Background

Knee arthrodeses are performed to treat infection after arthroplasty and tumors requiring extensive soft tissue resection. Many techniques have been described, but most have important disadvantages. Currently, endoprosthetic arthrodesis implants are available, but little is known about them.

Questions/purposes

Our objective was to analyze a series of knee arthrodeses with a modular prosthetic system to evaluate (1) survivorship of the implant, (2) complications, (3) whether survivorship differed between arthrodeses done for primary tumor resection and revision reconstructions, and (4) whether survivorship differed based on the presence of previous infection or the use of a gastrocnemius flap.

Methods

We present 32 patients with modular knee arthrodeses; arthrodeses were performed in 25 patients with tumors and in seven patients without tumors. There were 14 implants done at the time of tumor resection and 18 for revision of failed implants. Survivorship and complications were analyzed with Kaplan-Meier curves. Log-rank test was used for comparison between primary and revision implants, not infected and previously infected implants, and use or nonuse of a gastrocnemius flap.

Results

Survivorship of arthrodeses with modular endoprostheses was 50% and 25% at 5 and 10 years, respectively. There were nine infections (29%) and one implant fracture (3%). Amputation as final surgery was required in 8 patients (six owing to infection and two to oncologic failures). There was no significant difference in survivorship between arthrodeses done for primary tumor resection and as a salvage procedure for failed implants. No differences were found between patients with and without prior infection or with and without a gastrocnemius flap.

Conclusions

Survivorship of a modular arthrodesis implant was 50% at 5 years owing to a high complication rate. Infection is the most common cause of failure of oncologic and revision implants. Implant fracture is a rare occurrence. Modular segmental arthrodesis provides a stable construct for patients in whom limb preservation is possible but a hinged device is contraindicated as a result of major muscle resection.

Level of Evidence

Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

Each author certifies that he or she, or a member of his or her immediate family, has no funding or commercial associations (eg, consultancies, stock ownership, equity interest, patent/licensing arrangements, etc) that might pose a conflict of interest in connection with the submitted article.
All ICMJE Conflict of Interest Forms for authors and Clinical Orthopaedics and Related Research editors and board members are on file with the publication and can be viewed on request.
Clinical Orthopaedics and Related Research neither advocates nor endorses the use of any treatment, drug, or device. Readers are encouraged to always seek additional information, including FDA-approval status, of any drug or device prior to clinical use.
Each author certifies that his or her institution approved the human protocol for this investigation, that all investigations were conducted in conformity with ethical principles of research, and that informed consent for participation in the study was obtained.