Abstract
This study aims to correlate coronary artery enhancement levels with quality of vessel visualization and calcified plaque visualization using a 128-slice dual-source CT (DSCT) scanner. Coronary CT angiography exams from 52 patients, mean age of 55 years (range, 22–90) and mean weight of 184 lbs (range, 120–320 lbs), were reviewed retrospectively. Contrast infusion rates ranged from 4.5 to 7 mL/s (mean, 5.8 mL/s). Postcontrast density of the largest calcified plaque and postcontrast density of the left main (LM) and right coronary arteries (RCA) were recorded. Enhancement quality was graded as 1 = suboptimal, 2 = adequate for diagnosis, and 3 = excellent. Pre- and postcontrast acquisitions were compared for calcified plaque conspicuity. The largest calcified plaque density was a mean of 862 HU (range, 376 to 1,384 HU) on the postcontrast scan. The mean LM and RCA coronary artery enhancement levels for studies of excellent enhancement quality (N = 43) were 468 and 457 HU, respectively, higher than mean enhancement levels of 320 and 322 HU for adequate enhancement quality (N = 8) (p < 0.0001 and 0.009). One study was graded as a nondiagnostic enhancement quality. Twenty-five subjects had calcified plaque, 3/8 with adequate and 22/43 with excellent enhancement quality. At least one calcified plaque measuring <2 mm was isodense to contrast enhancement on axial images in 5/25; all five were in the highest enhancement quality group. High coronary artery enhancement quality using 128-DSCT is associated with mean proximal coronary artery enhancement levels over 400 HU. High levels of enhancement may obscure small, calcified plaques.
Similar content being viewed by others
References
Burgstahler C, Reimann A, Brodoefel H, Daferner U, Herberts T, Tsiflikas I, Thomas C, Drosch T, Schroeder S, Heuschmid M (2009) Quantitative parameters to compare image quality of non-invasive coronary angiography with 16-slice, 64-slice and dual-source computed tomography. Eur Radiol 19:584–590
Donnino R, Jacobs JE, Doshi JV, Hecht EM, Kim DC, Babb JS, Srichai MB (2009) Dual-source versus single-source cardiac CT angiography: comparison of diagnostic image quality. AJR 192:1051–1056
Pannu HK, Johnson PT, Fishman EK (2009) 64 Slice multi-detector row cardiac CT. Emerg Radiol 16:1–10
Achenbach S, Goroll T, Seltmann M, Pflederer T, Anders K, Ropers D, Daniel WG, Uder M, Lell M, Marwan M (2011) Detection of coronary artery stenoses by low-dose, prospectively ECG-triggered, high-pitch spiral coronary CT angiography. JACC Cardiovasc Imaging 4:328–337
Becker CR, Hong C, Knez A, Leber A, Bruening R, Schoepf UJ, Reiser MF (2003) Optimal contrast application for cardiac 4-detector-row computed tomography. Investig Radiol 38:690–694
Cademartiri F, Maffei E, Palumbo AA, Malago R, La Grutta L, Meiijboom WB, Aldrovandi A, Fusaro M, Vignali L, Menozzi A, Brambilla V, Coruzzi P, Midiri M, Kirchin MA, Mollet NR, Krestin GP (2008) Influence of intra-coronary enhancement on diagnostic accuracy with 64-slice CT coronary angiography. Eur Radiol 18:576–583
Stolzmann P, Leschka S, Scheffel H, Krauss T, Desbiolles L, Plass A, Genoni M, Flohr TG, Wildermuth S, Marincek B, Alkadhi H (2008) Dual-source CT in step-and-shoot mode: noninvasive coronary angiography with low radiation dose. Radiology 249:71–80
Weininger M, Barraza JM, Kemper CA, Kalafut JF, Costello P, Schoepf UJ (2011) Cardiothoracic CT angiography: current contrast medium delivery strategies. AJR 196:W260–W72
Johnson TR, Nikolaou K, Wintersperger BJ, Fink C, Rist C, Leber AW, Knez A, Reiser MF, Becker CR (2007) Optimization of contrast material administration for electrocardiogram-gated computed tomographic angiography of the chest. J Comput Assist Tomogr 31:265–271
Conflict of Interest
The authors declare that they have no conflict of interest.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Malayeri, A.A., Zimmerman, S.L., Lake, S.T. et al. 128-Slice dual source coronary CTA: defining optimal arterial enhancement levels. Emerg Radiol 21, 499–504 (2014). https://doi.org/10.1007/s10140-014-1214-4
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10140-014-1214-4