Abstract
Here, we describe a goniometer holder to mount standard 96-well crystallization plates directly onto the goniometer head of an oscillation camera. This attachment was designed to check crystallization conditions straight from the crystallization plates under X-rays, and was proven to be useful for checking small crystals and solutions that destabilize monoolein-based lipidic cubic phase (LCP) crystallization experiments. A quick procedure for setting up LCP assays employing commercially available instruments is also reported.
Similar content being viewed by others
References
Ai X, Caffrey M (2000) Biophys J 79:394–405
Caffrey M (2000) Curr Opin Struct Biol 10:486–497
Caffrey M (2003) J Struct Biol 142:108–132
Cheng A, Hummel B, Qiu H, Caffrey M (1998) Chem Phys Lipids 95:11–21
Cherezov V, Fersi H, Caffrey M (2001) Biophys J 81:225–242
Cherezov V, Peddi A, Muthusubramaniuam L, Zheng YF, Caffrey M (2004) Acta Crystallogr D Biol Crystallogr 60:1795–1807
Cherezov V, Clogston J, Papiz MZ, Caffrey M (2006) J Mol Biol 357:1605–1618
Cribier S, Gulik A, Fellmann P, Vargas R, Devaux PF, Luzzati V (1993) J Mol Biol 229:517–525
Iwata S (2002) Methods and results in crystallization of membrane proteins. International University Line, La Jolla
Koynova R, Tenchov B (2001) Curr Opin Colloid Interface Sci 6:277–286
Landau E, Rosenbusch JP (1996) Proc Natl Acad Sci USA 93:14532–14535
Nollert P, Landau EM (1998) Biochem Soc Trans 26:709–713
Raman P, Cherezov V, Caffrey M (2006) Cell Mol Life Sci 63:36–51
Rummel J, Hardmeyer A, Widmer C, Chiu ML, Nollert P, Locher KP, Pedruzzi I, Landau EM, Rosenbuch JP (1998) J Struct Biol 121:82–91
Acknowledgments
The authors are grateful to Dr. Gonzalez-Ros and Dr. Fernandez Carvajal from the Instituto de Biología Molecular y Celular, Universidad Miguel Hernández, Elche, for providing KcsA protein samples. J.A. and A.C-B.’s work was supported by Novia Salcedo Foundation grants. A.M.’s work was supported by a Ministerio de Educación y Ciencia grant. D.M.A.G.’s work was partially supported by Bizkaia Xede association. A plate holder is available upon request (20 available). Please contact Dr. Diego M. A. Guérin at diego.guerin@ehu.es.
Author information
Authors and Affiliations
Corresponding author
Additional information
Both J. Agirre and A. Mechaly have contributed equally to this work.
Electronic supplementary material
Below is the link to the electronic supplementary material.
Rights and permissions
About this article
Cite this article
Agirre, J., Mechaly, A., Cabo-Bilbao, A. et al. A plate holder for non-destructive testing of mesophase crystallization assays. Eur Biophys J 37, 871–877 (2008). https://doi.org/10.1007/s00249-008-0296-x
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00249-008-0296-x