How reliable are left ventricular ejection fraction cut offs assessed by echocardiography for clinical decision making in patients with heart failure?

  • Original Paper
  • Published:
The International Journal of Cardiovascular Imaging Aims and scope Submit manuscript

Abstract

We aimed to study the potential influence of the variability in the assessment of echocardiographically measured left ventricular ejection fraction (LVEF) on indications for the implantation of internal cardioverter defibrillator and/or cardiac resynchronization devices in heart failure patients. TIME-CHF was a multicenter trial comparing NT-BNP versus symptom-guided therapy in patients aged ≥60 years. Patients had their LVEF assessed at the recruiting centre using visual assessment, the area-length or biplane Simpson’s method. Echocardiographic data were transferred to the study core-lab for re-assessment. Re-assessment in the core-lab was done with biplane Simpson’s method, and included an appraisal of image quality. 413 patients had the LVEF analyzed at the recruiting centre and at the core lab. Image quality was optimal in 191 and suboptimal in 222. Overall, the correlation between LVEF at the recruiting centres and at the core-lab was good, independent of image quality (R² = 0.62). However, when a LVEF ≤30 % or ≥30 % was used as a cut-off, about 20 % of all patients would have been re-assigned to having either a LVEF above or below the cut-off, this proportion was not significantly influenced by image quality. We conclude that correlation between LVEF assessed by different centres based on the same ultrasound data is good, regardless of image quality. However, one fifth of patients would have been re-assigned to a different category when using the clinically important cut-off of 30 %.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Moss AJ, Zareba W, Hall WJ, Klein H, Wilber DJ, Cannom DS, Daubert JP, Higgins SL, Brown MW, Andrews ML (2002) Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. N Engl J Med 346:877–883

    Article  PubMed  Google Scholar 

  2. Bardy GH, Lee KL, Mark DB, Poole JE, Packer DL, Boineau R, Domanski M, Troutman C, Anderson J, Johnson G, McNulty SE, Clapp-Channing N, Davidson-Ray LD, Fraulo ES, Fishbein DP, Luceri RM, Ip JH (2005) Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure. N Engl J Med 352:225–237

    Article  PubMed  CAS  Google Scholar 

  3. Bristow MR, Saxon LA, Boehmer J, Krueger S, Kass DA, De Marco T, Carson P, DiCarlo L, DeMets D, White BG, DeVries DW, Feldman AM (2004) Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure. N Engl J Med 350:2140–2150

    Article  PubMed  CAS  Google Scholar 

  4. Hunt SA, Abraham WT, Chin MH, Feldman AM, Francis GS, Ganiats TG, Jessup M, Konstam MA, Mancini DM, Michl K, Oates JA, Rahko PS, Silver MA, Stevenson LW, Yancy CW (2009) Focused update incorporated into the acc/aha 2005 guidelines for the diagnosis and management of heart failure in adults: a report of the American college of cardiology foundation/american heart association task force on practice guidelines: developed in collaboration with the international society for heart and lung transplantation. Circulation 119:e391–e479

    Article  PubMed  Google Scholar 

  5. Dickstein K, Cohen-Solal A, Filippatos G, McMurray JJ, Ponikowski P, Poole-Wilson PA, Stromberg A, van Veldhuisen DJ, Atar D, Hoes AW, Keren A, Mebazaa A, Nieminen M, Priori SG, Swedberg K (2008) Esc guidelines for the diagnosis and treatment of acute and chronic heart failure 2008: the task force for the diagnosis and treatment of acute and chronic heart failure 2008 of the European society of cardiology. Developed in collaboration with the heart failure association of the esc (hfa) and endorsed by the European society of intensive care medicine (esicm). Eur Heart J 29:2388–2442

    Article  PubMed  CAS  Google Scholar 

  6. White HD, Norris RM, Brown MA, Brandt PW, Whitlock RM, Wild CJ (1987) Left ventricular end-systolic volume as the major determinant of survival after recovery from myocardial infarction. Circulation 76:44–51

    Article  PubMed  CAS  Google Scholar 

  7. Wong M, Johnson G, Shabetai R, Hughes V, Bhat G, Lopez B, Cohn JN (1993) Echocardiographic variables as prognostic indicators and therapeutic monitors in chronic congestive heart failure. Veterans affairs cooperative studies v-heft i and ii. V-heft va cooperative studies group. Circulation 87:VI65–VI70

    PubMed  CAS  Google Scholar 

  8. Randomised, placebo-controlled trial of carvedilol in patients with congestive heart failure due to ischaemic heart disease. Australia/new zealand heart failure research collaborative group. Lancet (1997) 349:375–380

  9. Effect of enalapril on survival in patients with reduced left ventricular ejection fractions and congestive heart failure. The solvd investigators. N Engl J Med (1991) 325:293–302

  10. Effects of metoprolol cr in patients with ischemic and dilated cardiomyopathy : the randomized evaluation of strategies for left ventricular dysfunction pilot study. Circulation (2000) 101:378–384

  11. Lang RM, Badano LP, Tsang W, Adams DH, Agricola E, Buck T, Faletra FF, Franke A, Hung J, de Isla LP, Kamp O, Kasprzak JD, Lancellotti P, Marwick TH, McCulloch ML, Monaghan MJ, Nihoyannopoulos P, Pandian NG, Pellikka PA, Pepi M, Roberson DA, Shernan SK, Shirali GS, Sugeng L, Ten Cate FJ, Vannan MA, Zamorano JL, Zoghbi WA (2012) Eae/ase recommendations for image acquisition and display using three-dimensional echocardiography. J Am Soc Echocardiogr 25:3–46

    Article  PubMed  Google Scholar 

  12. Pfisterer M, Buser P, Rickli H, Gutmann M, Erne P, Rickenbacher P, Vuillomenet A, Jeker U, Dubach P, Beer H, Yoon SI, Suter T, Osterhues HH, Schieber MM, Hilti P, Schindler R, Brunner-La Rocca HP (2009) Bnp-guided vs symptom-guided heart failure therapy: the trial of intensified vs standard medical therapy in elderly patients with congestive heart failure (time-chf) randomized trial. JAMA 301:383–392

    Article  PubMed  CAS  Google Scholar 

  13. Brunner-La Rocca HP, Buser PT, Schindler R, Bernheim A, Rickenbacher P, Pfisterer M (2006) Management of elderly patients with congestive heart failure—design of the trial of intensified versus standard medical therapy in elderly patients with congestive heart failure (time-chf). Am Heart J 151:949–955

    Article  PubMed  Google Scholar 

  14. Lang RM, Bierig M, Devereux RB, Flachskampf FA, Foster E, Pellikka PA, Picard MH, Roman MJ, Seward J, Shanewise JS, Solomon SD, Spencer KT, Sutton MS, Stewart WJ (2005) Recommendations for chamber quantification: a report from the American society of echocardiography’s guidelines and standards committee and the chamber quantification writing group, developed in conjunction with the European association of echocardiography, a branch of the european society of cardiology. J Am Soc Echocardiogr 18:1440–1463

    Article  PubMed  Google Scholar 

  15. Tighe DA, Rosetti M, Vinch CS, Chandok D, Muldoon D, Wiggin B, Dahlberg ST, Aurigemma GP (2007) Influence of image quality on the accuracy of real time three-dimensional echocardiography to measure left ventricular volumes in unselected patients: a comparison with gated-spect imaging. Echocardiography 24:1073–1080

    Article  PubMed  Google Scholar 

  16. Erbel R, Schweizer P, Lambertz H, Henn G, Meyer J, Krebs W, Effert S (1983) Echoventriculography—a simultaneous analysis of two-dimensional echocardiography and cineventriculography. Circulation 67:205–215

    Article  PubMed  CAS  Google Scholar 

  17. Schalla S, Nagel E, Lehmkuhl H, Klein C, Bornstedt A, Schnackenburg B, Schneider U, Fleck E (2001) Comparison of magnetic resonance real-time imaging of left ventricular function with conventional magnetic resonance imaging and echocardiography. Am J Cardiol 87:95–99

    Article  PubMed  CAS  Google Scholar 

  18. Bellenger NG, Burgess MI, Ray SG, Lahiri A, Coats AJ, Cleland JG, Pennell DJ (2000) Comparison of left ventricular ejection fraction and volumes in heart failure by echocardiography, radionuclide ventriculography and cardiovascular magnetic resonance; are they interchangeable? Eur Heart J 21:1387–1396

    Article  PubMed  CAS  Google Scholar 

  19. Chuang ML, Hibberd MG, Salton CJ, Beaudin RA, Riley MF, Parker RA, Douglas PS, Manning WJ (2000) Importance of imaging method over imaging modality in noninvasive determination of left ventricular volumes and ejection fraction: assessment by two- and three-dimensional echocardiography and magnetic resonance imaging. J Am Coll Cardiol 35:477–484

    Article  PubMed  CAS  Google Scholar 

  20. Hoffmann R, von Bardeleben S, ten Cate F, Borges AC, Kasprzak J, Firschke C, Lafitte S, Al-Saadi N, Kuntz-Hehner S, Engelhardt M, Becher H, Vanoverschelde JL (2005) Assessment of systolic left ventricular function: a multi-centre comparison of cineventriculography, cardiac magnetic resonance imaging, unenhanced and contrast-enhanced echocardiography. Eur Heart J 26:607–616

    Article  PubMed  Google Scholar 

  21. Whalley GA, Gamble GD, Walsh HJ, Wright SP, Agewall S, Sharpe N, Doughty RN (2004) Effect of tissue harmonic imaging and contrast upon between observer and test–retest reproducibility of left ventricular ejection fraction measurement in patients with heart failure. Eur J Heart Fail 6:85–93

    Article  PubMed  Google Scholar 

  22. Shahgaldi K, Gudmundsson P, Manouras A, Brodin LA, Winter R (2009) Visually estimated ejection fraction by two dimensional and triplane echocardiography is closely correlated with quantitative ejection fraction by real-time three dimensional echocardiography. Cardiovasc Ultrasound 7:41

    Article  PubMed  Google Scholar 

  23. Cannesson M, Tanabe M, Suffoletto MS, McNamara DM, Madan S, Lacomis JM, Gorcsan J III (2007) A novel two-dimensional echocardiographic image analysis system using artificial intelligence-learned pattern recognition for rapid automated ejection fraction. J Am Coll Cardiol 49:217–226

    Article  PubMed  Google Scholar 

  24. Ray SG, Metcalfe MJ, Oldroyd KG, Pye M, Martin W, Christie J, Dargie HJ, Cobbe SM (1995) Do radionuclide and echocardiographic techniques give a universal cut off value for left ventricular ejection fraction that can be used to select patients for treatment with ace inhibitors after myocardial infarction? Br Heart J 73:466–469

    Article  PubMed  CAS  Google Scholar 

  25. Jenkins C, Bricknell K, Hanekom L, Marwick TH (2004) Reproducibility and accuracy of echocardiographic measurements of left ventricular parameters using real-time three-dimensional echocardiography. J Am Coll Cardiol 44:878–886

    Article  PubMed  Google Scholar 

Download references

Acknowledgments

Dr. Kaufmann is supported by a SCORE grant (SNF 32323B_123919/1) from the Swiss National Science Foundation. TIME-CHF was supported by the Horten Research Foundation (Lugano, Switzerland; >55 % of the study’s budget), as well as by smaller unrestricted grants from AstraZeneca Pharma, Novartis Pharma, Menarini Pharma, Pfizer Pharma, Servier, Roche Diagnostics, Roche Pharma, and Merck Pharma.

Conflict of interest

None declared.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Beat A. Kaufmann.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kaufmann, B.A., Min, S.Y., Goetschalckx, K. et al. How reliable are left ventricular ejection fraction cut offs assessed by echocardiography for clinical decision making in patients with heart failure?. Int J Cardiovasc Imaging 29, 581–588 (2013). https://doi.org/10.1007/s10554-012-0122-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10554-012-0122-5

Keywords

Navigation