Abstract
The orientation of cells and associated F-actin stress fibers is essential for proper tissue functioning. We have previously developed a computational model that qualitatively describes stress fiber orientation in response to a range of mechanical stimuli. In this paper, the aim is to quantitatively validate the model in a static, heterogeneous environment. The stress fiber orientation in uniaxially and biaxially constrained microscale tissues was investigated using a recently developed experimental system. Computed and experimental stress fiber orientations were compared, while accounting for changes in orientation with location in the tissue. This allowed for validation of the model, and additionally, it showed how sensitive the stress fiber orientation in the experimental system is to the location where it is measured, i.e., the heterogeneity of the stress fiber orientation. Computed and experimental stress fiber orientations showed good quantitative agreement in most regions. A strong local alignment near the locations where boundary conditions were enforced was observed for both uniaxially and biaxially constrained tissues. Excepting these regions, in biaxially constrained tissues, no preferred orientation was found and the distribution was independent of location. The stress fiber orientation in uniaxially constrained tissues was more heterogeneous, and stress fibers mainly oriented in the constrained direction or along the free edge. These results indicate that the stress fiber orientation in these constrained microtissues is mainly determined by the local mechanical environment, as hypothesized in our model, and also that the model is a valid tool to predict stress fiber orientation in heterogeneously loaded tissues.
Similar content being viewed by others
References
Birk DE, Trelstad RL (1984) Extracellular compartments in matrix morphogenesis: collagen fibril, bundle, and lamellar formation by corneal fibroblasts. J Cell Biol 99(6):2024–2033
Chiron S, Tomczak C, Duperray A, Lainé J, Bonne G, Eder A, Hansen A, Eschenhagen T, Verdier C, Coirault C (2012) Complex interactions between human myoblasts and the surrounding 3D fibrin-based matrix. PLoS ONE 7(4):e36173. doi:10.1371/journal.pone.0036173
Deshpande VS, McMeeking RM, Evans AG (2006) A bio-chemo-mechanical model for cell contractility. Proc Natl Acad Sci USA 103(38):14015–14020. doi:10.1073/pnas.0605837103
de Jonge N, Kanters FMW, Baaijens FPT, Bouten CVC (2013) Strain-induced collagen organization at the micro-level in fibrin-based engineered tissue constructs. Ann Biomed Eng 41(4):763–774. doi:10.1007/s10439-012-0704-3
Driessen NJB, Mol A, Bouten CVC, Baaijens FPT (2007) Modeling the mechanics of tissue-engineered human heart valve leaflets. J Biomech 40(2):325–334. doi:10.1016/j.jbiomech.2006.01.009
Foolen J, Deshpande VS, Kanters FMW, Baaijens FPT (2012) The influence of matrix integrity on stress-fiber remodeling in 3D. Biomaterials 33(30):7508–7518. doi:10.1016/j.biomaterials.2012.06.103
Frangi AF, Niessen WJ, Vincken KL, Viergever MA (1998) Multiscale vessel enhancement filtering. In: Wells WM, Colchester A, Delp SL (eds) Med Image Comput Comput Interv - MICCAI’98, Springer, Berlin Heidelberg, pp 130–137, doi:10.1007/BFb0056195
Gauvin R, Parenteau-Bareil R, Larouche D, Marcoux H, Bisson F, Bonnet A, Auger FA, Bolduc S, Germain L (2011) Dynamic mechanical stimulations induce anisotropy and improve the tensile properties of engineered tissues produced without exogenous scaffolding. Acta Biomater 7(9):3294–3301. doi:10.1016/j.actbio.2011.05.034
Gould RA, Chin K, Santisakultarm TP, Dropkin A, Richards JM, Schaffer GB, Butcher JT (2012) Cyclic strain anisotropy regulates valvular interstitial cell phenotype and tissue remodeling in three-dimensional culture. Acta Biomater 8(5):1710–1719
Henshaw DR, Attia E, Bhargava M, Hannafin JA (2006) Canine ACL fibroblast integrin expression and cell alignment in response to cyclic tensile strain in three-dimensional collagen gels. J Orthop Res 24(3):481–490
Hu S, Eberhard L, Love JC, Butler JP, Fredberg JJ, Whitesides GM, Wang N (2004) Mechanical anisotropy of adherent cells probed by a three-dimensional magnetic twisting device. Am J Physiol Cell Physiol 287(5):1184–1191
Jungbauer S, Gao H, Spatz JP, Kemkemer R (2008) Two characteristic regimes in frequency-dependent dynamic reorientation of fibroblasts on cyclically stretched substrates. Biophys J 95(7):3470–3478. doi:10.1529/biophysj.107.128611
Lebedev VI, Laikov DN (1999) A quadrature formula for the sphere of the 131st algebraic order of accuracy. Doklady Mathematics 59(3):477–481
Legant WR, Pathak A, Yang MT, Deshpande VS, McMeeking RM, Chen CS (2009) Microfabricated tissue gauges to measure and manipulate forces from 3D microtissues. Proc Natl Acad Sci USA 106(25):10097–10102. doi:10.1073/pnas.0900174106
Nieponice A, Maul TM, Cumer JM, Soletti L, Vorp DA (2007) Mechanical stimulation induces morphological and phenotypic changes in bone marrow-derived progenitor cells within a three-dimensional fibrin matrix. J Biomed Mater Res A 81(3):523–530. doi:10.1002/jbm.a.31041
Obbink-Huizer C, Oomens CWJ, Loerakker S, Foolen J, Bouten CVC, Baaijens FPT (2014) Computational model predicts cell orientation in response to a range of mechanical stimuli. Biomech Model Mechanobiol 13(1):227–236 doi:10.1007/s10237-013-0501-4
Wang JHC, Jia F, Gilbert TW, Woo SLY (2003) Cell orientation determines the alignment of cell-produced collagenous matrix. J Biomech 36(1):97–102
Zemel A, Rehfeldt F, Brown AEX, Discher DE, Safran SA (2010) Optimal matrix rigidity for stress fiber polarization in stem cells. Nat Phys 6(6):468–473. doi:10.1038/nphys1613
Acknowledgments
The authors thank F.M.W. Kanters for his contribution to the image processing algorithm. This research forms part of the Project P1.04 SMARTCARE of the research program of the BioMedical Materials institute, co-funded by the Dutch Ministry of Economic Affairs. The financial contribution of the Nederlandse Hartstichting is gratefully acknowledged.
Author information
Authors and Affiliations
Corresponding author
Electronic supplementary material
Below is the link to the electronic supplementary material.
Rights and permissions
About this article
Cite this article
Obbink-Huizer, C., Foolen, J., Oomens, C.W.J. et al. Computational and experimental investigation of local stress fiber orientation in uniaxially and biaxially constrained microtissues. Biomech Model Mechanobiol 13, 1053–1063 (2014). https://doi.org/10.1007/s10237-014-0554-z
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10237-014-0554-z