Skip to main content
Log in

Microfluidic aqueous two phase system for leukocyte concentration from whole blood

  • Published:
Biomedical Microdevices Aims and scope Submit manuscript

Abstract

Leukocytes from a whole blood sample were concentrated using a microfluidic aqueous two phase system (μATPS). Whole blood was simultaneously exposed to polyethylene glycol (PEG) and dextran (Dex) phase streams and cells were partitioned based on their differential affinity for the streams. The laminar flow characteristic of microfluidic devices was used to create zero, one, and two stable interfaces between the polymer streams. Three different patterns of three polymer streams each were evaluated for their effectiveness in concentrating leukocytes: immiscible PEG-PEG-Dex, immiscible Dex-PEG-Dex, and miscible PEG-PBS-Dex. The most effective configuration was the Dex-PEG-Dex stream pattern which on average increased the ratio of leukocytes to erythrocytes by a factor of 9.13 over unconcentrated blood.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  • P. Albertsson, Nature 177, 771–774 (1956)

    Article  Google Scholar 

  • P. Albertsson, Partition of cell particles and macromolecules: separation and purification of biomolecules, cell organelles, membranes, and cells in aqueous polymer two-phase systems and their use in biochemical analysis and biotechnology. (Wiley, New York, 1986)

    Google Scholar 

  • R. Carlson, C. Gabel, S. Chan, R. Austin, J. Brody, J. Winkelman, Phys. Rev. Lett. 79, 2149–2152 (1997)

    Article  Google Scholar 

  • D. Gerson, Biochim. Biophys. Acta 602, 269–280 (1980)

    Article  Google Scholar 

  • L. Huang, E. Cox, R. Austin, J. Sturm, Science 304, 987–990 (2004)

    Article  Google Scholar 

  • I. Lauks, Acc. Chem. Res. 31, 317–324 (1998)

    Article  Google Scholar 

  • E. Levy, S. Zanki, H. Walter, Eur. J. Immunol. 11(11), 952–955 (1981)

    Article  Google Scholar 

  • J. Lundahl, G. Hallden, M. Hallgren, C. Skold, J. Hed, J. Immunol. Methods 180, 93–100 (1995)

    Article  Google Scholar 

  • P. Malstrom, A. Jonsson, H. Sjogren, Cell. Immunol. 53(1), 51–64 (1986)

    Article  Google Scholar 

  • R. Meagher, Y. Light, A. Singh, Lab Chip 8(4), 527–532 (2008)

    Article  Google Scholar 

  • J. Michalski, S. Zanki, J. Anderson, H. Walter, J. Clin. Lab. Immunol. 1, 43–48 (1986)

    Google Scholar 

  • K. Nam, W. Chang, H. Hong, S. Lim, D. Kim, Y. Koo, Biomed. Microdevices 7(3), 189–195 (2005)

    Article  Google Scholar 

  • M. Pinilla, J. de la Fuente, A. Garcia-Pirez, P. Jimeno, P. Sancho, J. Luque, J. Chromatogr. A 668(1), 165–171 (1994)

    Article  Google Scholar 

  • P. Sethu, M. Anahtar, L. Moldawer, R. Tompkins, M. Toner, Anal. Chem. 76(2), 6247–6253 (2004)

    Article  Google Scholar 

  • M. Tiirikainen, Cytometry 20(4), 341–348 (1995)

    Article  Google Scholar 

  • M. Toner, D. Irimia, Blood on a chip. Annu. Rev. Biomed. Eng. 7, 77–103 (2005)

    Article  Google Scholar 

  • H. Walter, L. Graham, E. Krob, M. Hill, Biochim. Biophys. Acta 602, 309–322 (1980a)

    Article  Google Scholar 

  • H. Walter, E. Krob, J. Chromatogr. 479:307–317 (1989)

    Article  Google Scholar 

  • H. Walter, E. Krob, D. Brooks, Biochemistry 15(14), 2959–2964 (1976)

    Article  Google Scholar 

  • H. Walter, E. Krob, A. Pedram, Cell Biophys. 4, 273–284 (1982)

    Article  Google Scholar 

  • H. Walter, C. Tamblyn, E. Levy, D. Brooks, G. Seaman, Biochim. Biophys. Acta 598, 193–199 (1980b)

    Article  Google Scholar 

  • H. Walter, T. Webber, J. Michalski, C. McCombs, B. Moncla, E. Krob, L. Graham, J. Immunol. 123(4), 1687–1695 (1979)

    Google Scholar 

  • M. Whitesides, E. Ostuni, S. Takayama, X. Jiang, D. Ingber, Annu. Rev. Biomed. Eng. 3, 335–373 (2001)

    Article  Google Scholar 

  • M. Yamada, V. Kasim, M. Nakashima, J. Edahiro, M. Seki, Biotechnol. Bioeng. 88(4), 489–494 (2004a)

    Article  Google Scholar 

  • M. Yamada, M. Nakashima, M. Seki, Annu. Rev. Biomed. Eng. 76(18), 5465–5471 (2004b)

    Google Scholar 

Download references

Acknowledgements

Funding for this project was provided by the NIH Carolina Center of Cancer Nanotechnology Excellence grant U54 CA119343.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jeffrey R. SooHoo.

Rights and permissions

Reprints and permissions

About this article

Cite this article

SooHoo, J.R., Walker, G.M. Microfluidic aqueous two phase system for leukocyte concentration from whole blood. Biomed Microdevices 11, 323–329 (2009). https://doi.org/10.1007/s10544-008-9238-8

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10544-008-9238-8

Keywords

Navigation