Skip to main content

Advertisement

Log in

Management of acute unstable distal clavicle fracture with a modified coracoclavicular stabilization technique using a bidirectional coracoclavicular loop system

  • Original Article • SHOULDER - FRACTURES
  • Published:
European Journal of Orthopaedic Surgery & Traumatology Aims and scope Submit manuscript

Abstract

Background

Fracture of the distal clavicle is not uncommon. Despite the vast literature available for the management of this fracture, there is no consensus regarding the gold standard treatment for this fracture.

Purpose

To assess the clinical and radiographic outcomes and complications of acute unstable distal clavicle fracture when treated by a modified coracoclavicular stabilization technique using a bidirectional coracoclavicular loop system.

Methods

Thirty-nine patients (32 males, 7 females) with acute unstable distal clavicle fractures treated by modified coracoclavicular stabilization using the surgical technique of bidirectional coracoclavicular (CC) loops seated behind the coracoacromial (CA) ligament were retrospectively reviewed. Mean follow-up time was 35.7 months (range 24–47 months). The outcomes measured included union rate, union time, CC distances when compared to the patients’ uninjured shoulders, and the Constant and ASES shoulder scores, which were evaluated 6 months after surgery.

Results

All fractures displayed clinical union within 13 weeks postoperatively. The mean union time was 9.2 weeks (range 7–13 weeks). At the time of union, the CC distances on the affected shoulders were on average 0.9 mm (range 0–1.6 mm) longer than the unaffected shoulders. At 6 months after surgery, the Constant and ASES scores were on average 93.4 (72–100) and 91.5 (75–100), respectively. No complications related to the fixation loops, musculocutaneous nerve injuries, or fractures of coracoid or clavicle were recorded. One case of surgical wound dehiscence was observed due to superficial infection. Enlargement of the clavicle drill hole without migration of the buttons was observed in 9 out of 16 cases at a follow-up time of at least 30 months after the original operation.

Conclusions

Modified CC stabilization using bidirectional CC loops seated behind the CA ligament is a simple surgical technique that naturally restores stability to the distal clavicle fracture. It also produces predictable outcomes, a high union rate, good to excellent shoulder function, and a low complication rate. The buttons and suture loops were routinely removed in a second operation in order to prevent late stress fracture of the clavicle.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Nordqvist A, Petersson C (1994) The incidence of fractures of the clavicle. Clin Orthop Relat Res 300:127–132

    PubMed  Google Scholar 

  2. Herscovici D Jr, Sanders R, DiPasquale T, Gregory P (1995) Injuries of the shoulder girdle. Clin Orthop Relat Res 318:54–60

    PubMed  Google Scholar 

  3. Neer CS 2nd (1963) Fracture of the distal clavicle with detachment of the coracoclavicular ligaments in adults. J Trauma 3:99–110

    Article  PubMed  Google Scholar 

  4. Neer CS 2nd (1968) Fractures of the distal third of the clavicle. Clin Orthop Relat Res 58:43–50

    PubMed  Google Scholar 

  5. Robinson CM, Cairns DA (2004) Primary nonoperative treatment of displaced lateral fractures of the clavicle. J Bone Joint Surg 86-A(4):778–782

    PubMed  Google Scholar 

  6. Edwards DJ, Kavanagh TG, Flannery MC (1992) Fractures of the distal clavicle: a case for fixation. Injury 23(1):44–46

    Article  CAS  PubMed  Google Scholar 

  7. Anderson K (2003) Evaluation and treatment of distal clavicle fractures. Clin Sports Med 22(2):319–326 (vii)

    Article  PubMed  Google Scholar 

  8. Webber MC, Haines JF (2000) The treatment of lateral clavicle fractures. Injury 31(3):175–179

    Article  CAS  PubMed  Google Scholar 

  9. Oh JH, Kim SH, Lee JH, Shin SH, Gong HS (2011) Treatment of distal clavicle fracture: a systematic review of treatment modalities in 425 fractures. Arch Orthop Trauma Surg 131(4):525–533

    Article  PubMed  Google Scholar 

  10. Banerjee R, Waterman B, Padalecki J, Robertson W (2011) Management of distal clavicle fractures. J Am Acad Orthop Surg 19(7):392–401

    PubMed  Google Scholar 

  11. Flinkkila T, Ristiniemi J, Lakovaara M, Hyvonen P, Leppilahti J (2006) Hook-plate fixation of unstable lateral clavicle fractures: a report on 63 patients. Acta Orthop 77(4):644–649

    Article  PubMed  Google Scholar 

  12. Kona J, Bosse MJ, Staeheli JW, Rosseau RL (1990) Type II distal clavicle fractures: a retrospective review of surgical treatment. J Orthop Trauma 4(2):115–120

    Article  CAS  PubMed  Google Scholar 

  13. Sambandam B, Gupta R, Kumar S, Maini L (2014) Fracture of distal end clavicle: a review. J Clin Orthop Trauma 5(2):65–73

    Article  PubMed Central  PubMed  Google Scholar 

  14. Lyons FA, Rockwood CA Jr (1990) Migration of pins used in operations on the shoulder. J Bone Joint Surg Am 72(8):1262–1267

    CAS  PubMed  Google Scholar 

  15. Post M (1989) Current concepts in the treatment of fractures of the clavicle. Clin Orthop Relat Res 245:89–101

    PubMed  Google Scholar 

  16. Sajid S, Fawdington R, Sinha M (2012) Locking plates for displaced fractures of the lateral end of clavicle: potential pitfalls. Int J Shoulder Surg 6(4):126–129

    Article  PubMed Central  PubMed  Google Scholar 

  17. Stegeman SA, Nacak H, Huvenaars KH, Stijnen T, Krijnen P, Schipper IB (2013) Surgical treatment of Neer type-II fractures of the distal clavicle: a meta-analysis. Acta Orthop 84(2):184–190

    Article  PubMed Central  PubMed  Google Scholar 

  18. Constant CR, Murley AH (1987) A clinical method of functional assessment of the shoulder. Clin Orthop Relat Res 214:160–164

    PubMed  Google Scholar 

  19. Kirkley A, Griffin S, Dainty K (2003) Scoring systems for the functional assessment of the shoulder. Arthrosc J Arthrosc Relat Surg Off Publ Arthrosc Assoc N Am Int Arthrosc Assoc 19(10):1109–1120

    Article  Google Scholar 

  20. Clavert P, Lutz JC, Wolfram-Gabel R, Kempf JF, Kahn JL (2009) Relationships of the musculocutaneous nerve and the coracobrachialis during coracoid abutment procedure (Latarjet procedure). Surg Radiol Anat SRA 31(1):49–53

    Article  PubMed  Google Scholar 

  21. Nadarajah R, Mahaluxmivala J, Amin A, Goodier DW (2005) Clavicular hook-plate: complications of retaining the implant. Injury 36(5):681–683

    Article  CAS  PubMed  Google Scholar 

  22. Choi S, Kim SR, Kang H, Kim D, Park YG (2015) Modified tension band fixation and coracoclavicular stabilisation for unstable distal clavicle fracture. Injury 46(2):259–264

    Article  PubMed  Google Scholar 

  23. Shin SJ, Roh KJ, Kim JO, Sohn HS (2009) Treatment of unstable distal clavicle fractures using two suture anchors and suture tension bands. Injury 40(12):1308–1312

    Article  PubMed  Google Scholar 

  24. Hohmann E, Hansen T, Tetsworth K (2012) Treatment of Neer type II fractures of the lateral clavicle using distal radius locking plates combined with TightRope augmentation of the coraco-clavicular ligaments. Arch Orthop Trauma Surg 132(10):1415–1421

    Article  PubMed  Google Scholar 

  25. Spiegl UJ, Smith SD, Euler SA, Dornan GJ, Millett PJ, Wijdicks CA (2014) Biomechanical consequences of coracoclavicular reconstruction techniques on clavicle strength. Am J Sports Med 42(7):1724–1730

    Article  PubMed  Google Scholar 

  26. Stucken C, Cohen SB (2015) Management of acromioclavicular joint injuries. Orthop Clin N Am 46(1):57–66

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Wichan Kanchanatawan.

Ethics declarations

Conflict of interest

All authors declare that they have no conflict of interests.

Informed consent

Informed consent was obtained from all individual participants included in the study. Approval for this study was given by the Committee on human related to research involving human subjects at Lerdsin General Hospital.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kanchanatawan, W., Wongthongsalee, P. Management of acute unstable distal clavicle fracture with a modified coracoclavicular stabilization technique using a bidirectional coracoclavicular loop system. Eur J Orthop Surg Traumatol 26, 139–143 (2016). https://doi.org/10.1007/s00590-015-1723-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00590-015-1723-1

Keywords

Navigation