A 55-year-old man presented with a massive hemorrhage from the ileal conduit of the left ureter. He had previously undergone a total pelvic exenteration with ileal conduit construction of the ureters due to rectal carcinoma. A right ureteroarterial fistula developed, and he underwent an excision of the right common iliac artery with a femorofemoral bypass and a right cutaneous ureterostomy. Seven months later, a pseudoaneurysm developed at the aortic stump, followed by an aorto-ileal-conduit fistula. The patient was treated successfully with endovascular stent grafting and has since showed a good recovery no sign of graft infection or a recurrence of hematuria at the 10-month follow-up.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. SJ Batter FJ McGovern RP Cambria (1996) ArticleTitleUreteroarterial fistula: case report and review of the literature Urology 48 481–9 Occurrence Handle8804509 Occurrence Handle10.1016/S0090-4295(96)00202-6 Occurrence Handle1:STN:280:DyaK28zpslKitw%3D%3D

    Article  PubMed  CAS  Google Scholar 

  2. SP Quillin MD Darcy D Picus (1994) ArticleTitleAngiographic evaluation and therapy of ureteroarterial fistulas AJR 162 873–8 Occurrence Handle8141010 Occurrence Handle1:STN:280:DyaK2c7ovFCitA%3D%3D

    PubMed  CAS  Google Scholar 

  3. SE Georgopoulos DP Arvanitis P Tekerlekis A Chronopoulos A Konstakopoulos (2003) ArticleTitleRupture of an aortic anastomotic aneurysm into a ureter Urol Int 71 333–5 Occurrence Handle14512661 Occurrence Handle10.1159/000072692 Occurrence Handle1:STN:280:DC%2BD3svltFCntQ%3D%3D

    Article  PubMed  CAS  Google Scholar 

  4. M Holmes N Hung M Hunter (1998) ArticleTitleHematuria and death secondary to aortoureteric fistula Urology 52 720–2 Occurrence Handle9763104 Occurrence Handle10.1016/S0090-4295(98)00281-7 Occurrence Handle1:STN:280:DyaK1cvjsVSlug%3D%3D

    Article  PubMed  CAS  Google Scholar 

  5. T Ota Y Tsuji R Kawasaki T Taniguchi Y Morimoto Y Okita (2005) ArticleTitleEndovascular treatment of aortoureteric fistula J Endovasc Ther 12 411–3 Occurrence Handle15943520 Occurrence Handle10.1583/04-1496.1

    Article  PubMed  Google Scholar 

  6. SF Keller RE Barton WD Routh GM Gross (1990) ArticleTitleGross hematuria in two patients with ureteral-ileal conduits and double-J stents J Vasc Interv Radiol 1 69–79 Occurrence Handle2134038 Occurrence Handle1:STN:280:DyaK387ot1Cktg%3D%3D Occurrence Handle10.1016/S1051-0443(90)72505-5

    Article  PubMed  CAS  Google Scholar 

  7. EH Asham M Walsh M Adisenshiah (1999) ArticleTitleAn unusual case of haematuria treated by endoluminal repair Eur J Vasc Endovasc Surg 17 89–90 Occurrence Handle10071625 Occurrence Handle10.1053/ejvs.1998.0673 Occurrence Handle1:STN:280:DyaK1M7ntFSiuw%3D%3D

    Article  PubMed  CAS  Google Scholar 

  8. T Miyata N Ohara H Shigematsu T Konishi H Yamaguchi S Kazama et al. (1999) ArticleTitleEndovascular stent graft repair of aortopulmonary fistula J Vasc Surg 29 557–60 Occurrence Handle10069922 Occurrence Handle10.1016/S0741-5214(99)70286-7 Occurrence Handle1:STN:280:DyaK1M7mvFaltw%3D%3D

    Article  PubMed  CAS  Google Scholar 

  9. JH Yoo CT Lee YS Shim JW Chung H Ahn KW Kim (2001) ArticleTitleAortobronchial fistula presenting as recurrent hemoptysis and successfully treated with an endovascular stent graft Respiration 68 537–9 Occurrence Handle11694820 Occurrence Handle10.1159/000050565 Occurrence Handle1:STN:280:DC%2BD3Mnkt1Sgsg%3D%3D

    Article  PubMed  CAS  Google Scholar 

  10. JA Gonzalez-Fajardo V Gutierrez M Martin-Pedrosa S Carrera C Vaquero (2005) ArticleTitleEndovascular repair in the presence of aortic infection Ann Vasc Surg 19 94–8 Occurrence Handle15714375 Occurrence Handle10.1007/s10016-004-0144-0

    Article  PubMed  Google Scholar 

  11. TAM Chuter GC Lukaszewicz LM Reilly RK Kerlan R Faruqi R Sawhney et al. (2000) ArticleTitleEndovascular repair of a presumed aortoenteric fistula: late failure due to recurrent infection J Endovasc Ther 7 240–4 Occurrence Handle10883963 Occurrence Handle10.1583/1545-1550(2000)007<0240:EROAPA>2.3.CO;2 Occurrence Handle1:STN:280:DC%2BD3M%2Fhs1ymuw%3D%3D

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Ishibashi, H., Ohta, T., Sugimoto, I. et al. Successful Treatment of an Aorto-Ileal-Conduit Fistula with an Endovascular Stent Graft: Report of a Case. Surg Today 37, 305–307 (2007). https://doi.org/10.1007/s00595-006-3402-7

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00595-006-3402-7

Key words

Navigation