Purpose

The purpose of this study is to investigate optic nerve head using spectral domain optical coherence tomography (SD-OCT) in children with large cupping.

Methods

111 eyes (4–10 years) were divided into three groups according to the cup to disc ratio: group 1, ≤0.3; group 2, 0.4–0.6; and group 3, ≥0.7. The rim area, disc area, average cup to disc ratio, vertical cup to disc ratio, and cup volume were investigated using SD-OCT (Cirrus HD-OCT, Carl Zeiss, Jena, Germany), and the axial length and anterior chamber depth (ACD) were measured by IOL master (IOL master 500, Carl Zeiss, Jena, Germany). Next, we compared ocular biometry and SD-OCT between the three groups.

Results

The mean age of group1 was 6.48 ± 1.42 years, 7.00 ± 1.75 years in group 2, and 6.63 ± 1.82 years in group 3 (p = 0.370). A significant difference was seen in the spherical equivalent between the groups (p = 0.001). Group 2 had the most myopic refractive errors. As the cup to disc ratio increases, disc area, average cup to disc ratio, vertical cup to disc ratio, and cup volume increase significantly. When the results of ocular biometry and SD-OCT are adjusted for axial length, only disc area showed a significant correlation with cup to disc ratio (ACD: p = 0.473, rim area: p = 0.639, disc area: p = 0.005, and cup volume: p = 0.325).

Conclusion

Axial length is the key factor determining disc size, which in turn is important for determining cup to disc ratio. Normal children with large cupping should be examined for axial length, myopic refractive errors, and disc size.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Mrugacz M, Bakunowicz-Lazarczyk A (2005) Optical coherence tomography measurement of the retinal nerve fiber layer in normal and juvenile glaucomatous eyes. Ophthalmologica 219:80–85

    Article  PubMed  Google Scholar 

  2. El-Dairi M, Holgado S, Asrani S, Freedman SF (2011) Optical coherence tomography (OCT) measurements in black and white children with large cup-to-disc ratios. Exp Eye Res 93:299–307

    Article  PubMed  CAS  Google Scholar 

  3. Healey PR, Mitchell P, Smith W, Wang JJ (1997) Relationship between cup-disc ratio and optic disc diameter: the Blue Mountains Eye Study. Aust N Z J Ophthalmol 25(Suppl 1):S99–S101

    Article  PubMed  Google Scholar 

  4. Healey PR, Mitchell P, Smith W, Wang JJ (1997) The influence of age and intraocular pressure on the optic cup in a normal population. J Glaucoma 6:274–278

    Article  PubMed  CAS  Google Scholar 

  5. Rao HL, Kumar AU, Babu JG, Kumar A, Senthil S, Garudadri CS (2011) Predictors of normal optic nerve head, retinal nerve fiber layer, and macular parameters measured by spectral domain optical coherence tomography. Invest Ophthalmol Vis Sci 52:1103–1110

    Article  PubMed  Google Scholar 

  6. Huynh SC, Wang XY, Rochtchina E, Crowston JG, Mitchell P (2006) Distribution of optic disc parameters measured by OCT: findings from a population-based study of 6-year-old Australian children. Invest Ophthalmol Vis Sci 47:3276–3285

    Article  PubMed  Google Scholar 

  7. Savini G, Barboni P, Carbonelli M, Sbreglia A, Deluigi G, Parisi V (2012) Comparison of optic nerve head parameter measurements obtained by time-domain and spectral-domain optical coherence tomography. J Glaucoma. doi:10.1097/IJG.0b013e31824c9423

    Google Scholar 

  8. Varma R, Tielsch JM, Quigley HA, Hilton SC, Katz J, Spaeth GL, Sommer A (1994) Race-, age-, gender-, and refractive error-related differences in the normal optic disc. Arch Ophthalmol 112:1068–76

    Google Scholar 

  9. Wu RY, Wong TY, Zheng YF, Cheung CY, Perera SA, Saw SM, Aung T (2011) Influence of refractive error on optic disc topographic parameters: the singapore malay eye study. Am J Ophthalmol 152:81–86

    Article  PubMed  Google Scholar 

  10. Wang Y, Xu L, Zhang L, Yang H, Ma Y, Jonas JB (2006) Optic disc size in a population based study in northern China: the Beijing Eye Study. Br J Ophthalmol 90:353–356

    Article  PubMed  CAS  Google Scholar 

  11. Wissa AR, Wahba SS, Roshdy MM (2012) Agreement and relationship between ultrasonic and partial coherence interferometry measurements of axial length and anterior chamber depth. Clin Ophthalmol 6:193–198

    PubMed  Google Scholar 

  12. Turk A, Ceylan OM, Arici C, Keskin S, Erdurman C, Durukan AH, Mutlu FM, Altinsoy HI (2012) Evaluation of the nerve fiber layer and macula in the eyes of healthy children using spectral-domain optical coherence tomography. Am J Ophthalmol 153:552–559

    Article  PubMed  Google Scholar 

  13. Savini G, Barboni P, Parisi V, Carbonelli M (2012) The influence of axial length on retinal nerve fibre layer thickness and optic-disc size measurements by spectral-domain OCT. Br J Ophthalmol 96:57–61

    Article  PubMed  Google Scholar 

  14. Leung CK, Cheng AC, Chong KK, Leung KS, Mohamed S, Lau CS, Cheung CY, Chu GC, Lai RY, Pang CC, Lam DS (2007) Optic disc measurements in myopia with optical coherence tomography and confocal scanning laser ophthalmoscopy. Invest Ophthalmol Vis Sci 48:3178–3183

    Article  PubMed  Google Scholar 

  15. Cheung CY, Chen D, Wong TY, Tham YC, Wu R, Zheng Y, Cheng CY, Saw SM, Baskaran M, Leung CK, Aung T (2011) Determinants of quantitative optic nerve measurements using spectral domain optical coherence tomography in a population-based sample of non-glaucomatous subjects. Invest Ophthalmol Vis Sci 52(13):9629–9635

    Article  PubMed  Google Scholar 

  16. Tsai DC, Huang N, Hwu JJ, Jueng RN, Chou P (2012) Estimating retinal nerve fiber layer thickness in normal schoolchildren with spectral-domain optical coherence tomography. Jpn J Ophthalmol 56(4):362–370

    Article  PubMed  Google Scholar 

  17. Moghimi S, Hosseini H, Riddle J, Lee GY, Bitrian E, Giaconi J, Caprioli J, Nouri-Mahdavi K (2012) Measurement of optic disc size and rim area with spectral-domain OCT and scanning laser ophthalmoscopy. Invest Ophthalmol Vis Sci 53(8):4519–4530

    Article  PubMed  Google Scholar 

  18. Mansoori T, Viswanath K, Balakrishna N (2011) Optic disc topography in normal Indian eyes using spectral domain optical coherence tomography. Indian J Ophthalmol 59:23–27

    Article  PubMed  Google Scholar 

Download references

Financial interest

None of the authors have any proprietary/financial interest to disclose.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Ungsoo Samuel Kim.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Jung, J.J., Baek, SH. & Kim, U.S. Biometry and spectral domain optical coherence tomography parameters in children with large cupping. Graefes Arch Clin Exp Ophthalmol 251, 2213–2217 (2013). https://doi.org/10.1007/s00417-013-2340-5

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00417-013-2340-5

Keywords

Navigation