Original Article

Osteoporosis International

, Volume 12, Issue 11, pp 936-941

The Temporal Changes of Trabecular Architecture in Ovariectomized Rats Assessed by MicroCT

  • A. LaibAffiliated withMagnetic Resonance Science Center, Department of Radiology
  • , J. L. KumerAffiliated withDivision of Rheumatology, Department of Medicine, University of California, San Francisco, California, USA
  • , S. MajumdarAffiliated withMagnetic Resonance Science Center, Department of Radiology
  • , N. E. LaneAffiliated withDivision of Rheumatology, Department of Medicine, University of California, San Francisco, California, USA

Rent the article at a discount

Rent now

* Final gross prices may vary according to local VAT.

Get Access

Abstract:

To study the short- and long-term effects of estrogen deficiency on trabecular bone, three-dimensional measurements of proximal tibiae of ovariectomized rats were performed by micro-computed tomography (MicroCT). New three-dimensional (3D) techniques were employed to characterize the trabecular architecture from 0 to 110 days post-ovariectomy (OVX). These new methods no longer assume a plate or rod model of bone, but calculate trabecular thickness, separation, and number and their distribution by placing maximal spheres into the 3D representation of the structure. The model type of bone was quantified with the Structure Model Index (SMI). Utilizing these methods we found a rapid loss of trabecular bone in the first week after OVX. After the first week bone mass declined further, although the rate of loss was lower. In addition there was a complete change in model type from plate-like to rod-like within 7 days post-OVX, and then a very constant SMI after 12 days. After an initial thinning of trabecular structure, further bone loss seems to occur through removal of trabeculae, while the trabecular plate thickness remains constant. The heterogeneity of the network could be quantified by intra-individual standard deviation of local separations, which showed a stair-like progression, with a plateau between 12 and 60 days post-OVX. This study provides new insights into ovariectomy-related changes in cancellous bone structure evaluated by 3D MicroCT. In addition, these data suggest that the rapid change of model from plate-like to rod-like post-OVX may potentially introduce biases in the parameters that are determined using model-based algorithms, and these biases may modify the impact of age-related or therapeutic changes.

Key words:3D architecture – Micro-computed tomography – Ovariectomy – Trabecular bone