Abstract
Objectives
To retrospectively compare the accuracy of fine-needle aspiration (FNA) and core-needle biopsy (CNB) for the diagnosis of thyroid malignancy
Methods
We evaluated the results of FNA and CNB in 555 consecutive thyroid nodules with final diagnoses (malignancy 318, benign 237). All patients underwent FNA and CNB simultaneously for each nodule. We assessed the sensitivity, specificity and accuracy of FNA, CNB and FNA/CNB for the diagnosis of thyroid malignancy.
Results
The sensitivity of FNA, CNB and FNA/CNB for thyroid malignancy was 68.6%, 86.8% and 90.6%, specificity 100%, 99.2% and 99.2%, and accuracy 82.0%, 92.1% and 94.2%, respectively. The sensitivity and accuracy of CNB or FNA/CNB for thyroid malignancy were significantly higher than those of FNA (P < 0.001). Compared with CNB alone, FNA/CNB was more accurate for thyroid malignancy only in small nodules less than 1 cm (P < 0.001).
Conclusions
Our clinical cohort data demonstrated that CNB was more accurate for the diagnosis of thyroid malignancy than FNA, and FNA/CNB was more accurate than CNB alone in small thyroid nodules. CNB will play a complementary role in optimal surgical decision-making and the management of thyroid nodules.
Key Points
• CNB was more accurate for the diagnosis of malignancy than FNA.
• Combined FNA/CNB was more accurate than CNB alone in small thyroid nodules.
• CNB should play at least a complementary role in managing thyroid nodules.
Similar content being viewed by others
References
Goudy SL, Flynn MB (2005) Diagnostic accuracy of palpation-guided and image-guided fine-needle aspiration biopsy of the thyroid. Ear Nose Throat J 84:371–374
Cesur M, Corapcioglu D, Bulut S et al (2006) Comparison of palpation-guided fine-needle aspiration biopsy to ultrasound-guided fine-needle aspiration biopsy in the evaluation of thyroid nodules. Thyroid 16:555–561
Mehrotra P, Hubbard JG, Johnson SJ, Richardson DL, Bliss R, Lennard TW (2005) Ultrasound scan-guided core sampling for diagnosis versus freehand FNAC of the thyroid gland. Surgeon 3:1–5
Ghofrani M, Beckman D, Rimm DL (2006) The value of onsite adequacy assessment of thyroid fine-needle aspirations is a function of operator experience. Cancer 108:110–113
Izquierdo R, Arekat MR, Knudson PE et al (2006) Comparison of palpation-guided versus ultrasound-guided fine-needle aspiration biopsies of thyroid nodules in an outpatient endocrinology practice. Endocr Pract 12:609–614
Danese D, Sciacchitano S, Farsetti A, Andreoli M, Pontecorvi A (1998) Diagnostic accuracy of conventional versus sonography-guided fine-needle aspiration biopsy of thyroid nodules. Thyroid 8:15–21
Hatada T, Okada K, Ishii H, Ichii S, Utsunomiya J (1998) Evaluation of ultrasound-guided fine-needle aspiration biopsy for thyroid nodules. Am J Surg 175:133–136
Cai XJ, Valiyaparambath N, Nixon P, Waghorn A, Giles T, Helliwell T (2006) Ultrasound-guided fine needle aspiration cytology in the diagnosis and management of thyroid nodules. Cytopathology 17:251–256
Yassa L, Cibas ES, Benson CB et al (2007) Long-term assessment of a multidisciplinary approach to thyroid nodule diagnostic evaluation. Cancer Cytopathol 111:508–516
Yang J, Schnadig V, Logrono R, Wasserman PG (2007) Fine-needle aspiration of thyroid nodules: a study of 4703 patients with histologic and clinical correlations. Cancer 111:306–315
Nayar R, Ivanovic M (2009) The indeterminate thyroid fine-needle aspiration: experience from an academic center using terminology similar to that proposed in the 2007 National Cancer Institute Thyroid Fine Needle Aspiration State of the Science Conference. Cancer Cytopathol 117:195–202
Gharib H, Papini E, Paschke R et al (2010) AACE/AME/ETA Task Force on Thyroid Nodules. American Association of Clinical Endocrinologists, Associazione Medici Endocrinologi, and European Thyroid Association medical guidelines for clinical practice for the diagnosis and management of thyroid nodules. Endocr Pract 16:1–43
Baloch ZW, Cibas ES, Clark DP et al (2008) The National Cancer Institute thyroid fine needle aspiration state of the science conference: a summation. Cytojournal 5:6
Elsheikh TM, Singh HK, Silverman JF (2007) Fine-needle aspiration cytology versus core needle biopsy in the evaluation of thyroid and salivary gland lesions. Pathol Case Rev 12:3–9
Park KT, Ahn SH, Mo JH et al (2011) Role of core needle biopsy and ultrasonographic finding in management of indeterminate thyroid nodules. Head Neck 33:160–165
Quinn SF, Nelson HA, Demlow TA (1994) Thyroid biopsies: fine-needle aspiration biopsy versus spring-activated core biopsy needle in 102 patients. J Vasc Interv Radiol 5:619–623
Liu Q, Castelli M, Gattuso P, Prinz RA (1995) Simultaneous fine-needle aspiration and core-needle biopsy of thyroid nodules. Am Surg 61:628–632
Taki S, Kakuda K, Kakuma K et al (1997) Thyroid nodules: evaluation with US-guided core biopsy with an automated biopsy gun. Radiology 202:874–877
Pisani T, Bononi M, Nagar C, Angelini M, Bezzi M, Vecchione A (2000) Fine needle aspiration and core needle biopsy techniques in the diagnosis of nodular thyroid pathologies. Anticancer Res 20:3843–3847
Karstrup S, Balslev E, Juul N, Eskildsen PC, Baumbach L (2001) US-guided fine needle aspiration versus coarse needle biopsy of thyroid nodules. Eur J Ultrasound 13:1–5
Screaton NJ, Berman LH, Grant JW (2003) US-guided core-needle biopsy of the thyroid gland. Radiology 226:827–832
Harvey JN, Parker D, De P, Shrimali RK, Otter M (2005) Sonographically guided core biopsy in the assessment of thyroid nodules. J Clin Ultrasound 33:57–62
Renshaw AA, Pinnar N (2007) Comparison of thyroid fine-needle aspiration and core needle biopsy. Am J Clin Pathol 128:370–374
Moon WJ, Baek JH, Jung SL et al (2011) Korean Society of Thyroid Radiology (KSThR); Korean Society of Radiology. Ultrasonography and the ultrasound-based management of thyroid nodules: consensus statement and recommendations. Korean J Radiol 12:1–14
Ki KH, Park YJ, Koong S et al (2010) Revised Korean Thyroid Association management guidelines for patients with thyroid nodules and thyroid cancer. J Korean Thyroid Assoc 3:65–96
Cibas ES, Ali SZ (2009) The Bethesda system for reporting thyroid cytopathology. Thyroid 19:1159–1165
Cibas ES, Ali SZ (2010) The Bethesda system for reporting thyroid cytopathology, 1st edn. Springer, New York, pp 1–89
Raab SS, Vrbin CM, Grzybicki DM et al (2006) Errors in thyroid gland fine-needle aspiration. Am J Clin Pathol 125:873–882
Redman R, Zalaznick H, Mazzaferri EL, Massoll NA (2006) The impact of assessing specimen adequacy and number of needle passes for fine-needle aspiration biopsy of thyroid nodules. Thyroid 16:55–60
O'Malley ME, Weir MM, Hahn PF, Misdraji J, Wood BJ, Mueller PR (2002) US-guided fine-needle aspiration biopsy of thyroid nodules: adequacy of cytologic material and procedure time with and without immediate cytologic analysis. Radiology 222:383–387
Wang C, Vickery AL Jr, Maloof F (1976) Needle biopsy of the thyroid. Surg Gynecol Obstet 143:365–368
Boey J, Hsu C, Wong J, Ong GB (1982) Fine-needle aspiration versus drill-needle biopsy of thyroid nodules: a controlled clinical trial. Surgery 91:611–615
Lo Gerfo P, Colacchio T, Caushaj F, Weber C, Feind C (1982) Comparison of fine-needle and coarse-needle biopsies in evaluating thyroid nodules. Surgery 92:835–838
Miller JM, Kini SR, Hamburger JI (1985) The diagnosis of malignant follicular neoplasms of the thyroid by needle biopsy. Cancer 55:2812–2817
Jung SL, Jung CK, Kim SH et al (2010) Histopathologic findings related to the indeterminate or inadequate results of fine-needle aspiration biopsy and correlation with ultrasonographic findings in papillary thyroid carcinomas. Korean J Radiol 11:141–148
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Sung, J.Y., Na, D.G., Kim, K.S. et al. Diagnostic accuracy of fine-needle aspiration versus core-needle biopsy for the diagnosis of thyroid malignancy in a clinical cohort. Eur Radiol 22, 1564–1572 (2012). https://doi.org/10.1007/s00330-012-2405-6
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00330-012-2405-6