Abstract
Neuromuscular blockade is controlled during anesthesia by administering either bolus doses or a continuous infusion of a blocking agent. To test whether a constant infusion technique requires less attention and provides better control we used a computer to simulate neuromuscular blockade. Using the model we maintained 95% blockade with mivacurium, atracurium, and vecuronium. It required 1.2 changes per hour to maintain the blockade by continuous infusion; an average of 4.5 bolus per hour were required to maintain blockade by the bolus technique. When the bolus and continuous infusion techniques were combined, only 0.16 changes per hour were required. Atracurium was then given to ten patients during anesthesia, following the bolus plus continuous infusion protocol. After a bolus was given to obtain 100% twitch depression, for tracheal intubation, neuromuscular function was assessed by train-of-four stimulation of the ulnar or facial nerves by observing the resultant muscle movement. When the first twitch of the train-of-four returned, relaxation was maintained by continuous infusion. A bolus was given and the drug infusion rate was changed whenever the level of relaxation changed from the desired one twitch of the train-of-four. The infusion rate was adjusted only 1.12±0.79 times per hour. The desired level of muscle relaxation was easily controlled using the bolus plus continuous infusion protocol. The infusion scheme might be implemented in future drug infusion pumps.
Article PDF
Similar content being viewed by others
References
Payne JP, Hughes R. Clinical assessment of neuromuscular transmission. Br J Pharmacol 1981; 11: 537.
Goth A. Medical Pharmacology. C.V. Mosby Co., 1961.
Goodman LS, Gilman A. The Pharmacological Basis of Therapeutics. 4th ed., Macmillan Co., 1970.
Spierdijk Joh, Schurink GA. Inleiding Anaesthesiologie. 2nd ed., Samson Stafleu., 1989.
Darrah WC, Johnston JR, Mirakhur RK. Vecuronium infusions for prolonged muscle relaxation in the intensive care unit. Crit Care Med 1989; 17: 1297–1309.
Katz RL. Muscle Relaxants: Basic and Clinical Aspects. Grune & Stratton, 1985: 87–117.
Ali HH, Savarese JJ, Embree PB, Basta SJ, Stout RG, Bottros LH, Weakly JN. Clinical pharmacology of mivacurium chloride (BW B109U) infusion: comparison with vecuronium and the intermittent administration of pancuronium and vecuronium. Br J Anaesth 1988; 61: 541–6.
Jaklitsch RR, Westenskow DR. A simulation of neuromuscular function and heart rate during induction, maintenance, and reversal of neuromuscular blockade. J Clin Monit 1990; 6: 24–38.
Noeldge G, Hinsken H, Buzello W. Comparison between the continuous infusion of vecuronium and the intermittent administration of pancuronium and vecuronium. Br J Anaesth 1984; 56: 473–7.
Viby-Mogensen J. Clinical assessment of neuromuscular transmission. Br J Anaesth 1982; 54: 209–23.
Ali HH, Utting JE, Gray C. Stimulus frequency in the detection of neuromuscular block in humans. Br J Anaesth 1970; 42: 967–76.
Savarese JJ, Ali HH, Basta SJ, et al. The clinical neuromuscular pharmacology of mivacurium chloride (BW B109U). Anesthesiology 1988; 68: 723–32.
Schwilden H, Schuttler J, Stoekel H. Pharmacokinetics as applied to total intravenous anesthesia. Theoretical considerations. Anesthesia 1983; 38: 51–2.
Alvis JM, Reves JG, Govier AV, Menkhaus PG, Henling CE, Spain JA, Rradley E. Computer-assisted continuous infusions of fentanyl during cardiac anesthesia: Comparison with manual method. Anesthesiology 1985; 63: 41–9.
Alvis JM, Reves JG, Spain JA, Sheppard LC. Computer-assisted continuous infusion of the intravenous analgetic fentanyl during general anesthesia. An interactive system. IEEE Trans Biomed Eng 1985; BME-32, no.5.