Skip to main content
Log in

Patients with no functional improvement after total knee arthroplasty show different kinematics

  • Original Paper
  • Published:
International Orthopaedics Aims and scope Submit manuscript

Abstract

Purpose

As many as 20 % of all patients following total knee arthroplasty are not satisfied with the result. Rotational alignment is one factor thought to affect clinical outcome. The purpose of this study was to assess relationships between prosthesis rotational alignment, function score and knee kinematics after TKA.

Methods

In 80 patients a cemented, unconstrained, cruciate-retaining TKA with a rotating platform was implanted. Rotational alignment was measured using CT-scans. Kinematics was assessed using fluoroscopy images.

Results

Seventy-three patients were available for follow-up after two years. Nine patients had more than 10° rotational mismatch between the femoral and tibial component in the postoperative CT scans. These patients showed significantly worse results in the function score. While the normal patients with less than 10° rotational mismatch improved from a mean pre-operative 55 points to a mean 71 points at follow-up, the group with more than 10° mismatch deteriorated from a mean 60 points pre-operatively to a mean 57 points at follow-up. The pattern of motion during passive flexion from approximately 0° to 120° was quite different. While external rotation steadily increased with knee flexion in the normal group, there was internal rotation between 30° and 80° of flexion in the group with more than 10° rotational mismatch.

Conclusion

Rotational mismatch between femoral and tibial components exceeding 10° resulted in different kinematics after TKA. It might contribute to worse clinical results observed in those patients and should therefore be avoided.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Dunbar MJ (2001) Subjective outcomes after knee arthroplasty. Acta Orthop Scand Suppl 72:1–63

    Article  PubMed  CAS  Google Scholar 

  2. Nilsdotter AK, Toksvig-Larsen S, Roos EM (2009) Knee arthroplasty: are patients' expectations fulfilled? A prospective study of pain and function in 102 patients with 5-year follow-up. Acta Orthop 80:55–61

    Article  PubMed  Google Scholar 

  3. Nunez M, Lozano L, Nunez E, Segur JM, Sastre S, Macule F, Ortega R, Suso S (2009) Total knee replacement and health-related quality of life: factors influencing long-term outcomes. Arthritis Rheum 61:1062–1069

    Article  PubMed  Google Scholar 

  4. Andriacchi TP, Galante JO, Fermier RW (1982) The influence of total knee-replacement design on walking and stair-climbing. J Bone Joint Surg Am 64:1328–1335

    PubMed  CAS  Google Scholar 

  5. Kim YH, Yoon SH, Kim JS (2009) Early outcome of TKA with a medial pivot fixed-bearing prosthesis is worse than with a PFC mobile-bearing prosthesis. Clin Orthop Relat Res 467:493–503

    Article  PubMed  Google Scholar 

  6. Pritchett JW (2004) Patient preferences in knee prostheses. J Bone Joint Surg Br 86:979–982

    Article  PubMed  CAS  Google Scholar 

  7. Andersson GB, Andriacchi TP, Galante JO (1981) Correlations between changes in gait and in clinical status after knee arthroplasty. Acta Orthop Scand 52:569–573

    Article  PubMed  CAS  Google Scholar 

  8. Banks SA, Markovich GD, Hodge WA (1997) In vivo kinematics of cruciate-retaining and -substituting knee arthroplasties. J Arthroplasty 12:297–304

    Article  PubMed  CAS  Google Scholar 

  9. Hatfield GL, Hubley-Kozey CL, Astephen Wilson JL, Dunbar MJ (2011) The effect of total knee arthroplasty on knee joint kinematics and kinetics during gait. J Arthroplasty 26:309–318

    Article  PubMed  Google Scholar 

  10. Kitagawa A, Tsumura N, Chin T, Gamada K, Banks SA, Kurosaka M (2010) In vivo comparison of knee kinematics before and after high-flexion posterior cruciate-retaining total knee arthroplasty. J Arthroplasty 25:964–969

    Article  PubMed  Google Scholar 

  11. Markovich GD, Banks SA, Hodge WA (1998) Comparison of active and passive knee replacement kinematics. OrthopTrans 21:810–811

    Google Scholar 

  12. Barrack RL, Schrader T, Bertot AJ, Wolfe MW, Myers L (2001) Component rotation and anterior knee pain after total knee arthroplasty. Clin Orthop Relat Res 392:46–55

    Google Scholar 

  13. Berger RA, Crossett LS, Jacobs JJ, Rubash HE (1998) Malrotation causing patellofemoral complications after total knee arthroplasty. Clin Orthop Relat Res 356:144–153

    Google Scholar 

  14. DesJardins JD, Banks SA, Benson LC, Pace T, LaBerge M (2007) A direct comparison of patient and force-controlled simulator total knee replacement kinematics. J Biomech 40:3458–3466

    Article  PubMed  Google Scholar 

  15. Rhoads DD, Noble PC, Reuben JD, Tullos HS (1993) The effect of femoral component position on the kinematics of total knee arthroplasty. Clin Orthop Relat Res 286:122–129

    Google Scholar 

  16. Lützner J, Krummenauer F, Wolf C, Günther KP, Kirschner S (2008) Computer-assisted and conventional total knee replacement: a comparative, prospective, randomised study with radiological and CT evaluation. J Bone Joint Surg Br 90:1039–1044

    Article  PubMed  Google Scholar 

  17. Banks SA, Hodge WA (1996) Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy. IEEE Trans Biomed Eng 43:638–649

    Article  PubMed  CAS  Google Scholar 

  18. Banks SA, Hodge WA (2004) 2003 Hap Paul Award Paper of the International Society for Technology in Arthroplasty. Design and activity dependence of kinematics in fixed and mobile-bearing knee arthroplasties. J Arthroplasty 19:809–816

    Article  PubMed  Google Scholar 

  19. Banks SA, Hodge WA (2004) Implant design affects knee arthroplasty kinematics during stair-stepping. Clin Orthop Relat Res 426:187–193

    Google Scholar 

  20. Fantozzi S, Leardini A, Banks SA, Marcacci M, Giannini S, Catani F (2004) Dynamic in-vivo tibio-femoral and bearing motions in mobile bearing knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 12:144–151

    Article  PubMed  CAS  Google Scholar 

  21. Incavo SJ, Mullins ER, Coughlin KM, Banks S, Banks A, Beynnon BD (2004) Tibiofemoral kinematic analysis of kneeling after total knee arthroplasty. J Arthroplasty 19:906–910

    Article  PubMed  Google Scholar 

  22. Insall JN, Dorr LD, Scott RD, Scott WN (1989) Rationale of the Knee Society clinical rating system. Clin Orthop Relat Res 248:13–14

    PubMed  Google Scholar 

  23. Oppe M, Rabin R, de Charro F (2011) EQ-5D user guide. www.euroqol.org. Accessed 21 May 2012

  24. Seon JK, Park JK, Jeong MS, Jung WB, Park KS, Yoon TR, Song EK (2011) Correlation between preoperative and postoperative knee kinematics in total knee arthroplasty using cruciate retaining designs. Int Orthop 35:515–520

    Article  PubMed  Google Scholar 

  25. Kainz H, Reng W, Augat P, Wurm S (2012) Influence of total knee arthroplasty on patellar kinematics and contact characteristics. Int Orthop 36:73–78

    Article  PubMed  Google Scholar 

  26. Berend ME, Ritter MA, Meding JB, Faris PM, Keating EM, Redelman R, Faris GW, Davis KE (2004) Tibial component failure mechanisms in total knee arthroplasty. Clin Orthop Relat Res 428:26–34

    Google Scholar 

  27. Hofmann S, Romero J, Roth-Schiffl E, Albrecht T (2003) Rotational malalignment of the components may cause chronic pain or early failure in total knee arthroplasty. Orthopade 32:469–476

    PubMed  CAS  Google Scholar 

  28. Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73:709–714

    PubMed  CAS  Google Scholar 

  29. Lotke PA, Ecker ML (1977) Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg Am 59:77–79

    PubMed  CAS  Google Scholar 

  30. Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop Relat Res 299:153–156

    Google Scholar 

  31. Romero J, Stahelin T, Binkert C, Pfirrmann C, Hodler J, Kessler O (2007) The clinical consequences of flexion gap asymmetry in total knee arthroplasty. J Arthroplasty 22:235–240

    Article  PubMed  Google Scholar 

  32. Bedard M, Vince KG, Redfern J, Collen SR (2011) Internal rotation of the tibial component is frequent in stiff total knee arthroplasty. Clin Orthop Relat Res 469:2346–2355

    Article  PubMed  Google Scholar 

  33. Nicoll D, Rowley DI (2010) Internal rotational error of the tibial component is a major cause of pain after total knee replacement. J Bone Joint Surg Br 92:1238–1244

    Article  PubMed  CAS  Google Scholar 

  34. Akagi M, Mori S, Nishimura S, Nishimura A, Asano T, Hamanishi C (2005) Variability of extraarticular tibial rotation references for total knee arthroplasty. Clin Orthop Relat Res 436:172–176

    Google Scholar 

  35. Eckhoff DG, Metzger RG, Vandewalle MV (1995) Malrotation associated with implant alignment technique in total knee arthroplasty. Clin Orthop Relat Res 321:28–31

    Google Scholar 

  36. Huddleston JI, Scott RD, Wimberley DW (2005) Determination of neutral tibial rotational alignment in rotating platform TKA. Clin Orthop Relat Res 440:101–106

    Article  PubMed  Google Scholar 

  37. Uehara K, Kadoya Y, Kobayashi A, Ohashi H, Yamano Y (2002) Bone anatomy and rotational alignment in total knee arthroplasty. Clin Orthop 402:196–201

    Google Scholar 

  38. Wasielewski RC, Komistek RD, Zingde SM, Sheridan KC, Mahfouz MR (2008) Lack of axial rotation in mobile-bearing knee designs. Clin Orthop Relat Res 466:2662–2668

    Article  PubMed  Google Scholar 

  39. Lützner J, Krummenauer F, Günther KP, Kirschner S (2010) Rotational alignment of the tibial component in total knee arthroplasty is better at the medial third of tibial tuberosity than at the medial border. BMC Musculoskelet Disord 11:57

    Article  PubMed  Google Scholar 

Download references

Conflict of interest

The institution of one or more of the authors (JL, SK, MKH) has received funding from Stryker Orthopaedics.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jörg Lützner.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lützner, J., Kirschner, S., Günther, KP. et al. Patients with no functional improvement after total knee arthroplasty show different kinematics. International Orthopaedics (SICOT) 36, 1841–1847 (2012). https://doi.org/10.1007/s00264-012-1584-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00264-012-1584-8

Keywords

Navigation