Abstract
A new method and fluid filter with micro through capillary array for high-throughput micro fluidics were proposed and fabricated. The method, utilizing liquid surface tension and directing fluid flow in vertical direction, was achieved by using the fluid filter we originally proposed. The computational fluid dynamics analysis was conducted to examine the feasibility of vertical fluid flow operation using the fluid filter. And the results indicated that the vertical fluid flow operation is useful and the good properties of the fluid filter. Fabrication of fluid filter was successfully conducted by using deep X-ray lithography. And vertical fluid flow operation and its high throughput properties were successfully demonstrated.
Similar content being viewed by others
References
Ando A, Amano S, Hashimoto S, Kinoshita H, Miyamoto S, Mochizuki T, Niibe M, Shoji Y, Terasawa M, Watanabe T, Kumagai N (1998) J Synchrotron Rad 5:342
Emrich CA, Medintz IL, Tian H, Berti L, Mathies RA (2001) Proc μTAS2001, pp 13–15
Sato K, Yamanaka M, Tokeshi M, Morishima K, Kitamori T (2003) Proc. μTAS2003, pp 781–784
Utsumi Y, Kishimoto T, Mekaru H, Hattori T (2004a) Proc ICEE2004, pp 608–613
Utsumi Y, Kishimoto T, Mekaru H, Hara H (2004b) Proc IWMF2004, pp 275–280
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Ukita, Y., Asano, T. & Utsumi, Y. Fluid filter fabricated by deep X-ray lithography for micro fluidics. Microsyst Technol 13, 435–439 (2007). https://doi.org/10.1007/s00542-006-0218-8
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00542-006-0218-8