{C}\). A CMI KE-LP5 radiation thermometer, working at 1568 nm, was used as a traveling standard. CEM measurements were done at the fixed-points (FPs) of Zn, Ag, and Cu and, for the rest of the temperatures, variable temperature blackbodies (VTBBs) were used. CMI measurements were done at the FPs of Sn, Al, and Cu, and the rest of the temperatures were measured with VTBBs. The size-of-source effect was measured at CEM to decide whether or not the measurements from both laboratories should be corrected by this effect (when the diameter of the sources was different at each laboratory). CMI performed the measurement of the Al FP before and after CEM to evaluate the stability of the radiation thermometer. The results for both laboratories are summarized, and they agree within their expanded uncertainties.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. P. Saunders, Metrologia 34, 201 (1997)

    Article  ADS  Google Scholar 

  2. H. McEvoy, M.J. Martin, A. Steiner, E. Schreiber, F. Girard, M. Battuello, M. Sadli, P. Ridoux, B. Gutschwager, J. Hollandt, A. Diril, Ö. Pehlivan, Int. J. Thermophys. (submitted)

  3. J. Fischer, P. Saunders, M. Sadli, M. Battuello, C.W. Park, Y. Zundong, H. Yoon, W. Li, E. van der Ham, F. Sakuma, Y. Yamada, M. Ballico, G. Machin, N. Fox, J. Hollandt, M. Matveyev, P. Bloembergen, S. Ugur, CCT-WG5 document, “Uncertainty Budgets for Calibration of Radiation Thermometers Below the Silver Point” (BIPM, Sèvres Cedex, 2008)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to M. J. Martín.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Martín, M.J., Kňazovická, L., del Campo, D. et al. Bilateral Comparison Between CMI and CEM in Radiance Temperature Scale Realization from \(232\,^{\circ }\mathrm{C}\) to \(1085\,^{\circ }\mathrm{C}\) . Int J Thermophys 35, 475–484 (2014). https://doi.org/10.1007/s10765-014-1576-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10765-014-1576-6

Keywords

Navigation