Skip to main content
Log in

Fatal contact shot to the chest caused by the gas jet from a muzzle-loading pistol discharging only black powder and no bullet: case study and experimental simulation of the wounding effect

  • Original Article
  • Published:
International Journal of Legal Medicine Aims and scope Submit manuscript

Abstract

In modern medico-legal literature, only a small number of publications deal with fatal injuries from black powder guns. Most of them focus on the morphological features such as intense soot soiling, blast tattooing and burn effects in close-range shots or describe the wound ballistics of spherical lead bullets. Another kind of “unusual” and potentially lethal weapons are handguns destined for firing only blank cartridges such as starter and alarm pistols. The dangerousness of these guns is restricted to very close and contact range shots and results from the gas jet produced by the deflagration of the propellant. The present paper reports on a suicide committed with a muzzle-loading percussion pistol cal. 45. An unusually large stellate entrance wound was located in the precordial region, accompanied by an imprint mark from the ramrod and a faint greenish discoloration (apparently due to the formation of sulfhemoglobin). Autopsy revealed an oversized powder cavity, multiple fractures of the anterior thoracic wall as well as ruptures of the heart, the aorta, the left hepatic lobe and the diaphragm. In total, the zone of mechanical destruction had a diameter of approx. 15 cm. As there was no exit wound and no bullet lodged in the body, the injury was caused exclusively by the inrushing combustion gases of the propellant (black powder) comparable with the gas jet of a blank cartridge gun. In contact shots to ballistic gelatine using the suicide’s pistol loaded with black powder but no projectile, the formation of a nearly spherical cavity could be demonstrated by means of a high-speed camera. The extent of the temporary cavity after firing with 5 g of black powder roughly corresponded to the zone of destruction found in the suicide’s body.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6

Similar content being viewed by others

References

  1. Pollak S, Rothschild MA (2004) Gunshot injuries as a topic of medicolegal research in the German-speaking countries from the beginning of the 20th century up to the present time. Forensic Sci Int 144:201–210

    Article  CAS  Google Scholar 

  2. Große Perdekamp M, Braunwarth R, Kromeier J, Nadjem H, Pollak S, Thierauf A (2013) Muzzle-loading weapons discharging spherical lead bullets: two case studies and experimental simulation using a skin-soap composite model. Int J Legal Med 127:791–797

    Article  Google Scholar 

  3. Kneubuehl BP, Coupland RM, Rothschild MA, Thali MJ (2011) Wound ballistics. Basics and applications. Springer, Berlin, p 37, 104–105, 136–154, 208–212

    Google Scholar 

  4. Missliwetz J, Wieser I (1990) Medical and technical aspects of the effect of weapons III. Black powder muzzle-loading guns. Beitr Gerichtl Med 48:685–696

    PubMed  CAS  Google Scholar 

  5. Jussila J (2004) Preparing ballistic gelatine—review and proposal for a standard method. Forensic Sci Int 141:91–98

    Article  CAS  Google Scholar 

  6. Große Perdekamp M, Vennemann B, Kneubuehl BP, Uhl M, Treier M, Braunwarth R, Pollak S (2008) Effect of shortening the barrel in contact shots from rifles and shotguns. Int J Legal Med 122:81–85

    Article  Google Scholar 

  7. Dodd MD (2006) Terminal ballistics. A text and atlas of gunshot wounds. CRC Press, Boca Raton, pp 77–82

    Google Scholar 

  8. De Haan JD (1983) Homicide with a black powder handgun. J Forensic Sci 28:468–481

    Google Scholar 

  9. Karger B, Teige K (1998) Fatalities from black powder percussion handguns. Forensic Sci Int 98:143–149

    Article  CAS  Google Scholar 

  10. Lieske K, Janssen W, Kulle K-J (1991) Intensive gunshot residues at the exit wound: an examination using a head model. Int J Legal Med 104:235–238

    Article  CAS  Google Scholar 

  11. Pavelites JJ, Kintzele D, Fotia PK, Prahlow JA (2010) Death by black powder revolver: a case report. Forensic Sci Med Pathol 6:298–303

    Article  Google Scholar 

  12. Hartwig S, Tsokos M, Byard R (2009) Black powder handgun deaths remain an uncommon event. Am J Forensic Med Pathol 30:350–353

    Article  Google Scholar 

  13. Hejna P, Šafr M, Zátopková L, Straka L (2012) Complex suicide with black powder muzzle loading derringer. Forensic Sci Med Pathol 8:296–300

    Article  Google Scholar 

  14. Vila RI, Martin JV, Wetli CV, Freeman R (1990) Accidental death from a black-powder rifle breech plug. Am J Forensic Med Pathol 11:241–243

    Article  CAS  Google Scholar 

  15. DiMaio VJM (1999) Gunshot wounds. Practical aspects of firearms, ballistics, and forensic techniques, 2nd edn. CRC Press, Boca Raton, pp 29–31

    Google Scholar 

  16. Labowitz DI, Menzie RC, Scroggie RJ (1981) Characteristics and wounding effects of a black powder handgun. J Forensic Sci 26:288–301

    Article  CAS  Google Scholar 

  17. Rothschild MA (1999) Freiverkäufliche Schreckschusswaffen. Medizinische, rechtliche und kriminaltechnische Bewertung. Schmidt-Römhild, Lübeck, pp 59–95

    Google Scholar 

  18. Rothschild MA, Kneubuehl BP (1996) Physikalische Grundlagen zur Messung von Gasdruck und Energiestrom bei Schreckschusswaffen. Arch Kriminol 198:151–159

    Google Scholar 

  19. Jacob B, Huckenbeck W, Daldrup T, Haarhoff K, Bonte W (1990) Suicides by starter’s pistols and air guns. Am J Forensic Med Pathol 11:285–290

    Article  CAS  Google Scholar 

  20. Maxeiner H, Schneider V (1989) Injuries and fatalities caused by gas-/warning weapons. Arch Kriminol 184:84–92

    PubMed  CAS  Google Scholar 

  21. Rothschild MA, Karger B, Strauch H, Joachim H (1998) Fatal wounds to the thorax caused by gunshots from blank cartridges. Int J Legal Med 111:78–81

    Article  CAS  Google Scholar 

  22. Rothschild MA, Maxeiner H (1994) Unusual findings in a case of suicide with a gas weapon. Int J Legal Med 106:274–276

    Article  CAS  Google Scholar 

  23. Rothschild MA, Maxeiner H, Schneider V (1994) Cases of death caused by gas or warning firearms. Med Law 13:511–518

    PubMed  CAS  Google Scholar 

  24. Rothschild MA, Vendura K (1999) Fatal neck injuries caused by blank cartridges. Forensic Sci Int 101:151–159

    Article  CAS  Google Scholar 

  25. Tausch D, Wagner HJ (1978) Über zwei tödliche Verletzungen mit Gas- und Schreckschusswaffen. Kriminalistik 32:451–452

    Google Scholar 

  26. Tausch D, Sattler W, Wehrfritz K, Wehrfritz G, Wagner HJ (1974) Tödliche Schussverletzungen mit “unbedenklichen”Gas- und Schreckschussfaustfeuerwaffen. Z Rechtsmed 75:71–77

    Article  CAS  Google Scholar 

  27. Voisard MX, Kneubuehl BP (2010) Danger assessment of a spring-gun device (muzzle loader) loaded only with black powder. Am J Forensic Med Pathol 31:95–97

    Article  Google Scholar 

  28. Zink P (1976) Tödliche Verletzungen durch Schreckschusswaffen. Z Rechtsmed 78:91–96

    Article  CAS  Google Scholar 

  29. Große Perdekamp M, Kneubuehl BP, Ishikawa T, Nadjem H, Kromeier J, Pollak S, Thierauf A (2010) Secondary skull fractures in head wounds inflicted by captive bolt guns: autopsy findings and experimental simulation. Int J Legal Med 124:605–612

    Article  Google Scholar 

  30. Große Perdekamp M, Pollak S, Thierauf A (2011) Composite models simulating soft tissue targets in experimental ballistics. Fol Soc Med Leg Slov 2:58–62

    Google Scholar 

  31. Schyma C (2012) Wounding capacity of muzzle-gas pressure. Int J Legal Med 126:371–376

    Article  Google Scholar 

  32. Schyma C, Schyma P (1999) The wounding capacity of blank cartridges using a gelatine model. Rechtsmedizin 9:210–214

    Article  Google Scholar 

  33. Schyma P, Schyma C (2000) Dangers of blank firearms—risk of injury and expert assessment. Versicherungsmedizin 52:141–146

    PubMed  CAS  Google Scholar 

  34. Große Perdekamp M, Arnold M, Merkel J, Mierdel K, Braunwarth R, Kneubuehl BP, Pollak S, Thierauf A (2011) GSR deposition along the bullet path in contact shots to composite models. Int J Legal Med 125:67–73

    Article  Google Scholar 

  35. Park CM, Nagel RL, Blumberg WE, Peisach J, Magliozzo RS (1986) Sulfhemoglobin. Properties of partially sulfurated tetramers. J Biol Chem 261:8805–8810

    PubMed  CAS  Google Scholar 

  36. Pollak S, Saukko P (2013) Gunshot wounds. In: Siegel JA, Saukko PJ (eds) Encyclopedia of forensic sciences, vol 3, 2nd edn. Academic, London, pp 70–82

    Chapter  Google Scholar 

  37. Karger B, Kersting C, Brinkmann B (1997) Prior exposure of the entrance wound region from clothing is uncommon in firearm suicides. Int J Legal Med 110:79–81

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Markus Große Perdekamp.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Große Perdekamp, M., Glardon, M., Kneubuehl, B.P. et al. Fatal contact shot to the chest caused by the gas jet from a muzzle-loading pistol discharging only black powder and no bullet: case study and experimental simulation of the wounding effect. Int J Legal Med 129, 125–131 (2015). https://doi.org/10.1007/s00414-014-1064-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00414-014-1064-3

Keywords

Navigation