Skip to main content
Log in

Implementation of locking compression plate together with intramedullary fibular graft in atrophic type humeral nonunions

  • Original Article
  • Published:
European Journal of Orthopaedic Surgery & Traumatology Aims and scope Submit manuscript

Abstract

Objective

This study aims to report the results of locking compression plate along with intramedullary fibular graft that was implemented in patients with the diagnosis of nonunion of humerus diaphysis.

Materials and methods

Five patients, operated between 2000 and 2009 for atrophic type nonunion of humeral diaphysis, were included in this study. Two patients were women (40%) and three were men (60%). The mean age was 49.2 years. Nonunion was found to be on the right humerus of 3 patients and on the left side of 2 patients. Causes of fractures were traffic accident in 2 cases, simple fall in 2 cases, and fall from height in 1 case. Mean duration after the elementary fracture was 70 months. Nonunion was diagnosed at 1/3 proximal humeral diaphysis in 2 patients, 1/3 distal humeral diaphysis in 2 patients, and 1/3 middle humeral diaphysis in one patient. Initially, conservative treatment was chosen for 3 cases and plate-screw osteosynthesis for 2 cases.

Results

Complete union was obtained in all cases radiologically. Mean union time was 20.1 weeks. With a mean of 1.78 cm, shortening was detected in comparative radiographies of both humeri. Mean range of motion at the elbow was 118° in flexion–extension arch of patients. The mean Constant-Murley score was 88 points. There was no complication regarding the operation and graft donor sites.

Conclusion

The management of atrophic type humeral nonunions is difficult. The method that we practice in such patients is a reliable treatment option with its stabile fixation and high union rates.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Volgas DA, Stannard JP, Alonso JE (2004) Nonunions of the humerus. Clin Orthop Relat Res 419:46–50

    Article  PubMed  Google Scholar 

  2. Ring D, Kloen P, Kadzielski J et al (2004) Locking compression plates for osteoporotic nonunions of the diaphyseal humerus. Clin Orthop Relat Res 425:50–54

    Article  PubMed  Google Scholar 

  3. Epps CH Jr, Grant RE (1991) Fractures of the shaft of the humerus. In: Rockwood CA Jr, Green DP, Bucholz RW (eds) Rockwood and Green’s fractures in adults, vol 1, 3rd edn. J. B. Lippincott, Philadelphia, pp 843–869

    Google Scholar 

  4. Micic I, Mitkovic M, Mladenovic D, Stanojlovic M, Jeon IH (2007) Treatment of the humeral shaft nonunion after surgical failure using the Selfdynamisable internal fixator. Arch Orthop Trauma Surg 127(8):713–718

    Article  PubMed  Google Scholar 

  5. Marinelli A, Antonioli D, Guerra E, Bettelli G, Zaccarelli L, Rotini R (2009) Humeral shaft aseptic nonunion: treatment with opposite cortical allograft struts. Chir Organi Mov 93(Suppl 1):21–28

    Google Scholar 

  6. Atalar AC, Kocaoglu M, Demirhan M, Bilsel K, Eralp L (2008) Comparison of three different treatment modalities in the management of humeral shaft nonunions (plates, unilateral, and circular external fixators). J Orthop Trauma 22(4):248–257

    Article  PubMed  Google Scholar 

  7. Constant CR, Murley AH (1987) A clinical method of functional assessment of the shoulder. Clin Orthop Relat Res 214:160–164

    PubMed  Google Scholar 

  8. Oztürk I, Ertürer E, Uzun M, Akman S, Seçkin F (2006) The effectiveness of functional bracing in the conservative treatment of humeral diaphyseal fractures. Acta Orthop Traumatol Turc 40(4):269–273

    PubMed  Google Scholar 

  9. Balfour GW, Mooney V, Ashby ME (1982) Diaphyseal fractures of the humerus treated with a ready-made fracture brace. J Bone Joint Surg (Am) 64(A):11–13

    CAS  Google Scholar 

  10. Pugh DM, McKee MD (2003) Advances in the management of humeral nonunion. J Am Acad Orthop Surg 11(1):48–59

    PubMed  Google Scholar 

  11. Vidyadhara S, Vamsi K, Rao SK, Gnanadoss JJ, Pandian S (2009) Use of intramedullary fibular strut graft: a novel adjunct to plating in the treatment of osteoporotic humeral shaft nonunion. Int Orthop 33(4):1009–1014

    Article  PubMed  CAS  Google Scholar 

  12. Hierholzer C, Sama D, Toro JB et al (2006) Plate fixation of ununited humeral shaft fractures: effect of type of bone graft on healing. J Bone Joint Surg (Am) 88(7):1442–1447

    Article  Google Scholar 

  13. Van Houwelingen AP, McKee MD (2005) Treatment of osteopenic humeral shaft nonunion with compression plating, humeral cortical allograft struts, and bone grafting. J Orthop Trauma 19(1):36–42

    Article  PubMed  Google Scholar 

  14. Borus TA, Yian EH, Karunakar MA (2005) A case series and review of salvage surgery for refractory humeral shaft nonunion following two or more prior surgical procedures. Iowa Orthop J. 25:194–199

    PubMed  Google Scholar 

  15. Rubel IF, Kloen P, Campbell D et al (2002) Open Reduction and internal fixation of humeral nonunions. J Bone Joint Surg (Am) 84(A):1315–1322

    Google Scholar 

  16. Nadkarni B, Srivastav S, Mittal V, Agarwal S (2008) Use of locking compression plates for long bone nonunions without removing existing intramedullary nail: review of literature and our experience. J Trauma 65(2):482–486

    Article  PubMed  Google Scholar 

  17. Martinez AA, Cuenca J, Herrera A (2004) Treatment of humeral shaft nonunions: nailing versus plating. Arch Orthop Trauma Surg 124(2):92–95

    Article  PubMed  Google Scholar 

  18. Wu CC, Shih CH (1992) Treatment for non-union of the shaft of the humerus: comparison of plates and Seidel interlocking nails. Can J Surg 35(6):661–665

    PubMed  CAS  Google Scholar 

  19. Lammens J, Baudin G, Driessen R et al (1998) Treatment of nonunion of the humerus using the Ilizarov external fixator. Clin Orthop Relat Res 353:223–230

    Article  PubMed  Google Scholar 

  20. Wright TW, Miller GJ, Vander Griend RA, Wheeler D, Dell PC (1993) Reconstruction of the humerus with an intramedullary fibular graft. A clinical and biomechanical study. J Bone Joint Surg (Br) 75(5):804–807

    CAS  Google Scholar 

Download references

Conflict of interest

No funds were received in support of this study. The author(s) of this manuscript has/have chosen not to furnish Ejost and its readers with information regarding any relationship that might exist between a commercial party and material contained in this manuscript that might represent a potential conflict of interest. No benefits in any form have been or will be received from a commercial party related directly or indirectly to the subject of this manuscript.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Sonmez Mehmet Mesut.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Erden, E.R., Arda, C., Mesut, S.M. et al. Implementation of locking compression plate together with intramedullary fibular graft in atrophic type humeral nonunions. Eur J Orthop Surg Traumatol 22, 661–665 (2012). https://doi.org/10.1007/s00590-011-0900-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00590-011-0900-0

Keywords

Navigation