Abstract
This paper describes a wearable mobihealth care system aiming at providing long-term continuous monitoring of vital signs for high-risk cardiovascular patients. We use a portable patient unit (PPU) and a wearable shirt (WS) to monitor electrocardiogram (ECG), respiration (acquired with respiratory inductive plethysmography, RIP), and activity. Owing to integrating fabric sensors and electrodes endowed with electro-physical properties into the WS, long-term continuous monitoring can be realized without making patients feel uncomfortable and restricting their mobility. The PPU analyzes physiological signals in real time and determines whether the patient is in danger or needs external help. The PPU will alert the patient and an emergency call will be automatically established with a medical service center (MSC) when life-threatening arrhythmias or falls are detected. With advanced gpsOne technology, the patient can be located and rescued immediately whether he/she is indoors or outdoors in case of emergency.
Similar content being viewed by others
References
Anliker U, Ward JA, Lukowicz P, Troster G, Dolveck F, Baer M, Keita F, Schenker EB, Catarsi F, Coluccini L, Belardinelli A, Shklarski D, Menachem A, Hirt E, Schmid R, Vuskovic M (2004) Amon: A wearable multiparameter medical monitoring and alert system. IEEE Trans Inform Technol Biomed 8(4):415–427
Ayesta U, Serrano L, Romero I (2001) Complexity measure revisited: a new algorithm for classifying cardiac arrhythmias. In: Proceedings of the 23rd annual international conference IEEE-EMBS 2:1589–1591
Body Media. http://www.bodymedia.com
Christov I, Dotsinsky I, Daskalov I (1992) High pass filtering of ECG signals using QRS elimination. Med Biol Eng Comput 30:253–256
Clarenbach CF, Senn O, Brack T, Kohler M, Bloch KE (2005) Monitoring of ventilation during exercise by a portable respiratory inductive plethysmograph. Chest 128:1282–1290
Cohen KP, Panescu D, Booske JH, Webster JG, Tompkins WJ (1994) Design of an inductive plethysmograph for ventilation measurement. Physiol Meas 15(2):217–229
Dotsinsky I, Stoyanov T (2005) Power-line interference cancellation in ECG signals. Biomed Instrum Technol 39(2):155–162
Epi- medics. http://epi-medics.insa-lyon.fr/flash/epimedics.html
EP Limited. Open source arrhythmia detection software, http://eplimited.com/software.htm
Fensli R, Gunnarson E, Gundersen T (2005) A wearable ECG-recording system for continuous arrhythmia monitoring in a wireless tele-home-care situation. In: Proceedings of the 18th symposium on CBMS, pp. 407–412
Lagerholm M, Peterson C (2000) Clustering ECG complex using hermite function and self-organizing maps. IEEE Trans Biomed Eng 47(7):838–848
Levkov C, Mihov G, Ivanov R, Daskalov I, Christov I, Dotsinsky I (2005) Removal of power-line interference from the ECG: a review of the subtraction procedure. Biomed Eng Online 4:50 DOI 10.1186/1475-925X-4-50
Lifeguard. http://www.lifeguard.stanford.edu
Mathie MJ, Basilakis J, Celler BG (2001) A system for monitoring posture and physical activity using accelerometers. In: Proceedings of the 23rd annual international conference IEEE-EMBS 4:3654–3657
Mathie MJ, Lovell NH, Coster ACF, Celler BG (2002) Determining activity using a triaxial accelerometer. In: Proceedings of the second joint conference EMBS/BMES 3:2481–2482
Martin T, Jovanov E, Raskovic D (2000) Issues in wearable computing for medical monitoring applications: A case study of a wearable ecg monitoring device. In: Proceedings of the 4th IEEE international symposium on wearable computers (ISWC’00), pp 43–49
Paradiso R (2003) Wearable health care system for vital signs monitoring. In: Proceedings of the fourth international conference IEEE-EMBS on information technology applications in biomedicine, pp 283–286
Park S, Jayaraman S (2003) Enhancing the quality of life through wearable technology. IEEE Eng Med Biol Mag 22(3):41–48
Polar watches. http://www.polarusa.com
Rodriguez J, Goni A, Illarramendi A (2005) Real-time classification of ECGs on a PDA. IEEE Trans Inform Technol Biomed 9(1):23–34
So HH, Chan KL (1997) Development of QRS detection method for real-time ambulatory cardiac monitor. In: Proceedings of the 19th annual international conference IEEE-EMBS 1:289–292
Spinelli EM, Pallas-Areny R, Mayosky MA (2003) AC-coupled front-end for biopotential measurements. IEEE Trans Biomed Eng 50:391–395
Vitaphone. http://www.vitaphone.de
Wilhelm FH, Handke E, Roth WT (2002) Measurement of respiratory and cardiac function by the LifeShirtTM: initial assessment of usability and reliability during ambulatory sleep monitoring. Biol Psychol 59:250–251
Zhang ZB, Yu MS, Li RX, Wu TH, Wu JL (2006) Design of a wearable respiratory inductive plethysmograph and its applications (in chinese). Space Med Med Eng 19(5):377–381
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Zheng, J.W., Zhang, Z.B., Wu, T.H. et al. A wearable mobihealth care system supporting real-time diagnosis and alarm. Med Bio Eng Comput 45, 877–885 (2007). https://doi.org/10.1007/s11517-007-0221-y
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11517-007-0221-y