Abstract
Proliferation characteristics of CHO-K1 cells were investigated under a variety of medium perfusion rate conditions in a microfluidic perfusion cell culture platform. Five microcavities of \(800\,\upmu \hbox {m}~(w)\,\times \,800\,\upmu \hbox {m}~(l)\,\times \,400\,\upmu \hbox {m}~(h)\) were adopted in order to minimize or isolate the shear effects on cell surfaces. Microchannels of \(800\,\upmu \hbox {m}~(w)\,\times \,3.5\,\hbox {mm}~(l)\,\times \,100\,\upmu \hbox {m}~(h)\) serially connecting these microcavities created flow contractions and expansions repeatedly, resulting in two different diffusion and convection timescales through the platform. Average shear stresses on the bottom of microcavity were both numerically and analytically estimated, and medium flow was operated at rates where shear stress is below \(\sim\)2 mPa. Proliferation rates of CHO-K1 cells were investigated based both on population groups derived from the number of initially seeded cells and on the microcavity locations. Population groups showed minimal influences on proliferation rates, while proliferation rates increased clearly with medium perfusion rates. Strong effects of microcavity locations were observed on proliferation at \(\hbox {Pe}\,\ge \,45\). Such effects were analyzed by investigating the relationships of reaction, diffusion, and convection timescales associated with perfusion conditions. The ratio of diffusion timescale and convection timescale was suggested as a guideline to estimate the upper limit of perfusion rate in microfluidic perfusion cell culture platform.
Similar content being viewed by others
References
Bacabac RG, Smit TH, Cowin SC, Van Loon JJWA, Nieuwstadt FTM, Heethaar R, Klein-Nulend J (2005) Dynamic shear stress in parallel-plate flow chambers. J Biomech 38(1):159–167
Buchanan CF, Voigt EE, Szot CS, Freeman JW, Vlachos PP, Rylander MN (2014) Three-dimensional microfluidic collagen hydrogels for investigating flow-mediated tumor-endothelial signaling and vascular organization. Tissue Eng Part C: Methods 20(1):64–75
Carraro A, Hsu WM, Kulig KM, Cheung WS, Miller ML, Weinberg EJ, Swart EF, Kaazempur-Mofrad M, Borenstein JT, Vacanti JP, Neville C (2008) In vitro analysis of a hepatic device with intrinsic microvascularbased channels. Biomed Microdevices 10(6):795–805
Cartmell SH, Porter BD, García AJ, Guldberg RE (2003) Effects of medium perfusion rate on cell-seeded three-dimensional bone constructs in vitro. Tissue Eng 9(6):1197–1203
Dånmark S, Gladnikoff M, Frisk T, Zelenina M, Mustafa K, Russom A, Finne-Wistrand A (2012) Development of a novel microfluidic device for long-term in situ monitoring of live cells in 3-dimensional matrices. Biomed Microdevices 14(5):885–893
Dowd J, Jubb A, Kwok KE, Piret J (2003) Optimization and control of perfusion cultures using a viable cell probe and cell specific perfusion rates. Cytotechnology 42(1):35–45
Giulitti S, Magrofuoco E, Prevedello L, Elvassore N (2013) Optimal periodic perfusion strategy for robust long-term microfluidic cell culture. Lab Chip 13(22):4430–4441
Grayson WL, Bhumiratana S, Cannizzaro C, Chao PHG, Lennon DP, Caplan AI, Vunjak-Novakovic G (2008) Effects of initial seeding density and fluid perfusion rate on formation of tissue-engineered bone. Tissue Eng Part A 14(11):1809–1820
Hahn C, Wang C, Orr AW, Coon BG, Schwartz MA (2011) JNK2 promotes endothelial cell alignment under flow. PloS One
Hung PJ, Lee PJ, Sabounchi P, Lin R, Lee LP (2004) Continuous perfusion microfluidic cell culture array for high-throughput cell-based assays. Biotechnol Bioeng 89(1):1–8
Issa RI, Engebretson B, Rustom L, McFetridge PS, Sikavitsas VI (2011) The effect of cell seeding density on the cellular and mechanical properties of a mechanostimulated tissue-engineered tendon. Tissue Eng Part A 17(11–12):1479–1487
Keane JT, Ryan D, Gray PP (2002) Effect of shear stress on expression of a recombinant protein by Chinese hamster ovary cells. Biotechnol Bioeng 81(2):211–220
Kim L, Vahey MD, Lee HY, Voldman J (2006) Microfluidic arrays for logarithmically perfused embryonic stem cell culture. Lab Chip 6(3):394–406
Kim L, Toh YC, Voldman J, Yu H (2007) A practical guide to microfluidic perfusion culture of adherent mammalian cells. Lab Chip 7(6):681–694
Kolnik M, Tsimring LS, Hasty J (2012) Vacuum-assisted cell loading enables shear-free mammalian microfluidic culture. Lab Chip 12(22):4732–4737
Korin N, Bransky A, Khoury M, Dinnar U, Levenberg S (2009) Design of well and groove microchannel bioreactors for cell culture. Biotechnol Bioeng 102(4):1222–1230
Lee PJ, Hung PJ, Rao VM, Lee LP (2006) Nanoliter scale microbioreactor array for quantitative cell biology. Biotechnol Bioeng 94(1):5–14
Linder-Ganz E, Engelberg S, Scheinowitz M, Gefen A (2006) Pressure-time cell death threshold for albino rat skeletal muscles as related to pressure sore biomechanics. J Biomech 39(14):2725–2732
Liu MC, Tai YC (2010) A 3-D microfluidic combinatorial cell array. Biomed Microdevices 13(1):191–201
Malek AM, Izumo S (1996) Mechanism of endothelial cell shape change and cytoskeletal remodeling in response to fluid shear stress. J Cell Sci 109:713–726
Mohamed VP, Hashim Y, Amid A, Mel M (2011) Chinese hamster ovary (CHO-K1) cells expressed native insulin-like growth factor-1 (IGF-1) gene towards efficient mammalian cell culture host system. Afr J Biotechnol 10(81):18,716–18,721
Park J, Berthiaume F, Toner M, Yarmush ML, Tilles AW (2005) Microfabricated grooved substrates as platforms for bioartificial liver reactors. Biotechnol Bioeng 90(5):632–644
Park JY, Yoo SJ, Patel L, Lee SH, Lee SH (2010) Cell morphological response to low shear stress in a two-dimensional culture microsystem with magnitudes comparable to interstitial shear stress. Biorheology 47(3–4):165–178
Polacheck WJ, Li R, Uzel SGM, Kamm RD (2013) Microfluidic platforms for mechanobiology. Lab Chip 13(12):2252–2267
Ranjan V, Waterbury R, Xiao Z (1996) Fluid shear stress induction of the transcriptional activator c-fos in human and bovine endothelial cells, HeLa, and Chinese hamster ovary cells. Biotechnol Bioeng 49(4):383–390
Schwartz RM, Palsson BO, Emerson SG (1991) Rapid medium perfusion rate significantly increases the productivity and longevity of human bone marrow cultures. Proc Natl Acad Sci U S A 88(15):6760–6764
Shiragami N, Unno H (1994) Effect of shear-stress on activity of cellular enzyme in animal-cell. Bioprocess Eng 10(1):43–45
Shiragami N, Oda H, Honda H, UNNO H (1992) Stimulation of animal cell metabolism by shear stress. Anim Cell Technol: Basic Appl Aspects 4:271–277
Tanaka Y, Yamato M, Okano T, Kitamori T, Sato K (2006) Evaluation of effects of shear stress on hepatocytes by a microchip-based system. Meas Sci Technol 17(12):3167–3170
Tsao YS, CardosoAG Condon RGG, Voloch M, Lio P, Lagos JC, Kearns BG, Liu Z (2005) Monitoring Chinese hamster ovary cell culture by the analysis of glucose and lactate metabolism. J Biotechnol 118(3):316–327
Wu SC (1999) Influence of hydrodynamic shear stress on microcarrier-attached cell growth: cell line dependency and surfactant protection. Bioprocess Eng 21(3):201–206
Young EWK, Beebe DJ (2010) Fundamentals of microfluidic cell culture in controlled microenvironments. Chem Soc Rev 39(3):1036–1048
Yu H, Meyvantsson I, Shkel IA, Beebe DJ (2005) Diffusion dependent cell behavior in microenvironments. Lab Chip 5(10):1089–1095
Zhang X, Jones P, Haswell S (2008) Attachment and detachment of living cells on modified microchannel surfaces in a microfluidic-based lab-on-a-chip system. Chem Eng J 135:S82–S88
Ziółkowska K, Kwapiszewski R, Brzózka Z (2011) Microfluidic devices as tools for mimicking the in vivo environment. New J Chem 35(5):979–990
Acknowledgments
This work was supported by the KIST Institutional Program (2E24700) and by Convergence Technology Development Program (S2096502) of Small and Medium Business Administration of Korea. S. Chung was supported by NRF (2012-022481) and Human Energy, Republic of Korea (20124010203250).
Author information
Authors and Affiliations
Corresponding author
Electronic supplementary material
Below is the link to the electronic supplementary material.
Rights and permissions
About this article
Cite this article
Maeng, JH., Jeong, H.E., Shin, HJ. et al. Timescale analysis for estimating upper limit perfusion rate in a microfluidic perfusion cell culture platform. Microfluid Nanofluid 19, 777–786 (2015). https://doi.org/10.1007/s10404-015-1602-4
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10404-015-1602-4