A new infrared tympanic thermometer

  • Original Articles
  • Published:
Journal of Anesthesia Aims and scope Submit manuscript

Abstract

We have evaluated a new infrared tympanic thermometer, IT-10, as an intraoperative temperature monitor in patients with or without open abdominal surgery. It determines temperature by measuring infrared radiation given off by a warm object. Temperatures measured with this device were closely correlated with those measured with rectal and bladder thermometries. We conclude that this new tympanic thermometer is safe, convenient, accurate, and easily usable in the clinical situation.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  1. Smith NT: Subcutaneous, muscle, and body temperatures in anesthetized man. J Appl Physiol 17:306–310, 1962

    CAS  PubMed  Google Scholar 

  2. Holdcroft A: Body temperature controll in anesthesia, surgery, intensive care. London, Bailliere Tindall, 1988, pp. 4–40

    Google Scholar 

  3. Dickey WT, Ahlgren EW, Stephan CR: Body temperature monitoring via the tympanic membrane. Surgery 67:981–984, 1970

    CAS  PubMed  Google Scholar 

  4. Shinozaki T, Deane R, Perkins FM: Infrared tympanic thermometer: Evaluation of a new clinical thermometer. Crit Care Med 16:148–150, 1988

    Article  CAS  PubMed  Google Scholar 

  5. Johnson KJ, Bhatia RNP, Bell EF: Infrared thermometry of newborn infants. Pediatrics 87:34–38, 1991

    CAS  PubMed  Google Scholar 

  6. Imrie MM, Hall GM: Body temperature and anaesthesia. Br J Anaesth 64:346–354, 1990

    Article  CAS  PubMed  Google Scholar 

  7. Vaughan MS: Shivering in the recovery room. Curr Rev R R Nurse 6:2–7, 1984

    Google Scholar 

  8. Sessler DI: Temperature regulation and anesthesia. ASA Annual Refresher Course Lectures 1991, 243

  9. Sessler DI, Olofsson CI, Rubinstein EH, et al: The thermoregulatory threshold in humans during halothane anesthesia. Anesthesiology 68:836–842, 1988

    Article  CAS  PubMed  Google Scholar 

  10. Sessler DI, Moayeri A: Skin-surface warming: heat flux and central temperature. Anesthesiology 73:218–224, 1990

    Article  CAS  PubMed  Google Scholar 

  11. Hall GM: Body temperature and anaesthesia. Br J Anaesth 50:39–44, 1978

    Article  CAS  PubMed  Google Scholar 

  12. Cork RC, Vaughan RW, Humphrey LS: Precision and accuracy of intraoperative temperature monitoring. Anesth Analg 62:211–214, 1983

    Article  CAS  PubMed  Google Scholar 

  13. Benzinger TH, Tayler GW: Cranial measurements of internal temperature in man. Temperature: its measurement and control in science and industry. New York, Reinhold, 1963, pp. 111–120

    Google Scholar 

  14. Hensel H: Neural processes in thermoregulation. Physiol Rev 53:948–1017, 1973

    Google Scholar 

  15. Benzinger TH: Clinical temperature: new physiological basis. JAMA 209:1200–1206, 1969

    Article  CAS  PubMed  Google Scholar 

  16. Benzinger M: Tympanic thermometry in surgery and anesthesia. J AMA 209:1207–1211, 1969

    CAS  Google Scholar 

  17. Wallace CT, Marks WE, Adkins WY, et al: Perforation of the tympanic membrane, a complication of tympanic thermometry during anesthesia. Anesthesiology 41:290–291, 1974

    Article  CAS  PubMed  Google Scholar 

  18. Kenney RD, Fortenberry JD, Surratt SS, et al: Evaluation of an infrared tympanic membrane thermometer in pediatric patients. Pediatrics 85:854–858, 1990

    CAS  PubMed  Google Scholar 

  19. Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307–310, 1986

    CAS  PubMed  Google Scholar 

  20. LaMantia KP, O’Connor T, Barash PG: Comparing methods of measurement: An alternative approach. Anesthesiology 72:781–783, 1990

    Article  CAS  PubMed  Google Scholar 

  21. Wong DH, Tremper KK, Stemmer EA, et al: Noninvasive cardiac output: Simultaneous comparison of two different methods with thermodilution. Anesthesiology 72:784–792, 1990

    Article  CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

About this article

Cite this article

Matsukawa, T., Kashimoto, S., Miyaji, T. et al. A new infrared tympanic thermometer. J Anesth 7, 33–39 (1993). https://doi.org/10.1007/s0054030070033

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s0054030070033

Key words

Navigation