Skip to main content
Log in

Biological monitoring in workers in a nitrobenzene reduction plant: haemoglobin versus serum albumin adducts

  • ORIGINAL ARTICLE
  • Published:
International Archives of Occupational and Environmental Health Aims and scope Submit manuscript

Abstract

The high priority of monitoring workers exposed to nitrobenzene is a consequence of clear findings of experimental carcinogenicity of nitrobenzene and the associated evaluations by the International Agency for Research on Cancer. Eighty male employees of a nitrobenzene reduction plant, with potential skin contact with nitrobenzene and aniline, participated in a current medical surveillance programme. Blood samples were routinely taken and analysed for aniline, 4-aminodiphenyl (4-ADP) and benzidine adducts of haemoglobin (Hb) and human serum albumin (HSA). Also, levels of methaemoglobin (Met-Hb) and of carbon monoxide haemoglobin (CO-Hb) were monitored. Effects of smoking were straightforward. Using the rank sum test of Wilcoxon, we found that very clear-cut and statistically significant smoking effects (about 3-fold increases) were apparent on CO-Hb (P=0.00085) and on the Hb adduct of 4-ADP (P=0.0006). The mean aniline-Hb adduct level in smokers was 1.5 times higher than in non-smokers; the significance (P=0.05375) was close to the 5% level. The strongest correlation was evident between the Hb and HSA adducts of aniline (rs=0.846). Less pronounced correlations (but with P values < 0.02) appeared between aniline-Hb and 4-ADP-Hb adducts (rs=0.388), between 4-ADP and 4-ADP-HSA adducts (rs=0.373), and between 4-ADP-Hb and aniline-HSA adducts (rs=0.275). In view of the proposal for additional use of the aniline-HSA adduct for biological monitoring, particularly in cases of acute overexposures or poisonings, the strong correlation of the Hb and HSA conjugates is noteworthy; the ratio aniline-HSA:aniline-Hb was 1:42 for the entire cohort.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 2 June 2000 / Accepted: 21 April 2001

Rights and permissions

Reprints and permissions

About this article

Cite this article

Thier, R., Lewalter, J., Selinski, S. et al. Biological monitoring in workers in a nitrobenzene reduction plant: haemoglobin versus serum albumin adducts. Int Arch Occup Environ Health 74, 483–488 (2001). https://doi.org/10.1007/s004200100250

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s004200100250

Navigation