Skip to main content
Log in

Improvement of LIEF by wavelength-resolved acquisition of multiple images using a single CCD detector – Simultaneous 2D measurement of air/fuel ratio, temperature distribution of the liquid phase and qualitative distribution of the liquid phase with the Multi-2D technique

  • Published:
Applied Physics B Aims and scope Submit manuscript

Abstract

The exciplex tracer system fluorobenzene (FB) and diethyl-methyl-amine (DEMA) in a solution of n-hexane and methyl-tert.-butylether (MTBE) was used to investigate the mixture formation in a fired direct injection spark ignition engine. The scope of this paper is the recently developed Multi-2D technique, which allows for the simultaneous measurement of the local air/fuel ratio (λ-distribution of the vapor phase), the qualitative distribution of the liquid phase, the temperature distribution of the liquid phase, and the detection of Mie scattering in this application. Basically, the Multi-2D technique consists of a new optical setup, which images the same field of view four times onto one camera, thus combining spatial and spectral resolution based on interference filters. The liquid temperature is derived via “two-line” thermometry. Using the liquid phase temperature the crosstalk from the liquid into the spectral detection range of the vapor phase is corrected. Quantitative results of the crosstalk-corrected vapor phase signals are achieved by an in-situ calibration.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. J.F. Le Coz, J. Cherel, S. Le Mirronet, Oil Gas Sci. Technol. 58, 63 (2003)

    Article  Google Scholar 

  2. A.C. Eckbreth, Laser Diagnostics for Combustion and Species (Abacus Press, Cambridge, 1988)

    Google Scholar 

  3. P.G. Felton, F.V. Bracco, M.E.A. Bardsley, SAE 930870 (1993)

  4. A.P. Fröba, F. Rabenstein, K.-U. Münch, A. Leipertz, Combust. Flame 112, 199 (1998)

    Article  Google Scholar 

  5. S. Frigo, Evaluation of fluorescing tracers for hexane and isooctane, Report (1981), M.A.E. Dept., Princeton Uni. (1993)

  6. J.B. Ghandi, P.G. Felton, B.F. Gajdeczko, F.V. Bracco, Investigation of the fuel distribution in a two-stroke engine with an air-assisted injector, SAE 940394 (1994)

  7. N. Graf, PhD Thesis, Ruprecht-Karls-Universität Heidelberg (2003)

  8. G. Grünefeld, M. Schütte, P. Andresen, Appl. Phys. B 70, 309 (2000)

    Article  ADS  Google Scholar 

  9. A.M. Halpern, S.L. Frye, J. Phys. Chem. 92, 6620 (1988)

    Article  Google Scholar 

  10. T. Kadota, K. Miyoshi, M. Tsue, JSME Int. J. B 36, 371 (1993)

    Google Scholar 

  11. W. Koban, PhD Thesis, Ruperto-Carola University of Heidelberg (2005)

  12. C.F. Lee, B.F. Gajdezko, Quantitative exciplex measurements of the vapor concentration in air-assisted sprays, ILASS Americas 96. Extended abstract in Proc. 9th Annu. Conf. on Liquid Atomization and Spray Systems (1996) pp. 297–301

  13. L.A. Melton, Appl. Opt. 22, 2224 (1983)

    Article  ADS  Google Scholar 

  14. L.A. Melton, Appl. Spectrosc. 47, 782 (1993)

    Article  ADS  Google Scholar 

  15. L.A. Melton, J.F. Verdieck, Combust. Sci. Technol. 42, 217 (1985)

    Article  Google Scholar 

  16. A.M. Murray, L.A. Melton, Appl. Opt. 24, 2783 (1985)

    Article  ADS  Google Scholar 

  17. C. Parigger, D.H. Plemmons, R.J. Litchford, S.M. Jeng, Opt. Lett. 23, 76 (1998)

    Article  ADS  Google Scholar 

  18. J. Reboux, D. Puechberty, F. Dionnet, A new approach of PLIF applied to fuel/air ratio measurement in the compression stroke of an optical si engine, SAE technical paper series 941988 (1994)

  19. C. Schulz, V. Sick, Prog. Energ. Combust. Sci. 31, 75 (2005)

    Article  Google Scholar 

  20. R. Shimizu, S. Matumoto, S. Furuno, M. Murayama, S. Kojima, Measurement of air-fuel mixture distribution in a gasoline engine using lief technique, SAE 922356 (1992)

  21. H. Voges, T. Berg, D. Weide, T. Müller, V. Beushausen, S. Krüger, G. Grünefeld, Spray imaging systems for quantitative spray analysis, (ILASS-ASIA, 2000)

  22. P. Wieske, G. Grünefeld, Messung der Kraftstoffverteilung in Flüssig- und Dampfphase mittels laser induzierter exciplex Fluoreszenz (LIEF), In BMBF Abschlussworkshop Turbulenz in der Energietechnik (2005)

  23. H. Zhao, N. Ladommatos, Prog. Energ. Combust. Sci. 24, 297 (1998)

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to P. Wieske.

Additional information

PACS

42.62.Fi; 44.35.+c

Rights and permissions

Reprints and permissions

About this article

Cite this article

Wieske, P., Wissel, S., Grünefeld, G. et al. Improvement of LIEF by wavelength-resolved acquisition of multiple images using a single CCD detector – Simultaneous 2D measurement of air/fuel ratio, temperature distribution of the liquid phase and qualitative distribution of the liquid phase with the Multi-2D technique. Appl. Phys. B 83, 323–329 (2006). https://doi.org/10.1007/s00340-006-2173-6

Download citation

  • Received:

  • Revised:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00340-006-2173-6

Keywords

Navigation