Abstract

Background

We designed a study to compare ventilation characteristics performed in morbidly obese patients by medical students via the facemask to that via the LMA Supreme®.

Methods

This prospective, randomized, crossover study included 31 ASA I–III morbidly patients showing difficult mask ventilation predictors. After induction of anesthesia, ten medical students with no previous clinical experience in airway management, clinically educated to facemask ventilation maneuvers, and theoretically educated to laryngeal mask use were supervised by a senior anesthesiologist during performance of 60 s facemask and LMA Supreme® ventilation in a randomly assigned order. Ventilation quality and difficulty were measured using an original score calculated as the sum of seven indicators (0 = no ventilation and complications, 12 = optimal and safe ventilation) and a visual analog scale (VAS; 0 = no difficult–100 = impossible), respectively. Values are presented as means (standard deviation) or medians [extremes].

Results

Mean age and body mass index of the patients were 39 years (12 years) and 44 kg m−2 (7 kg m−2), respectively. One patient was excluded because of ventilation difficulty experienced by the senior anesthesiologist. Medical students successfully established ventilation with the LMA Supreme® in all the 30 patients after a delay of 21 s (9 s) compared to 34 s (14 s) with the facemask (P < 0.05). Failure of ventilation occurred in four patients with the facemask. Ventilation quality score was superior and ventilation difficulty (VAS 0–100) was inferior with the LMA Supreme® than with the facemask (11 [10–12] and 9 [0–45] versus 5 [1–12] and 50 [5–100]); both P < 0.05, respectively.

Conclusions

We showed that the LMA Supreme™ placed in novice hands systematically promoted easier ventilation of better quality than the facemask in morbidly obese patients showing difficult mask ventilation predictors. Our data suggest that the LMA Supreme™ could be considered as a standard airway management tool for both elective and rescue airway management of morbidly obese patients.

Keywords

LMA Facemask Difficult ventilation Morbidly obese patients 

Copyright information

© Springer Science + Business Media, LLC 2009

Authors and Affiliations

  • Widad Abdi
    • 1
  • Gilles Dhonneur
    • 1
    • 3
  • Roland Amathieu
    • 1
  • Anis Adhoum
    • 1
  • Walid Kamoun
    • 1
  • Velislav Slavov
    • 1
  • Christophe Barrat
    • 2
  • Xavier Combes
    • 1
  1. 1.Anesthesia Department and Airway Management (Paris 13), University Diploma GroupParis 13 School of MedicineBobignyFrance
  2. 2.Department of Visceral Surgery, Morbid Obesity Surgery UnitJean Verdier University Hospital of Paris (APHP)BondyFrance
  3. 3.Département d’Anesthésie et Réanimation CHU (APHP)Jean VerdierBondyFrance

Personalised recommendations