Abstract
We propose a simple method to modulate spatial interferogram to achieve full-range complex imaging in Fourier-domain optical coherence tomography, in which a sample stage is employed which can be adjusted to introduce a constant carrier frequency into the interference signal during the B-scan by adjusting the stage angle with respect to the normal to the object under test. An additional phase, which is linearly related to the lateral position, is then induced in the A-scan. The in vivo images of human skin were generated which demonstrate that the method proposed can generate the cross-sectional image with the same quality with that obtained with other methods and with the advantage of the simplicity in implementation.
Similar content being viewed by others
References
Hee, M.R., Izatt, J.A., Swanson, E.A., Huang, D., Lin, C.P., Schuman, J.S., Puliafito, C.A., Fujimoto, J.G.: Optical coherence tomography of the human retina. Arch. Ophthalmol. 113, 325–332 (1995)
Fujimoto, J.G., Brezinski, M.E., Tearney, G.J., Boppart, S.A., Bouma, B.E., Hee, M.R., Southern, J.F., Swanson, E.A.: Optical biopsy and imaging using optical coherence tomography. Nat. Med. 1(9), 970–972 (1995)
Tearney, G.J., Boppart, S.A., Bouma, B.E., Brezinski, M.E., Weissmann, N.J., Southern, J.F., Fujimoto, J.G.: Scanning single-mode fiber optic catheter-endoscope for optical coherence tomography. Opt. Lett. 21, 543–545 (1996)
Leitgeb, R.A., Hitzenberger, C.K., Fercher, A.F.: Performance of fourier domain versus time domain optical coherence tomography. Opt. Express 11(8), 889–894 (2003)
Choma, M.A., Kowalczyk, A., Yang, C., Izatt, J.A.: Sensitivity advantage of swept source and Fourier domain optical coherence tomography. Opt. Express 11(18), 2183–2189 (2003)
Hausler, G., Lindner, M.W.: Coherence radar and spectral radar-new tools for dermatological diagnosis. J. Biomed. Optics 3(1), 21–31 (1998)
Wojtkowski, M., Kowalczyk, A., Leitgeb, R., Fercher, A.F.: Full range complex spectral optical coherence tomography technique in eye imaging. Opt. Lett. 27(16), 1415–1417 (2002)
Sarunic, M.V., Choma, M.A., Yang, C.H., Izatt, J.A.: Instantaneous complex conjugate resolved spectral domain and swept-source OCT using 3 × 3 fiber couplers. Opt. Express 13(3), 957–967 (2005)
Marques, M.J., Bradu, A., Podoleanu, A.G.: Towards simultaneous Talbot bands based optical coherence tomography and scanning laser ophthalmoscopy imaging. Biomed. Optics Express 5(5), 1428–1444 (2014)
Wang, R.K.: In vivo full range complex Fourier domain optical coherence tomography. Appl. Phys. Lett. 90(5), 054103 (2007)
Yasuno, Y., Majita, S., Endo, T., Aoki, G., Itoh, M., Yatagai, T.: Simultaneous B-M-mode scanning method for real-time full-range Fourier domain optical coherence tomography. Appl. Opt. 45(8), 1861–1865 (2006)
An, L., Wang, R.K.: Use of a scanner to modulate spatial interferograms for in vivo full-range Fourier-domain optical coherence tomography. Opt. Lett. 32(23), 3423–3425 (2007)
Baumann, B., Pircher, M., Gotzinger, E., Hitzenberger, C.K.: Full range complex spectral domain optical coherence tomography without additional phase shifters. Opt. Express 15(20), 13375–13387 (2007)
Acknowledgments
This research was supported by the National Natural Science Foundation of China (61275198, 60978069).
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Bian, H., Gao, W. Stage-based frequency-modulated full-range complex Fourier-domain optical coherence tomography . Opt Rev 22, 700–705 (2015). https://doi.org/10.1007/s10043-015-0126-1