Skip to main content
Log in

A simple model for predicting the effect of hygrothermal conditions on populations of house dust mite Dermatophagoides pteronyssinus (Acari: Pyroglyphidae)

Experimental & Applied Acarology Aims and scope Submit manuscript

Abstract

A simple mite population index (MPI) model is presented which predicts the effect on house dust mite populations of any combination of temperature and relative humidity (RH). For each combination, the output is an index, or multiplication factor, such that 1.1 indicates 10% population growth and 0.9 indicates 10% population decline. To provide data for the model, laboratory experiments have been carried out using lab cultures of Dermatophagoides pteronyssinus. The population change was observed for mites held in steady-state conditions at different combinations of temperature and RH over 21 days. From the results, a best-fit equation has been derived which forms the basis of the MPI model. The results also enable a new term to be defined: the Population Equilibrium Humidity, PEH, the RH for a given temperature at which house dust mite populations neither grow nor decline. It is similar to Critical Equilibrium Humidity, the RH below which house dust mites are unable to maintain water balance, but relates to a population of mites (rather than a physiological phenomenon) and is more able to take account of the observed effects of extremes of temperature and RH. Compared with previous population models, the MPI model is potentially more accurate and comprehensive. It can be combined with other simple models (described in previous papers), such as BED, which simulates the average hygrothermal conditions in a bed, given room␣conditions, and Condensation Targeter II, which simulates room conditions given a range of easily obtainable inputs for climate, house type and occupant characteristics. In this way it is now possible, for any individual dwelling, to assess the most effective means of controlling mite populations by environmental means, such as by improving standards of ventilation and insulation, or by modifying the occupant behaviour that affects the hygrothermal environment within a dwelling. Although the MPI model requires further development and validation, it has already proved useful for understanding more clearly how the different hygrothermal conditions found in beds and bedrooms can affect mite populations. It has also demonstrated that there is considerable scope for controlling mites by environmental means in cold winter climates such as the UK.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

References

  • Arlian LG (1975) Dehydration and survival of the European house dust mite, Dermatophagoides pteronyssinus. J Med Entomol 12/4:437–442

  • Arlian LG (1992) Water balance and humidity requirements of house dust mites. Exp Appl Acarol 16:15–35

    Article  PubMed  CAS  Google Scholar 

  • Arlian LG, Veselica MM (1979) Water balance in insects and mites. Comp Biochem Physiol 64A:191–200

    Article  Google Scholar 

  • Arlian LG, Veselica MM (1981a) Effect of temperature on the equilibrium body water mass in the mite Dermatophagoides farinae. Physiol Zool 54/4:393–399

    Google Scholar 

  • Arlian LG, Veselica MM (1981b) Re-evaluation of the humidity requirements of the house dust mite Dermatophagoides farinae (Acari: Pyroglyphidae). J Med Entomol 18/4:351–352

    Google Scholar 

  • Arlian LG, Wharton GW (1974) Kinetics of active and passive components of water exchange between the air and a mite, Dermatophagoides farinae. J Insect Physiol 20:1063–1077

    Article  PubMed  CAS  Google Scholar 

  • Arlian LG, Rapp CM, Ahmed SG (1990) Development of Dermatophagoides pteronyssinus (Acari: Pyroglyphidae). J Med Entomol 27/6:1035–1040

    PubMed  CAS  Google Scholar 

  • van Asselt L (1999) Interactions between domestic mites and fungi. Indoor Built Environ 8:216–220

    Google Scholar 

  • de Boer R (2000a) Rates of water vapour uptake and loss by the house dust mite, Dermatophagoides pteronyssinus (Acari: Pyroglyphidae). Proc Exp Appl Entomol 11:73–76

    Google Scholar 

  • de Boer R (2000b) Explaining house dust mite infestations on the basis of temperature and air humidity measurements. In: Siebers R, Cunningham M, Fitzharris P and Crane J (eds) Mites, asthma and domestic design III. Wellington Asthma Research Group, Department of Medicine, Otago University, 2000

  • de Boer R, Kuller K (1997) Mattresses as a winter refuge for house-dust mite populations. Allergy 52:299–305

    Article  PubMed  Google Scholar 

  • de Boer R, Kuller K, Kahl O (1998) Water balance of Dermatophagoides pteronyssinus (Acari: Pyroglyphidae) maintained by brief daily spells of elevated air humidity. J Med Entomol 35/6:905–910

    PubMed  Google Scholar 

  • van Bronswijk JE (1981) House dust biology for allergists, acarologists and mycologists. NIB Publishers, The Netherlands

    Google Scholar 

  • Charpin D, Kleisbauer J, Lanteaume A, Razzouk H, Vervloet D, Toumi M, Faraj F, Charpin J (1988) Asthma and allergy to house-dust mites in populations living in high altitudes. Chest 93:758–761

    Article  PubMed  CAS  Google Scholar 

  • Colloff M (1991) Practical and theoretical aspects of the ecology of house dust mites (Acari: Pyroglyphidae) in relation to the study of mite-mediated allergy. Rev Med Vet Entomol 79(11/12):611–630

    Google Scholar 

  • Colloff M (1992) Age structure and dynamics of house dust mite populations. Exp Appl Acarol 16:49–74

    Article  Google Scholar 

  • Colloff M (1994) Dust mite control and mechanical ventilation: when the climate is right. Clin Exp Allergy 24:94–96

    Article  PubMed  CAS  Google Scholar 

  • Cunningham MJ (1996) Controlling dust mites psychrometrically – a review for scientists and engineers. Indoor Air 6:249–258

    Article  CAS  Google Scholar 

  • Cunningham MJ (1998) Development and performance of a small relative humidity sensor for indoor microclimate measurements. Build Environ 34:349–352

    Article  Google Scholar 

  • Cunningham MJ (1999) Modelling of some dwelling internal microclimates. Build Environ 34:523–536

    Article  Google Scholar 

  • Cunningham MJ (2000) A proposed experimental programme towards control of dust mites by microclimate modification. In: Siebers R, Cunningham M, Fitzharris P, Crane J (eds) Mites, asthma and domestic design III. Wellington Asthma Research Group, Department of Medicine, Otago University, 2000

  • Fletcher A, Pickering CA, Custovic A, Simpson J, Kennaugh J, Woodcock A (1996) Reduction in humidity as a method of controlling mites and mite allergens: the use of mechanical ventilation in British domestic dwellings. Clin Exp Allergy 26:1051–1056

    Article  PubMed  CAS  Google Scholar 

  • Gamal-Eddin F, Shehata K, Abou-Sinna F, Tayel S, Aboul-Atta A, El-Ahmedaawy B-E, Fayed M, Hafez A, Imam M (1983) Duration and the development stages of house-dust mites Dermatophagoides farinae and D. pteronyssinus under controlled conditions to pave the way in front of the workers in the field of house-dust mite asthmatic bronchitis. 2 Oviposition period, fecundity and oval duration. J Egypt Soc Parasitol 13:557–581

    PubMed  CAS  Google Scholar 

  • Hart BJ, Whitehead L (1990) Ecology of house dust mites in Oxfordshire. Clin Exp Allergy 20:203–209

    Article  PubMed  CAS  Google Scholar 

  • Harving H, Hansen L, Korsgaard J, Nielsen P, Olsen O, Rømer J, Svendsen U, østerballe O (1991) House dust mite allergy and anti-mite measures in the indoor environment. Allergy 46/S11:33–38

    Article  PubMed  Google Scholar 

  • Harving H, Korsgaard J, Dahl R (1994) Clinical efficacy of reduction in house-dust mite exposure in specially designed, mechanically ventilated “healthy” homes. Allergy 49:866–870

    Article  PubMed  CAS  Google Scholar 

  • Hay DB, Hart BJ, Pearce RB, Kozakiewicz Z, Douglas AE (1992) How relevant are house dust mite-fungal interactions in laboratory culture to the natural dust system? Exp Appl Acarol 16:37–47

    Article  PubMed  CAS  Google Scholar 

  • Korsgaard J (1979) Husstøvmider (Pyroglyphidae, Acari) i danske boliger [House dust mites (Pyroglyphidae, Acari) in Danish homes]. Ugeskr Laeger 141:882–892

    Google Scholar 

  • Korsgaard J (1983a) Mite asthma and residency. Am Rev Respir Dis 128:231–235

    CAS  Google Scholar 

  • Korsgaard J (1983b) House-dust mites and absolute indoor humidity. Allergy 38:85–92

    Article  CAS  Google Scholar 

  • Korsgaard J, Iversen M (1991) Epidemiology of house dust mite allergy. Allergy 46(Suppl 11):14–18

    Article  PubMed  Google Scholar 

  • Kuehr J, Frischer T, Karmaus W, Meinert R, Barth R, Schraub S, Daschner A, Urbanek R, Forster J (1994) Natural variation in mite antigen density in house dust and relationship to residential factors. Clin Exp Allergy 24:229–237

    Article  PubMed  CAS  Google Scholar 

  • Larson DG (1969) The critical equilibrium activity of adult females of the house dust mite Dermatophagoides farinae Hughes. Ph.D. Thesis, Ohio State University, Columbus, Ohio

  • Lowe RJ (2000) Psychrometric control of dust mites in UK housing. Build Serv Eng Res Technol 21/4:274–276

    Google Scholar 

  • Luczynska C, Sterne J, Bond J, Azima H, Burney P (1998) Indoor factors associated with concentrations of house dust mite allergen, Der p 1, in a random sample of houses in Norwich, UK. Clin Exp Allergy 28:1201–1209

    Article  PubMed  CAS  Google Scholar 

  • McIntyre D (1992) The control of house dust mites by ventilation: a pilot study. Proceedings of 13th AIVC Conference: Ventilation for Energy Efficiency and Optimum Indoor Air Quality, 15–18 September 1992, Nice, France, Oscar Faber plc on behalf of International Energy Agency

  • Niven R, Fletcher A., Pickering A, Custovic A, Sivour J, Preece A, Oldham L, Francis H (1999) Attempting to control mite allergens with mechanical ventilation and dehumidification in British houses. J Allergy Clin Immunol 103:756–762

    Article  PubMed  CAS  Google Scholar 

  • Oreszczyn T, Pretlove S (1999) Condensation targeter II: modelling surface relative humidity to predict mould growth in dwellings. Build Serv Eng Res Technol 20/3:143–153

    Article  Google Scholar 

  • Pike A, Cunningham M, Lester P (2005) Development of Dermatophagoides pteronyssinus (Acari: Pyroglyphidae) at constant and simultaneously fluctuating temperature and humidity conditions. J Med Entomol 42/3:266–269

    Article  PubMed  CAS  Google Scholar 

  • Platts-Mills T, de Weck A (1987) Dust mite allergens and asthma – a world wide problem. Report on International Workshop, Bad Kreuznach, September (1987). J Allergy Clin Immunol 83:416–427

  • Pretlove S, Ridley I, Horwood J, Leung B, Cox P, Thomson D, Baker N, Crowther D, Oreszczyn T (2001) A combined transient hygrothermal and population model of house dust mites in beds. Proceedings of IAQ 2001: Moisture, Microbes and Health Effects: Indoor Air Quality and Moisture in Buildings, ASHRAE, San Francisco, USA, November 4–7, 2001

  • Pretlove S, Critchley R, Howard R, Oreszczyn T (2002) The Nottingham energy, health and houseing study: reducing relative humidity, dust mites and asthma. Build Serv Eng Res Technol 23/1:43–55

    Article  Google Scholar 

  • Pretlove S, Oreszczyn T, Ridley I, Wilkinson T, Crowther D (2005) A steady state model for predicting hygrothermal conditions in beds in relation to house dust mite requirements. Build Serv Eng Res Technol 26/4:301–314

    Article  Google Scholar 

  • Raw G, Weich C, Crump D, Brown V, Hunter C, Frederick J, Warner J, McIntyre D, Stephen F, Lane A (1998) Asthma, dust mites, ventilation and air quality: a field study of an environmental approach to reducing asthma. BRE Note N21/98, Building Research Establishment, Garston, UK

  • Sporik R, Chapman M, Platts-Mills T (1992) House dust mite exposure as a cause of asthma. Clin Exp Allergy 22:897–906

    Article  PubMed  CAS  Google Scholar 

  • van Strien R, Verhoeff A, Brunekreef B, van Wijnen J (1994) Mite antigen in house dust: relationship with different housing characteristics. Clin Exp Allergy 24:843–853

    Article  Google Scholar 

  • Sundell J, Wickman M, Pershagen G, Nordvall S (1995) Ventilation in homes infested by house-dust mites. Allergy 50:106–112

    Article  PubMed  CAS  Google Scholar 

  • Vervloet D, Pradal M, Porri F, Charpin D (1991) The epidemiology of allergy to the house dust mite. Revue des Maladies Respiratoires 8:59–65

    PubMed  CAS  Google Scholar 

  • Voorhorst R, Spieksma F, Varekamp H (1969) House dust atopy and the house dust mite, Dermatophagoides pteronyssinus (Trouessart, 1897). Stafleu’s Scientific Publishing Company, Leiden

    Google Scholar 

  • Warner J, Frederick J, Bryant T, Weich C, Raw G, Hunter C, Stephen F, McIntyre D, Warner J (2000) Mechanical ventilation and high efficiency vacuum cleaning: a combined strategy of mite and mite allergen reduction in the control of mite-sensitive asthma. J Allergy Clin Immunol 106:75–82

    Article  Google Scholar 

  • Wharton G (1978) Uptake of water vapour by mites and mechanisms utilized by the Acaridae. In: Schmidt-Nielsen K, Bolis L, Maddrell S (eds) Comparative physiology: water, ions and fluid mechanics. Cambridge University Press, Cambridge

    Google Scholar 

  • Wickman M, Emenius G, Egmar A-C, Axelsson G, Pershagen G (1994) Reduced mite allergen levels in dwellings with mechanical exhaust and supply ventilation. Clin Exp Allergy 24:109–114

    Article  PubMed  CAS  Google Scholar 

  • Winston P, Bates D (1960) Saturated solutions for the control of humidity in biological research. Ecology 40/1:232–237

    Article  Google Scholar 

Download references

Acknowledgements

This research project has been funded by the UK Engineering and Physical Sciences Research Council. We are also grateful for the editorial assistance provided by Dr. Barbara Hart (Royal Agricultural College, Cirencester)

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to David Crowther.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Crowther, D., Wilkinson, T., Biddulph, P. et al. A simple model for predicting the effect of hygrothermal conditions on populations of house dust mite Dermatophagoides pteronyssinus (Acari: Pyroglyphidae). Exp Appl Acarol 39, 127–148 (2006). https://doi.org/10.1007/s10493-006-9003-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10493-006-9003-8

Keywords

Navigation