Electroretinographic responses obtained from carriers of achromatopsia revealed a selective a-wave abnormality. Low a-wave amplitudes were found throughout the course of thirty minutes of dark adaptation. Color vision as well as subjective and objective CFF were normal. This is the first report of functional studies in the carrier state of X-linked recessive achromatopsia.

Résumé

Les réponses électrorétinographiques dans les conductrices d'achromatopsie liées au sexe revèlent une anomalie sélective sous forme d'une onde-a très réduite pendant l'adaptation à l'obscurité pour une période de 30 minutes.

La vision de couleur était parfaitement normale ainsi que la fréquence critique de fusion subjective et objective. C'est le premier rapport des études de fonction des conductrices d'achromatopsie liées au sexe.

Zusammenfassung

Das Elektroretinogramm von Konduktrizen von Achromatopsie zeigte selektive a-Wellen Abnormalität. Niedrige a-Wellen Amplituden wurden während 30 Minuten Dunkeladaptation gefunden. Das Farbensehen sowie die subjektive und objektive Flimmerverschmelzungsfrequenz waren normal. Dies ist der erste Bericht über Funktionsuntersuchungen bei Konduktrizen von X-gebundener rezessiver Achromatopsie.