Abstract
The ICT sector is responsible for around 2 % of the global energy consumption, with data centres taking large fraction of this consumption. In many current data centres the actual IT equipment uses only half of the total energy while the remaining part is required for cooling and air movement. This results in poor cooling efficiency and energy efficiency, leading to significant CO2 emissions. EU project CoolEmAll investigates in a holistic approach how cooling, heat transfer, IT infrastructure, and application-workloads influence overall cooling and energy efficiency of data centres. In March 2013, CoolEmAll developed the 1st prototype of a Simulation, Visualisation and Decision support toolkit (SVD Toolkit), enabling assessment and user-driven optimisation of cooling efficiency in data centres by means of coupled workload- and thermal-airflow simulation. In this paper we describe architecture of the SVD Toolkit and present results enabling assessment and optimisation of cooling efficiency in data centres.
Similar content being viewed by others
References
Bak S, Krystek M Kurowski K, Oleksiak A, Piatek W, Weglarz J (2011) GSSIM—a tool for distributed computing experiments. Sci Program 19(4):231–251
COllaborative VIsualisation and Simulation Environment, http://www.hlrs.de/organization/av/vis/covise/
CoolEmAll project-web-site, http://www.coolemall.eu
Hintemann R, Pfah S (2008) Energy efficiency in the data center—a guide to the planning, modernization and operation of data centers. In: BITKOM, vol 3
Hoyer M, vor dem Berge M, Volk E, Gallizo G, Buchholz J, Fornós R, Sisó L, Piatek W (2012) D3.2 First definition of the modular compute box with integrated cooling—CoolEmAll Deliverable, http://coolemall.eu
Kipp A, Woessner U (2011) CoolEmAll—platform for optimizing the design, operation and cooling of modular configurable IT infrastructures. inSiDE 9(2)
Koomey J (2008) Worldwide electricity used in data centers. Environ Res Lett 3:034008
OpenFOAM project web-site, http://www.openfoam.org
Prieto JL, Gallizo G, Oleksiak A, Volk E (2012) D6.1 Validation scenarios, methodology and metrics—CoolEmAll deliverable, http://coolemall.eu
Rathgeb D, Volk E (2013) D2.4 First release of the simulation and visualisation toolkit—CoolEmAll deliverable, http://coolemall.eu
Sisó L, Fornós RB, Napolitano A, Salomon J, Da Costa G, Volk E, Donoghue A (2012) D5.1 White paper on energy- and heat-aware metrics for computing modules—CoolEmAll deliverable, http://coolemall.eu
Study conducted by Borderstep Institute and Fraunhofer IZM (Materialbestand der Rechenzentren in Deutschland, Eine Bestandsaufnahme zur Ermittlung von Ressourcen- und Energieeinsatz, UBA) (2010)
vor dem Berge M, Da Costa G, Kopecki A, Oleksiak A, Pierson J-M, Piontek T, Volk E, Wesner S (2012) Modeling and simulation of data center energy-efficiency in CoolEmAll. In: Proceedings of the 1st international workshop on energy-efficient data centres
vor dem Berge M, Da Costa G, Jarus M, Oleksiak A, Piatek W, Volk E (2013) Modeling data center building blocks for energy-efficiency and thermal solutions. In: Proceedings of the international workshop on energy-efficient data centres, co-located with E-energy (E2DC)
vor dem Berge M, Krupop S, Klisik (Christmann) T, Buchholz J (2013) D3.3 First release of the concept for the flexible rack-level ComputeBox with integrated cooling—CoolEmAll deliverable, http://coolemall.eu
vor dem Berge M, Sisó L, Thiebolt F, Buchholz J (2013) D3.4 First release of the concept for the modular ComputeBox with integrated cooling—CoolEmAll deliverable, http://coolemall.eu
Woessner U, Volk E, Gallizo G, vor dem Berge M, Da Costa G, Domagalski P, Piatek W, Pierson J-M (2012) D2.2 Design of the CoolEmAll simulation and visualisation environment—CoolEmAll deliverable, http://coolemall.eu
Acknowledgements
The results presented in this paper are partially funded by the European Commission under contract 288701 through the project CoolEmAll.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Volk, E., Rathgeb, D. & Oleksiak, A. CoolEmAll—optimising cooling efficiency in data centres. Comput Sci Res Dev 29, 253–261 (2014). https://doi.org/10.1007/s00450-013-0246-4
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00450-013-0246-4