Abstract
The purpose of this study was to observe variation in the local elastic distribution in aortic tissue walls under different static strain conditions, including physiological strain, by use of a scanning haptic microscope (SHM). Strain was applied by stretching aortic tissues in the circumferential direction by the simple tensile method or by the rod-insertion method to mimic in vivo internal pressure loading. SHM measurements in a saline solution at room temperature were performed on canine thoracic aorta using a glass needle probe with a diameter of ca 5 μm and a scanning area and point pitch of 160 × 80 μm and 2 μm, respectively. Under strain of 0–0.23, corresponding to internal pressure of 0–150 mmHg, wavy-shaped elastin fibers stretched until they were almost straightened, and the average elastic modulus increased almost linearly. Although there was little difference between the images obtained for the two different stretching methods, under high strain (>0.36; 250 mmHg) significant circumferential orientation of the collagen fibrils occurred with an increase in the average elastic modulus. It was concluded that the pressure resistance of the aorta under physiological strain was mainly afforded by elastin fibers; collagen fibrils contributed little except under much higher pressures.
Similar content being viewed by others
References
Litwin SB, Cohen J, Fine S. Effects of sterilization and preservation on the rupture force and tensile strength of canine aortic tissue. J Surg Res. 1973;15:198–206.
Assoul N, Flaud P, Chaouat M, Letourneur D, Bataille I. Mechanical properties of rat thoracic and abdominal aortas. J Biomech. 2008;41:2227–36.
Angouras DC, Dosios TJ, Dimitriou CA, Chamogeorgakis TP, Rokkas CK, Manos TA, Sokolis DP. Surgical thoracic sympathectomy induces structural and biomechanical remodeling of the thoracic aorta in a porcine model. J Surg Res. 2012;172:68–76.
Wolinsky H, Glagov S. Structural basis for the static mechanical properties of the aortic media. Circ Res. 1964;14:400–13.
Hayashi K, Handa H, Nagasawa S, Okumura A, Moritake K. Stiffness and elastic behavior of human intracranial and extracranial arteries. J Biomech. 1980;13:175–84.
Dobrin PB, Rovick AA. Influence of vascular smooth muscle on contractile mechanics and elasticity of arteries. Am J Physiol. 1969;217:1644–51.
Vaishnav RN, Young JT, Patel DJ. Distribution of stresses and of strain-energy density through the wall thickness in a canine aortic segment. Circ Res. 1973;32:577–83.
Matsumoto T, Hayashi K. Stress and strain distribution in hypertensive and normotensive rat aorta considering residual strain. J Biomech Eng. 1996;118:62–73.
Binnig G, Quate CF, Gerber C. Atomic force microscope. Phys Rev Lett. 1986;56:930–3.
Zhang Y, Hu X, Sun J, Shen Y, Hu J, Xu X, Shao Z. High-resolution imaging and nano-manipulation of biological structures on surface. Microsc Res Tech. 2011;74:614–26.
Yang L, van der Werf KO, Koopman BF, Subramaniam V, Bennink ML, Dijkstra PJ, Feijen J. Micromechanical bending of single collagen fibrils using atomic force microscopy. J Biomed Mater Res A. 2007;82:160–8.
Ohashi T, Kato Y, Matsumoto T, Sato M. Intramural distribution of elastic moduli in thoracic aortas and its relationship to histology: comparison between porcine and bovine thoracic aortas. JSME Int J Ser C. 1999;42:568–73.
Kanai H, Hasegawa H, Ichiki M, Tezuka F, Koiwa Y. Elasticity imaging of atheroma with transcutaneous ultrasound: preliminary study. Circulation. 2003;107:3018–21.
Kim K, Jeong CG, Hollister SJ. Non-invasive monitoring of tissue scaffold degradation using ultrasound elasticity imaging. Acta Biomater. 2008;4:783–90.
Matsumoto T, Goto T, Furukawa T, Sato M. Residual stress and strain in the lamellar unit of the porcine aorta: experiment and analysis. J Biomech. 2004;37:807–15.
Tracqui P, Broisat A, Toczek J, Mesnier N, Ohayon J, Riou L. Mapping elasticity moduli of atherosclerotic plaque in situ via atomic force microscopy. J Struct Biol. 2011;174:115–23.
Murayama Y, Omata S. Fabrication of micro tactile sensor for the measurement of micro-scale local elasticity. Sens Actuators A. 2004;109:202–7.
Murayama Y, Constantinou CE, Omata S. Micro-mechanical sensing platform for the characterization of the elastic properties of the ovum via uniaxial measurement. J Biomech. 2004;37:67–72.
Murayama Y, Constantinou CE, Omata S. Development of tactile mapping system for the stiffness characterization of tissue slice using novel tactile sensing technology. Sens Actuators A. 2005;120:543–9.
Oie T, Suzuki H, Murayama Y, Fukuda T, Omata S, Kanda K, Takamizawa K, Nakayama Y. Surface elasticity imaging of vascular tissues in a liquid environment by a scanning haptic microscope. J Artif Organs. 2010;13:121–5.
Moriwaki T, Oie T, Takamizawa K, Murayama Y, Fukuda T, Omata S, Kanda K, Nakayama Y. Variations in local elastic modulus along the length of the aorta as observed by use of a scanning haptic microscope (SHM). J Artif Organs. 2011;14:276–83.
Omata S, Terunuma Y. New tactile sensor like the human hand and its application. Sens Actuators A. 1992;35:9–15.
Takamizawa K, Hayashi K. Strain energy density function and uniform strain hypothesis for arterial mechanics. J Biomech. 1987;20:7–17.
Gosline J, Lillie M, Carrington E, Guerette P, Ortlepp C, Savage K. Elastic proteins: biological roles and mechanical properties. Philos Trans R Soc Lond B Biol Sci. 2002;357:121–32.
Matsumoto T, Sato M. Analysis of stress and strain distribution in the artery wall consisted of layers with different elastic modulus and opening angle. JSME Int J Ser C. 2002;45:906–12.
Acknowledgments
The authors thank Ms Manami Sone for her technical support in this study. This study was funded in part by a Grant-in-Aid for Scientific Research (B2465961, B23360374) from the Ministry of Education, Culture, Sports, Science and Technology of Japan.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Moriwaki, T., Oie, T., Takamizawa, K. et al. Observation of local elastic distribution in aortic tissues under static strain condition by use of a scanning haptic microscope. J Artif Organs 16, 91–97 (2013). https://doi.org/10.1007/s10047-012-0674-0
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10047-012-0674-0