Abstract
In modern medico-legal literature, only a small number of publications deal with fatal injuries from black powder guns. Most of them focus on the morphological features such as intense soot soiling, blast tattooing and burn effects in close-range shots or describe the wound ballistics of spherical lead bullets. Another kind of “unusual” and potentially lethal weapons are handguns destined for firing only blank cartridges such as starter and alarm pistols. The dangerousness of these guns is restricted to very close and contact range shots and results from the gas jet produced by the deflagration of the propellant. The present paper reports on a suicide committed with a muzzle-loading percussion pistol cal. 45. An unusually large stellate entrance wound was located in the precordial region, accompanied by an imprint mark from the ramrod and a faint greenish discoloration (apparently due to the formation of sulfhemoglobin). Autopsy revealed an oversized powder cavity, multiple fractures of the anterior thoracic wall as well as ruptures of the heart, the aorta, the left hepatic lobe and the diaphragm. In total, the zone of mechanical destruction had a diameter of approx. 15 cm. As there was no exit wound and no bullet lodged in the body, the injury was caused exclusively by the inrushing combustion gases of the propellant (black powder) comparable with the gas jet of a blank cartridge gun. In contact shots to ballistic gelatine using the suicide’s pistol loaded with black powder but no projectile, the formation of a nearly spherical cavity could be demonstrated by means of a high-speed camera. The extent of the temporary cavity after firing with 5 g of black powder roughly corresponded to the zone of destruction found in the suicide’s body.
Similar content being viewed by others
References
Pollak S, Rothschild MA (2004) Gunshot injuries as a topic of medicolegal research in the German-speaking countries from the beginning of the 20th century up to the present time. Forensic Sci Int 144:201–210
Große Perdekamp M, Braunwarth R, Kromeier J, Nadjem H, Pollak S, Thierauf A (2013) Muzzle-loading weapons discharging spherical lead bullets: two case studies and experimental simulation using a skin-soap composite model. Int J Legal Med 127:791–797
Kneubuehl BP, Coupland RM, Rothschild MA, Thali MJ (2011) Wound ballistics. Basics and applications. Springer, Berlin, p 37, 104–105, 136–154, 208–212
Missliwetz J, Wieser I (1990) Medical and technical aspects of the effect of weapons III. Black powder muzzle-loading guns. Beitr Gerichtl Med 48:685–696
Jussila J (2004) Preparing ballistic gelatine—review and proposal for a standard method. Forensic Sci Int 141:91–98
Große Perdekamp M, Vennemann B, Kneubuehl BP, Uhl M, Treier M, Braunwarth R, Pollak S (2008) Effect of shortening the barrel in contact shots from rifles and shotguns. Int J Legal Med 122:81–85
Dodd MD (2006) Terminal ballistics. A text and atlas of gunshot wounds. CRC Press, Boca Raton, pp 77–82
De Haan JD (1983) Homicide with a black powder handgun. J Forensic Sci 28:468–481
Karger B, Teige K (1998) Fatalities from black powder percussion handguns. Forensic Sci Int 98:143–149
Lieske K, Janssen W, Kulle K-J (1991) Intensive gunshot residues at the exit wound: an examination using a head model. Int J Legal Med 104:235–238
Pavelites JJ, Kintzele D, Fotia PK, Prahlow JA (2010) Death by black powder revolver: a case report. Forensic Sci Med Pathol 6:298–303
Hartwig S, Tsokos M, Byard R (2009) Black powder handgun deaths remain an uncommon event. Am J Forensic Med Pathol 30:350–353
Hejna P, Šafr M, Zátopková L, Straka L (2012) Complex suicide with black powder muzzle loading derringer. Forensic Sci Med Pathol 8:296–300
Vila RI, Martin JV, Wetli CV, Freeman R (1990) Accidental death from a black-powder rifle breech plug. Am J Forensic Med Pathol 11:241–243
DiMaio VJM (1999) Gunshot wounds. Practical aspects of firearms, ballistics, and forensic techniques, 2nd edn. CRC Press, Boca Raton, pp 29–31
Labowitz DI, Menzie RC, Scroggie RJ (1981) Characteristics and wounding effects of a black powder handgun. J Forensic Sci 26:288–301
Rothschild MA (1999) Freiverkäufliche Schreckschusswaffen. Medizinische, rechtliche und kriminaltechnische Bewertung. Schmidt-Römhild, Lübeck, pp 59–95
Rothschild MA, Kneubuehl BP (1996) Physikalische Grundlagen zur Messung von Gasdruck und Energiestrom bei Schreckschusswaffen. Arch Kriminol 198:151–159
Jacob B, Huckenbeck W, Daldrup T, Haarhoff K, Bonte W (1990) Suicides by starter’s pistols and air guns. Am J Forensic Med Pathol 11:285–290
Maxeiner H, Schneider V (1989) Injuries and fatalities caused by gas-/warning weapons. Arch Kriminol 184:84–92
Rothschild MA, Karger B, Strauch H, Joachim H (1998) Fatal wounds to the thorax caused by gunshots from blank cartridges. Int J Legal Med 111:78–81
Rothschild MA, Maxeiner H (1994) Unusual findings in a case of suicide with a gas weapon. Int J Legal Med 106:274–276
Rothschild MA, Maxeiner H, Schneider V (1994) Cases of death caused by gas or warning firearms. Med Law 13:511–518
Rothschild MA, Vendura K (1999) Fatal neck injuries caused by blank cartridges. Forensic Sci Int 101:151–159
Tausch D, Wagner HJ (1978) Über zwei tödliche Verletzungen mit Gas- und Schreckschusswaffen. Kriminalistik 32:451–452
Tausch D, Sattler W, Wehrfritz K, Wehrfritz G, Wagner HJ (1974) Tödliche Schussverletzungen mit “unbedenklichen”Gas- und Schreckschussfaustfeuerwaffen. Z Rechtsmed 75:71–77
Voisard MX, Kneubuehl BP (2010) Danger assessment of a spring-gun device (muzzle loader) loaded only with black powder. Am J Forensic Med Pathol 31:95–97
Zink P (1976) Tödliche Verletzungen durch Schreckschusswaffen. Z Rechtsmed 78:91–96
Große Perdekamp M, Kneubuehl BP, Ishikawa T, Nadjem H, Kromeier J, Pollak S, Thierauf A (2010) Secondary skull fractures in head wounds inflicted by captive bolt guns: autopsy findings and experimental simulation. Int J Legal Med 124:605–612
Große Perdekamp M, Pollak S, Thierauf A (2011) Composite models simulating soft tissue targets in experimental ballistics. Fol Soc Med Leg Slov 2:58–62
Schyma C (2012) Wounding capacity of muzzle-gas pressure. Int J Legal Med 126:371–376
Schyma C, Schyma P (1999) The wounding capacity of blank cartridges using a gelatine model. Rechtsmedizin 9:210–214
Schyma P, Schyma C (2000) Dangers of blank firearms—risk of injury and expert assessment. Versicherungsmedizin 52:141–146
Große Perdekamp M, Arnold M, Merkel J, Mierdel K, Braunwarth R, Kneubuehl BP, Pollak S, Thierauf A (2011) GSR deposition along the bullet path in contact shots to composite models. Int J Legal Med 125:67–73
Park CM, Nagel RL, Blumberg WE, Peisach J, Magliozzo RS (1986) Sulfhemoglobin. Properties of partially sulfurated tetramers. J Biol Chem 261:8805–8810
Pollak S, Saukko P (2013) Gunshot wounds. In: Siegel JA, Saukko PJ (eds) Encyclopedia of forensic sciences, vol 3, 2nd edn. Academic, London, pp 70–82
Karger B, Kersting C, Brinkmann B (1997) Prior exposure of the entrance wound region from clothing is uncommon in firearm suicides. Int J Legal Med 110:79–81
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Große Perdekamp, M., Glardon, M., Kneubuehl, B.P. et al. Fatal contact shot to the chest caused by the gas jet from a muzzle-loading pistol discharging only black powder and no bullet: case study and experimental simulation of the wounding effect. Int J Legal Med 129, 125–131 (2015). https://doi.org/10.1007/s00414-014-1064-3
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00414-014-1064-3