Abstract
We have evaluated a new infrared tympanic thermometer, IT-10, as an intraoperative temperature monitor in patients with or without open abdominal surgery. It determines temperature by measuring infrared radiation given off by a warm object. Temperatures measured with this device were closely correlated with those measured with rectal and bladder thermometries. We conclude that this new tympanic thermometer is safe, convenient, accurate, and easily usable in the clinical situation.
Similar content being viewed by others
References
Smith NT: Subcutaneous, muscle, and body temperatures in anesthetized man. J Appl Physiol 17:306–310, 1962
Holdcroft A: Body temperature controll in anesthesia, surgery, intensive care. London, Bailliere Tindall, 1988, pp. 4–40
Dickey WT, Ahlgren EW, Stephan CR: Body temperature monitoring via the tympanic membrane. Surgery 67:981–984, 1970
Shinozaki T, Deane R, Perkins FM: Infrared tympanic thermometer: Evaluation of a new clinical thermometer. Crit Care Med 16:148–150, 1988
Johnson KJ, Bhatia RNP, Bell EF: Infrared thermometry of newborn infants. Pediatrics 87:34–38, 1991
Imrie MM, Hall GM: Body temperature and anaesthesia. Br J Anaesth 64:346–354, 1990
Vaughan MS: Shivering in the recovery room. Curr Rev R R Nurse 6:2–7, 1984
Sessler DI: Temperature regulation and anesthesia. ASA Annual Refresher Course Lectures 1991, 243
Sessler DI, Olofsson CI, Rubinstein EH, et al: The thermoregulatory threshold in humans during halothane anesthesia. Anesthesiology 68:836–842, 1988
Sessler DI, Moayeri A: Skin-surface warming: heat flux and central temperature. Anesthesiology 73:218–224, 1990
Hall GM: Body temperature and anaesthesia. Br J Anaesth 50:39–44, 1978
Cork RC, Vaughan RW, Humphrey LS: Precision and accuracy of intraoperative temperature monitoring. Anesth Analg 62:211–214, 1983
Benzinger TH, Tayler GW: Cranial measurements of internal temperature in man. Temperature: its measurement and control in science and industry. New York, Reinhold, 1963, pp. 111–120
Hensel H: Neural processes in thermoregulation. Physiol Rev 53:948–1017, 1973
Benzinger TH: Clinical temperature: new physiological basis. JAMA 209:1200–1206, 1969
Benzinger M: Tympanic thermometry in surgery and anesthesia. J AMA 209:1207–1211, 1969
Wallace CT, Marks WE, Adkins WY, et al: Perforation of the tympanic membrane, a complication of tympanic thermometry during anesthesia. Anesthesiology 41:290–291, 1974
Kenney RD, Fortenberry JD, Surratt SS, et al: Evaluation of an infrared tympanic membrane thermometer in pediatric patients. Pediatrics 85:854–858, 1990
Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307–310, 1986
LaMantia KP, O’Connor T, Barash PG: Comparing methods of measurement: An alternative approach. Anesthesiology 72:781–783, 1990
Wong DH, Tremper KK, Stemmer EA, et al: Noninvasive cardiac output: Simultaneous comparison of two different methods with thermodilution. Anesthesiology 72:784–792, 1990
Author information
Authors and Affiliations
About this article
Cite this article
Matsukawa, T., Kashimoto, S., Miyaji, T. et al. A new infrared tympanic thermometer. J Anesth 7, 33–39 (1993). https://doi.org/10.1007/s0054030070033
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/s0054030070033