Abstract
Estimation of the firing range is often critical for reconstructing gunshot fatalities, where the main measurable evidence is the gunshot residue (GSR). In the present study intermediate-range gunshot wounds have been analysed by means of a micro-computed tomography (micro-CT) coupled to an image analysis software in order to quantify the powder particles and to determine the firing distance. A total of 50 shootings were performed on skin sections obtained from human legs surgically amputated for medical reasons. For each tested distance (5, 15, 23, 30 and 40 cm), firing was carried out perpendicularly at the samples using a 7.65-mm pistol loaded with jacketed bullets. Uninjured skin sections were used as controls. By increasing the firing distance, micro-CT analysis demonstrated a clear decreasing trend in the mean GSR percentage, particularly for shots fired from more than 15 cm. For distances under 23 cm, the powder particles were concentrated on the epidermis and dermis around the hole, and inside the cavity; while, at greater distances, they were deposited only on the skin surface. Statistical analysis showed a nonlinear relationship between the amount of GSR deposits and the firing range, well explained by a Gaussian-like function. The proposed method allowed a good discrimination for all the tested distances, proving to be an objective, rapid and inexpensive tool for estimating the firing range in intermediate-range gunshot wounds.
Similar content being viewed by others
References
Di Maio VJM (1999) Gunshot wounds. Practical aspects of firearms, ballistics, and forensic techniques. CRC Press, Boca Raton
Sellier K (1991) Shot range determination. Forensic science program vol. 6. Springer, Berlin
Nag NK, Sinha P (1992) A note on assessability of firing distance from gunshot residues. Forensic Sci Int 56:1–17
Matty W (1987) Primer composition and gunshot residue. Assoc Firearms Tool Mark Exam J 19:8–13
Wallace JS (1990) Chemical aspects of firearms ammunition. Assoc Firearms Tool Mark Exam J 22:364–389
Brown H, Cauchi DM, Holden JL, Wrobel H, Cordner S (1999) Image analysis of gunshot residue on entry wounds. I—the technique and preliminary study. Forensic Sci Int 100:163–177
Karger B, Puskas Z, Ruwald B, Teige K, Schuirer G (1998) Morphological findings in the brain after experimental gunshots using radiology, pathology and histology. Int J Leg Med 111:314–319
Adeyi O, Duval JV, Dupre ME, Andrew TA (2005) Role of chemical tests and scene investigation in determination of range of fire. Am J Forensic Med Pathol 26:166–169
Tschirhart DL, Noguchi TT, Klatt EC (1991) A simple histochemical technique for the identification of gunshot residue. J Forensic Sci 36:543–547
Brown H, Cauchi DM, Holden JL, Allen FC, Cordner S, Thatcher P (1999) Image analysis of gunshot residue on entry wounds. II—a statistical estimation of firing range. Forensic Sci Int 100:179–186
Marty W, Sigrist T, Wyler D (2002) Determination of firing distance using the rhodizonate staining technique. Int J Leg Med 116:1–4
Neri M, Di TE, Riezzo I, Fineschi V (2007) The determination of firing distance applying a microscopic quantitative method and confocal laser scanning microscopi for detection of gunshot residue particles. Int J Leg Med 121:287–292
Krishnan SS (1974) Firing distance determination by atomic absorption spectroscopy. J Forensic Sci 19:351–386
Seamster A, Mead T, Gislason J, Jackson K, Ruddy F, Pate BD (1976) Studies of the spatial distribution of firearms discharge residues. J Forensic Sci 21:868–882
Capannesi G, Ciavola C, Sedda AF (1993) Determination of firing distance and firing angle by neutron activation analysis in a case involving gunshot wounds. Forensic Sci Int 61:75–84
De Gaetano D, Siegel JA (1990) Survey of gunshot residue analysis in forensic science laboratories. J Forensic Sci 5:1087–1095
Ueyama M, Taylor RL, Noguchi TT (1980) SEMS/EDS analysis of muzzle deposits at different target distances. Scann Electr Microsc 1:367–374
Rutty GN, Boyce P, Robinson CE, Jeffery AJ, Morgan B (2008) The role of computed tomography in terminal ballistic analysis. Int J Leg Med 122:1–5
Stein KM, Bahner ML, Merkel J, Ain S (2000) Detection of gunshot residues in routine CTs. Int J Leg Med 114:15–18
Cnudde V, Masschaele B, De Cock H, Olstad VL, Jacobs P (2008) Virtual histology by means high resolution X-ray CT. J Microsc 232:476–485
Rainio J, Lalu K, Ranta H, Penttila A (2003) Morphology of experimental assault rifle skin wounds. Int J Leg Med 117:19–26
Große Perdekamp M, Vennemann B, Mattern D, Serr A, Pollak S (2005) Tissue defect at the gunshot entrance wound: what happens to the skin? Int J Leg Med 119:217–222
Bartell TH, Mustoe TA (1989) Animal models of human tissue expansion. Plast Reconstr Surg 83:681–686
Schantz B (1979) Aspects on the choice of experimental animals when reproducing missile trauma. Acta Chir Scand Suppl 489:121–129
Karger B, Billeb E, Koops E, Brinkmann B (2002) Autopsy features relevant for discrimination between suicidal and homicidal gunshot injuries. Int J Leg Med 116:273–278
Kijewski H, Bock G (1983) Veränderungen der Sb- und Pb-Konzentration im Abstreifring bei Schüssen mit Langwaffen aus Entfernungen bis 400 m. Beitr Gerichtl Med 41:383–389
Berryman HE, Kutyla AK, Davis RJ 2nd (2010) Detection of gunshot primer residue on bone in an experimental setting—an unexpected finding. J Forensic Sci 55:488–491
Viel G, Cecchetto G, Fabbri LD, Furlan C, Ferrara SD, Montisci M (2009) Forensic application of ESEM and XRF-EDS techniques to a fatal case of sodium phosphate enema intoxication. Int J Leg Med 123:345–350
Brozek-Mucha Z, Jankowicz A (2001) Evaluation of the possibility of differentiation between various types of ammunition by means of GSR examination with SEM-EDX method. Forensic Sci Int 123:39–47
Acknowledgements
The authors are grateful to Mr. Ennio Orpini of the Ballistic Laboratory of the ‘Historical Orpini's Armoury’ for his help in conducting the shooting trials.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Cecchetto, G., Giraudo, C., Amagliani, A. et al. Estimation of the firing distance through micro-CT analysis of gunshot wounds. Int J Legal Med 125, 245–251 (2011). https://doi.org/10.1007/s00414-010-0533-6
Received:
Accepted:
Published:
Issue Date: