Abstract
The nanointerstices (NIs) at the sidewalls of a microfluidic channel impose a strong driving force on the main flow and render the flow less dependent on the surface contact angle of the microfluidic channel. NIs facilitate rapid and stable filling of aqueous solutions in plastic microfluidic channels and have been widely applied to many commercial applications. However, the air–liquid interface in an NI-driven microflow can be disrupted by small defects in the NIs, and bubbles can form around the defects. Here, we analyze the effects of the heterogeneous contact angle and the structural interrupts on the NI-driven microflow. We also formulated a mathematical model that precisely calculated the interrupted NI-driven microflow profile. From this study, the NI-driven microflow is anticipated to further facilitate commercial applications by providing reliable microfluidic channels and offering robust NI-driven microflow with perfect initial filling, a symmetric front meniscus, and the avoidance of bubble generation.
References
Chung S, Yun H, Kamm RD (2009) Nanointerstice-driven microflow. Small 5:609–613
Hartwell SK, Wannaprom N, Kongtawelert P, Grudpan K (2009) Sequential injection-capillary immunoassay system for determination of sialoglycoconjugates. Talanta 79:1209–1215
Huang Y, Tang J (2009) Research on DNA fluorescence capillary biosensor marked by goldview. Spectrosc Spectr Anal 29:165–168
Kohonen MM (2006) Engineered wettability in tree capillaries. Langmuir 22:3148–3153
Kohonen MM, Helland Å (2009) On the function of wall sculpturing in xylem conduits. J Bionic Eng 6:324–329
Li Y-S, Du Y-D, Chen T-M, Gao X-F (2010a) A novel immobilization multienzyme glucose fluorescence capillary biosensor. Biosens Bioelectron 25:1382–1388
Li J, Zou Y, Cheng L (2010b) Experimental study on capillary pumping performance of porous wicks for loop heat pipe. Exp Therm Fluid Sci 34:1403–1408
Nobel PS (2005) Physicochemical and environmental plant physiology. Academic Press, San Diego
O’Carroll DM, Mumford KG, Abriola LM, Gerhard JI (2010) Influence of wettability variations on dynamic effects in capillary pressure. Water Resour Res 46. doi:10.1029/2009WR008712
Thomas T, Riley L, Grant D, Grant SA (2007) Development of a capillary biosensor for Helicobacter hepaticus. Sens Lett 5:398–404
Wei R, He Y, Wang X, Keller P (2013) Nematic liquid crystalline elastomer grating and microwire fabricated by micro‐molding in capillaries. Macromol Rapid Commun 34:330–334
Wild D (2005) The immunoassay handbook. Gulf Professional Publishing, Houston
Wolf M, Zimmermann M, Delamarche E, Hunziker P (2007) Screening cell surface receptors using micromosaic immunoassays. Biomed Microdevices 9:135–141
Yang L et al (2005) Gold nanoparticle-modified etched capillaries for open-tubular capillary electrochromatography. Anal Chem 77:1840–1846
Zhang X, Zhang Z (2013) Capillary electrophoresis-based immunoassay for the determination of brevetoxin-B in shellfish using electrochemical detection. J Chromatogr Sci 51:107–111
Zimmermann MH (1983) Xylem structure and the ascent of sap. Springer, Berlin
Acknowledgments
This work was supported by grants from the Korea Ministry of Environment, as part of the Projects for Developing Eco-Innovation Technologies (GT-11-G-02-001-1) and by BioNano Health-Guard Research Center funded by the Ministry of Science, ICT and Future Planning (MSIP) of Korea as Global Frontier Project (Grant Number H-GUARD_2014M3A6B2060524).
Author information
Authors and Affiliations
Corresponding author
Additional information
Junghyun Kim and Sewoon Han have contributed equally to this manuscript.
Electronic supplementary material
Below is the link to the electronic supplementary material.
Rights and permissions
About this article
Cite this article
Kim, J., Han, S., Yoon, J. et al. Nanointerstice-driven microflow patterns in physical interrupts. Microfluid Nanofluid 18, 1433–1438 (2015). https://doi.org/10.1007/s10404-014-1513-9
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10404-014-1513-9