Abstract
When microdialysis (MD) membrane exceeds molecular weight cut-off (MWCO) of 100 kDa, the fluid mechanics are in the ultrafiltration regime. Consequently, fluidic mass transport of macromolecules in the perfusate over the membrane may reduce the biological relevance of the sampling and cause an inflammatory response in the test subject. Therefore, a method to investigate the molecular transport of high MWCO MD is presented. An in vitro test chamber was fabricated to facilitate the fluorescent imaging of the MD sampling process, using fluoresceinylisothiocyanate (FITC) dextran and fluorescence microscopy. Qualitative studies on dextran behavior inside and outside the membrane were performed. Semiquantitative results showed clear dextran leakage from both 40 and 250 kDa dextran when 100 kDa MWCO membranes were used. Dextran 40 kDa leaked out with an order of magnitude higher concentration and the leakage pattern resembled more of a convective flow pattern compared with dextran 250 kDa, where the leakage pattern was more diffusion based. No leakage was observed when dextran 500 kDa was used as a colloid osmotic agent. The results in this study suggest that fluorescence imaging could be used as a method for qualitative and semiquantitative molecular transport and fluid dynamics studies of MD membranes and other hollow fiber catheter membranes.
Similar content being viewed by others
References
Chaurasia CS (1999) In vivo microdialysis sampling: theory and applications. Biomed Chromatogr 13:317–332
Plock N, Kloft C (2005) Microdialysis—theoretical background and recent implementation in applied life-sciences. Eur J Pharm Sci 25:1–24
Ungerstedt U (1991) Microdialysis—principles and applications for studies in animals and man. J Intern Med 230:365–373
Ao XP, Stenken JA (2006) Microdialysis sampling of cytokines. Methods 38:331–341
Clough GF (2005) Microdialysis of large molecules. AAPS J 7:E686–E692
Rosdahl H, Hamrin K, Ungerstedt U, Henriksson J (2000) A microdialysis method for the in situ investigation of the action of large peptide molecules in human skeletal muscle: detection of local metabolic effects of insulin. Int J Biol Macromol 28:69–73
Schutte RJ, Oshodi SA, Reichert WM (2004) In vitro characterization of microdialysis sampling of macromolecules. Anal Chem 76:6058–6063
Pettersson A, Amirkhani A, Arvidsson B, Markides K, Bergquist J (2004) A feasibility study of solid supported enhanced microdialysis. Anal Chem 76:1678–1682
Clough GF, Jackson CF, Lee JJP, Jamal SC, Church MK (2007) What can microdialysis tell us about the temporal and spatial generation of cytokines in allergen-induced responses in human skin in vivo? J Invest Dermatol 127:2799–2806
Dahlin AP, Wetterhall M, Caldwell KD, Larsson A, Bergquist J, Hillered L, Hjort K (2010) Methodological aspects on microdialysis protein sampling and quantification in biological fluids: an in vitro study on human ventricular CSF. Anal Chem 82:4376–4385
Kjellstrom S, Appels N, Ohlrogge M, Laurell T, Marko-Varga G (1999) Microdialysis—a membrane based sampling technique for quantitative determination of proteins. Chromatographia 50:539–546
Chu JT, Hjort K, Larsson A, Dahlin AP (2014) Impact of static pressure on transmembrane fluid exchange in high molecular weight cut off microdialysis. Biomed Microdevices 16:301–310
Bungay PM, Wang TL, Yang H, Elmquist WF (2010) Utilizing transmembrane convection to enhance solute sampling and delivery by microdialysis. J Membr Sci 348:131–149
Dahlin AP, Hjort K, Hillered L, Sjodin MOD, Bergquist J, Wetterhall M (2012) Multiplexed quantification of proteins adsorbed to surface-modified and non-modified microdialysis membranes. Anal Bioanal Chem 402:2057–2067
Trickler WJ, Miller DW (2003) Use of osmotic agents in microdialysis studies to improve the recovery of macromolecules. J Pharm Sci 92:1419–1427
Kim KJ, Fane AG, Ben Aim R, Liu MG, Jonsson G, Tessaro IC, Broek AP, Bargeman D (1994) A comparative study of techniques used for porous membrane characterization: pore characterization. J Membr Sci 81:35–46
Keeler GD, Durdik JM, Stenken JA (2013) Comparison of microdialysis sampling perfusion fluid components on the foreign body reaction in rat subcutaneous tissue. Eur J Pharm Sci, in press. [Epub ahead of print; PMID: 24239995]
Lichtman JW, Conchello JA (2005) Fluorescent Microscopy. Nat Methods 2:910–919
Zhu XC, Xu L, Wu TB, Xu AQ, Zhao MP, Liu SR (2014) Continuous monitoring of bisulfide variation in microdialysis effluents by on-line droplet-based microfluidic fluorescent sensor. Biosens Bioelectron 55:438–445
Wang X, Stenken JA (2006) Microdialysis sampling membrane performance during in vitro macromolecule collection. Anal Chem 78:6026–6034
Bungay PM, Morrison PM, Dedrick RL (1990) Steady-state theory for quantitative microdialysis of solutes and water in vivo and in vitro. Life Sci 46:105–119
Dahlin AP, Wetterhall M, Liljegren G, Bergström SK, Andrén P, Nyholm L, Markides KE, Bergquist J (2005) Capillary electrophoresis coupled to mass spectrometry from a polymer modified poly(dimethylsiloxane) microchip with an integrated graphite electrospray tip. Analyst 130:193–199
Loan CE, Aberle T, Burchard W (2000) Structure Properties of Dextran. Macromol 33:5730–5739
Li Z, Hughes D, Urban JPG, Cui Z (2008) Effect of pumping methods on transmembrane pressure, fluid balance and relative recovery in microdialysis. J Membr Sci 310:237–245
Maurer MH, Berger C, Wolf M, Fütterer CD, Feldmann RE Jr, Schwab S, Kuschinsky W (2003) The proteome of human brain microdialysate. Proteome Sci 1:7–12
Pharmacosmos GPC standards (2014) Pharmacosmos. Available at: http://www.dextran.net. Accessed 28 Mar 2014. (Online document)
Pharmacosmos A/S batch release certificate, Dextran 60 EP, Batch no: 40013 (2006) Pharmacosmos. Available at: http://www.dextran.net. Accessed 6 Jan 2006. (Online document)
Acknowledgments
This research was in part supported by the Uppsala Berzelii Technology Centre for Neurodiagnostics, funded by the Swedish Governmental Agency for Innovation Systems and the Swedish Research Council Grant number P29797-1. The authors acknowledge mDialysis and Pharmacosomos AS for sharing their knowledge and for material support and Visualize your Science for graphical assistance.
Author information
Authors and Affiliations
Corresponding author
Electronic supplementary material
Below is the link to the electronic supplementary material.
ESM 1
(PDF 668 kb)
Rights and permissions
About this article
Cite this article
Chu, J., Koudriavtsev, V., Hjort, K. et al. Fluorescence imaging of macromolecule transport in high molecular weight cut-off microdialysis. Anal Bioanal Chem 406, 7601–7609 (2014). https://doi.org/10.1007/s00216-014-8192-y
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00216-014-8192-y