Skip to main content
Log in

Different bracket–archwire combinations for simulated correction of two-dimensional tooth malalignment

Leveling outcomes and initial force systems

Verschiedene Bracket-Drahtbogen-Kombinationen bei der simulierten Korrektur kombinierter Zahnfehlstellungen

Nivellierungseffektivität und initiale Kraftsysteme

  • Original article
  • Published:
Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie Aims and scope Submit manuscript

Abstract

Objectives

Self-ligating brackets are widely believed to be more effective in clinical use and to involve less friction and force. Thus, the goal of this in vitro investigation was to experimentally assess the effectiveness of different bracket–archwire combinations and the force levels exerted in two-dimensional direction during correction of tooth malalignment. An important aspect of this objective was to determine whether the behaviors of conventional bracket systems with an elastic or steel ligature differ from that of self-ligating brackets.

Materials and methods

Three conventional (Mini Taurus®, RMO; Synergy®, RMO; Victory Series™, 3M Unitek) and three self-ligating bracket systems (Speed™, Strite; Smart Clip™, 3M Unitek; Time 3, American Orthodontics) were analyzed. All brackets had 0.018-inch (0.46-mm) slots and—except for the self-ligating brackets—were tested with both a steel ligature (0.25 mm; Remanium, Dentaurum) and an elastic rubber ligature (1.3 mm in diameter; Dentalastics, Dentaurum). They were fitted with four different round wires: a 0.30-mm stainless steel (3M Unitek), 0.38-mm stainless steel coaxial (Advanced Orthodontics), 0.30-mm Thermalloy NiTi (RMO), and 0.30-mm Orthonol NiTi (RMO) archwire. The orthodontic measurement and simulation system (OMSS) was used to simulate a two-dimensional (2 mm of infraocclusion and 2 mm of vestibular displacement) malalignment of tooth 21 inserted in a resin replica of a Frasaco model. Four brackets of the same type were assessed and four individual measurements taken per bracket to analyze initial force systems and corrective malalignment outcomes.

Results

The initial force systems and tooth movements varied distinctly between the different material combinations in conjunction with the ligation systems and archwire types used. The force systems generated were readily reproducible across individual measurements. Leveling outcomes and force systems between conventional steel-ligated and self-ligating brackets coincided in most cases. Both of these device configurations corrected the malalignment by 78–99 % on average. Rubber-ligated conventional brackets, by contrast, performed significantly worse due to exertion of significantly higher forces and 60 % less of a leveling effect.

Conclusion

Our investigation demonstrates that both conventional steel-ligated brackets and self-ligating brackets, which are highlighted in the literature as highly efficient systems, lead to equivalent corrective outcomes in the treatment of tooth malalignments.

Zusammenfassung

Hintergrund und Ziel

Selbstligierenden Brackets wird häufig eine erhöhte klinische Effektivität, geringere Reibung sowie reduzierte Kraftgröße zugesprochen. Ziel dieser In-vitro-Untersuchung war es daher, die Nivellierungseffektivität sowie wirkende Nivellierungskräfte verschiedener Bracket-Drahtbogen-Kombinationen anhand einer vordefinierten kombinierten Zahnfehlstellung experimentell zu untersuchen. Dabei war ein wichtiger Aspekt festzustellen, ob sich die konventionellen Bracketsysteme mit der elastischen oder der Stahlligatur anders verhalten als die selbstligierenden Brackets.

Material und Methodik

Untersucht wurden 3 konventionelle (Mini Taurus®, RMO; Synergy®, RMO; Victory Series™, 3M Unitek) sowie 3 selbstligierende Bracketsysteme (Speed™, Strite; Smart Clip™, 3M Unitek; Time 3, American Orthodontics). Alle Brackets hatten einen 0,018-inch-Slot (0,46 mm) und wurden, mit Ausnahme der selbstligierenden Systeme, mit einer Stahlligatur (0,25 mm, Remanium, Dentaurum) und einer elastischen Gummiligatur (Ø 1,3 mm Dentalastics, Dentaurum) getestet. Folgende Runddrähte wurden verwendet: Edelstahldrahtbogen (0,30 mm, 3M Unitek), Koaxial-Stahl-Drahtbogen (0,38 mm, Advanced Orthodontics), Thermalloy- und Orthonol-Drahtbogen (beide 0,30 mm, RMO). Das OMSS (orthodontisches Mess- und Simulationssystem) diente zur Simulation einer vordefinierten, kombinierten Zahnfehlstellung (Infraokklusion sowie vestibuläre Verlagerung des Zahns 21 um jeweils 2 mm) am Kunststoffreplika eines Frasaco-Modells. Ermittelt wurden jeweils die initialen Kraftsysteme sowie die in der Simulation erreichte Zahnstellungskorrektur. Für jede Materialkombination wurden 4 Brackets vom gleichen Hersteller untersucht und jeweils 4 Einzelmessungen durchgeführt.

Ergebnisse

Initiale Kraftsysteme und erzielte Zahnbewegungen variierten deutlich bei den verschiedenen Materialkombinationen in Abhängigkeit vom verwendeten Ligatursystem sowie Drahtbogentyp. Die erzeugten Kraftsysteme waren in den Einzelmessungen jedoch gut reproduzierbar. Selbstligierende Brackets und stahlligierte konventionelle Bracketsysteme unterschieden sich in ihren Nivellierungs- sowie Kraftergebnissen nur in Einzelfällen signifikant voneinander. Beide Systeme korrigierten die kombinierte Zahnfehlstellung zu durchschnittlich 78–99 %. Gummiligierte konventionelle Brackets unterschieden sich dagegen meist signifikant von den beiden o. g. Bracketsystemen und zeigten merklich höhere Kräfte sowie eine durchschnittlich um 60 % geringerer Nivellierungseffektivität.

Schlussfolgerung

Nicht nur ist den in der Literatur häufig mit Vorteilen beworbenen selbstligierenden Bracketsystemen eine Präferenz auszusprechen, es können gleichwertige Korrekturergebnisse mit stahlligierten konventionellen Bracketsystemen erreicht werden.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6

References

  1. Bednar JR, Gruendemann GW, Sandrik JL (1991) A comparative study of frictional forces between orthodontic brackets and arch wires. Am J Orthod Dentofacial Orthop 100:513–522

    Article  PubMed  Google Scholar 

  2. Bourauel C, Drescher D, Thier M (1992) An experimental apparatus for the simulation of three-dimensional movements in orthodontics. J Biomed Eng 14:371–378

    Article  PubMed  Google Scholar 

  3. Bourauel C, Drescher D, Nolte LP (1993) Computergestützte Entwicklung kieferorthopädischer Behandlungselemente aus NiTi-Memory-Legierungen am Beispiel einer pseudoelastischen Retraktionsfeder. Fortschr Kieferorthop 54:45–56

    Article  PubMed  Google Scholar 

  4. Bourauel C, Fries T, Drescher D, Plietsch R (1998) Surface roughness of orthodontic wires via atomic force microscopy, laser specular reflectance and profilometry. Eur J Orthodont 20:79–92

    Article  Google Scholar 

  5. Drescher D, Bourauel C, Schumacher HA (1989) Frictional forces between bracket and arch wire. Am J Orthod Dentofac Orthop 96:397–404

    Article  Google Scholar 

  6. Drescher D, Bourauel C, Thier M (1990) Materialtechnische Besonderheiten orthodontischer Nickel-Titan-Drähte. Fortschr Kieferorthop 51:320–326

    Article  PubMed  Google Scholar 

  7. Drescher D, Bourauel C, Thier M (1991) Orthodontische Meß- und Simulationssystem (OMSS) für die statische und dynamische Analyse der Zahnbewegung. Fortschr Kieferorthop 52:133–140

    Article  PubMed  Google Scholar 

  8. Fansa M, Keilig L, Reimann S et al (2009) The leveling of effectivness of self-ligating and con ventional brackets for complex tooth malalignments. J Orofac Orthop 70:285–296

    Article  PubMed  Google Scholar 

  9. Frank CA (1979) An evaluation of frictional force generated between orthodontic bracket and arch wire. St. Louis University

  10. Frank CA, Nikolai RJ (1980) A comparative study of frictional resistances between orthodontic brackets and archwire. Am J Orthod 78:593–609

    Article  PubMed  Google Scholar 

  11. Girden ER (1992) ANOVA: repeated measures. Sage, Newbury Park

  12. Harradine NW (2001) Self-ligating brackets and treatment efficiency. Clin Orthod Res 4:220–227

    Article  PubMed  Google Scholar 

  13. Harradine NW (2003) Self-ligating brackets: where are we now? J Orthod 30:262–273

    Article  PubMed  Google Scholar 

  14. Matarese G, Nucera R, Militi A et al (2008) Evaluation of frictional forces during dental align-ment: an experimental model with 3 nonleveled brackets. Am J Orthod Dentofacial Orthop 133:708–715

    Article  PubMed  Google Scholar 

  15. Miles PG (2005) SmartClip versus conventional twin brackets for initial alignment: is there a difference? Aust Orthod J 21:123–127

    PubMed  Google Scholar 

  16. Miles PG, Weyant RJ, Rustveld L (2006) A clinical trial of Damon 2 vs conventional twin brackets during initial alignment. Angle Orthod 76:480–485

    PubMed  Google Scholar 

  17. Pandis N, Bourauel C, Eliades T (2007) Changes in the stiffness of the ligating mechanism in retrieved active self-ligating brackets. Am J Orthod Dentofac Orthop 132:834–837

    Article  Google Scholar 

  18. Pandis N, Polychronopoulou A, Eliades T (2007) Self-ligating vs conventional brackets in the treatment of mandibular crowding: a prospective clinical trial of treatment duration and dental effects. Am J Orthod Dentofacial Orthop 132:208–215

    Article  PubMed  Google Scholar 

  19. Reicheneder CA, Gedrange T, Berrisch S et al (2008) Conventionally ligated versus self-ligating metal brackets − a comparative study. Eur J Orthod 30:654–660

    Article  PubMed  Google Scholar 

  20. Schumacher HA, Bourauel C, Drescher D (1990) Der Einfluß der Ligatur auf die Friktion zwi-schen Bracket und Bogen. Fortschr Kieferorthop 51:106–116

    Article  PubMed  Google Scholar 

  21. Schumacher HA, Bourauel C, Drescher D (1991) Bogengeführte Zahnbewegung, Dynamik, Ef-fektivität und Nebenwirkungen. Fortschr Kieferorthop 52:141–152

    Article  PubMed  Google Scholar 

  22. Schumacher HA, Bourauel C, Drescher D (1992) Deaktivierungsverhalten und Effektivität ver-schiedener orthodontischer Nivellierungsbögen—eine dynamische Analyse der Kraft-systeme. Fortschr Kieferorthop 53:273–285

    Article  PubMed  Google Scholar 

  23. Schumacher HA, Bourauel C, Drescher D (1999) The influence of bracket design on frictional losses in the bracket/arch wire system. J Orofac Orthop 60:335–347

    Article  PubMed  Google Scholar 

  24. Scott P, DiBiase AT, Sherriff M, Cobourne MT (2008) Alignment efficiency of Damon3 self-ligating and conventional orthodontic bracket systems: a randomized clinical trial. Am J Orthod Dentofacial Orthop 134:470.e1–8

    Article  PubMed  Google Scholar 

  25. Tagawa D (2006) From good great. The Damon System vs. conventional appliances: a com-parative study. Clin Impressions 15:4–9

    Google Scholar 

  26. Tidy DC, Orth D (1989) Frictional force in fixed appliances. Am J Orthod Dentofac Orthop 96:249–254

    Article  Google Scholar 

  27. Weinberger GL (2005) Smart Clip Self-ligating appliance system utilization guide. 3M Unitek product literature 2005.

Download references

Compliance with ethical guidelines

Conflict of interest. S. Holtmann, A. Konermann, L. Keilig, S. Reimann, A. Jäger, M. Montasser, T. El-Bialy, and C. Bourauel state that there are no conflicts of interest. The accompanying manuscript does not include studies on humans or animals.

Einhaltung ethischer Richtlinien

Interessenkonflikt. S. Holtmann, A. Konermann, L. Keilig, S. Reimann, A. Jäger, M. Montasser, T. El-Bialy und C. Bourauel geben an, dass kein Interessenkonflikt besteht. Dieser Beitrag beinhaltet keine Studien an Menschen oder Tieren.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to C. Bourauel.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Holtmann, S., Konermann, A., Keilig, L. et al. Different bracket–archwire combinations for simulated correction of two-dimensional tooth malalignment. J Orofac Orthop 75, 459–470 (2014). https://doi.org/10.1007/s00056-014-0238-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00056-014-0238-4

Keywords

Schlüsselwörter

Navigation