Abstract
Purpose
To evaluate the efficiency of the form PWV/ABI (pulse wave velocity/ankle brachial pressure index) for measuring penile blood pressure (PBP) and the penile brachial pressure index (PBI).
Methods
We measured PBP and the PBI using both form PWV/ABI and Doppler ultrasonography in 40 men with surgical disorders.
Results
By using pulse-volume recording, the form PWV/ABI can simultaneously measure PBP and bilateral brachial artery pressure, and calculate the PBI automatically. The data obtained showed strong correlations with those obtained by the conventional Doppler ultrasound technique. Moreover, measurements were completed within 5 min at the bedside and the data were stored in the device's memory.
Conclusion
The form PWV/ABI is a useful tool for assessing pelvic hemodynamics and diagnosing vasculogenic impotence.
Similar content being viewed by others
References
LA Queral WM Whitehause SuffixJr WR Flinn CK Zarins JJ Bergan JST Yao (1979) ArticleTitlePelvic hemodynamics after aorto-iliac reconstruction Surgery 86 799–809 Occurrence Handle1:STN:280:Bi%2BD1c3gt1Q%3D Occurrence Handle515949
M Kawai (1988) ArticleTitlePelvic hemodynamics before and after aortoiliac vascular reconstruction: the significance of penile blood pressure Jpn J Surg 18 514–20 Occurrence Handle1:STN:280:BiaC2MjosFY%3D Occurrence Handle3230725
M Jevtich (1980) ArticleTitleImpotence of penile arterial pulse sound examination J Urol 124 820–4 Occurrence Handle1:STN:280:Bi6D2s3ltVU%3D Occurrence Handle7441831
PH Lin RL Bush EL Chaikof C Chen B Conklin TT Terramani et al. (2002) ArticleTitleA prospective evaluation of hypogastric artery embolization in endovascular aortoiliac aneurysm repair J Vasc Surg 36 500–6 Occurrence Handle10.1067/mva.2002.127350 Occurrence Handle12218973
V Ruzbarsky V Michal (1977) ArticleTitleMorphologic chances of the arterial bed of the penis with aging Invest Urol 15 194–9 Occurrence Handle1:STN:280:CSeD28njtFw%3D Occurrence Handle591264
P Metz (1987) ArticleTitleArteriogenic erectile impotence Dan Med Bull 33 134–50
GA Broderick (1998) ArticleTitleEvidence based assessment of erectile dysfunction Int J Impot Res 10 S64–73 Occurrence Handle9647964
JE Morley SG Korenman FE Kaiser AD Mooradian SP Viosca (1988) ArticleTitleRelationship of penile brachial pressure index to myocardial infarction and cerebrovascular accidents in older men Am J Med 84 445–8 Occurrence Handle1:STN:280:BieC287htFA%3D Occurrence Handle2964781
KR Kedia (1983) ArticleTitlePenile plethysmography useful in diagnosis of vasculogenic impotence Urology 22 235–9 Occurrence Handle10.1016/S0090-4295(83)80003-X Occurrence Handle1:STN:280:BiuD3MfpslM%3D Occurrence Handle6623767
RG DePalma HA Emsellem CM Edwards EM Druy SW Shultz HC Miller et al. (1987) ArticleTitleA screening sequence for vasculogenic impotence J Vasc Surg 5 228–36 Occurrence Handle10.1067/mva.1987.avs0050228 Occurrence Handle1:STN:280:BiiC2c7kt1A%3D Occurrence Handle3820400
S Yanagi T Kotake K Yamaguchi H Ito (1990) ArticleTitleRole of pulse volume recording in the evaluation of penile blood flow (in Japanese) Nippon Hinyokika Zasshi 81 1513–7 Occurrence Handle1:STN:280:By6C3cbhsFQ%3D
P Lavoisier R Barbe M Gally (2002) ArticleTitleValidation of a continuous penile blood-flow measurement by pulse-volume-plethysmography Int J Impot Res 14 116–20 Occurrence Handle10.1038/sj.ijir.3900840 Occurrence Handle1:STN:280:DC%2BD383ktVCgtQ%3D%3D Occurrence Handle11979327
RF Kempczinski (1979) ArticleTitleRole of vascular diagnostic laboratory in evaluation of male impotence Am J Surg 138 278–82 Occurrence Handle10.1016/0002-9610(79)90386-6 Occurrence Handle1:STN:280:CSaB38blslI%3D Occurrence Handle464231
RC-J Chiu D Lidstone PE Blundell (1986) ArticleTitlePredictive power of penile/brachial index in diagnosing male sexual impotence J Vasc Surg 4 251–6 Occurrence Handle10.1067/mva.1986.avs0040251 Occurrence Handle1:STN:280:BimA3cfislA%3D Occurrence Handle3528532
MC Wyers ML Schermerhorn MF Fillinger RJ Powell EM Rzucidlo DB Walsh et al. (2002) ArticleTitleInternal iliac occlusion without coil embolization during endovascular abdominal aortic aneurysm repair J Vasc Surg 36 1138–45 Occurrence Handle10.1067/mva.2002.129639 Occurrence Handle12469044
RJ Geraghty LA Sanchez BG Rubin ET Choi MW Flye JA Curci et al. (2004) ArticleTitleOvert ischemic colitis after endovascular repair of aortoiliac aneurysms J Vasc Surg 40 413–8 Occurrence Handle10.1016/j.jvs.2004.05.022 Occurrence Handle15337866
TS Maldonado CB Rockman E Riles D Douglas MA Adelman GR Jacobowitz et al. (2004) ArticleTitleIschemic complications after endovascular abdominal aortic aneurysm repair J Vasc Surg 40 703–10 Occurrence Handle10.1016/j.jvs.2004.07.032 Occurrence Handle15472598
CB Ernst (1983) ArticleTitlePrevention of intestinal ischemia following abdominal aortic reconstruction Surgery 93 102–6 Occurrence Handle1:STN:280:BiyD1MzkvF0%3D Occurrence Handle6849180
N Sugano Y Inoue T Iwai (2003) ArticleTitleEvaluation of buttock claudication with hypogastric artery stump pressure measurement and near infrared spectroscopy after abdominal aortic aneurysm repair Eur J Vasc Endovasc Surg 26 45–51 Occurrence Handle10.1053/ejvs.2002.1870 Occurrence Handle1:STN:280:DC%2BD3s3ptFOjsQ%3D%3D Occurrence Handle12819647
PL Faries N Morrissey JA Burks E Gravereaux MD Kerstein VJ Teodorescu et al. (2001) ArticleTitleInternal iliac artery revascularization as an adjunct to endovascular repair of aortoiliac aneurysms J Vasc Surg 34 892–9 Occurrence Handle10.1067/mva.2001.118085 Occurrence Handle1:STN:280:DC%2BD3MnkvVSjsA%3D%3D Occurrence Handle11700492
TM Bergamini ES Rachel EV Kinney MT Jung HW Kaebnick RA Mitchell (2002) ArticleTitleExternal iliac artery-to-internal iliac artery endograft: a novel approach to preserve pelvic inflow in aortoiliac stent grafting J Vasc Surg 35 120–4 Occurrence Handle11802142
FR Arko WA Lee BB Hill TJ Fogarty CK Zarins (2004) ArticleTitleHypogastric artery bypass to preserve pelvis circulation: improved outcome after endovascular abdominal aortic aneurysm repair J Vasc Surg 39 404–8 Occurrence Handle10.1016/j.jvs.2003.07.012 Occurrence Handle14743144
U Nakamura M Iwase S Nohara H Kanai K Ichikawa M Iida (2003) ArticleTitleUsefulness of brachial-ankle pulse wave velocity measurement: correlation with abdominal aortic calcification Hypertens Res 26 163–7 Occurrence Handle12627877
T Fujiwara S Saitoh S Takagi H Ohnishi J Ohata H Takeuchi et al. (2004) ArticleTitlePrevalence of asymptomatic arteriosclerosis obliterans and its relationship with risk factors in inhabitants of rural communities in Japan: Tanno-Sobetsu study Atherosclerosis 177 83–8 Occurrence Handle10.1016/j.atherosclerosis.2004.05.028 Occurrence Handle1:CAS:528:DC%2BD2cXos1ekt7s%3D Occurrence Handle15488869
Y Koji H Tomiyama H Ichihashi T Nagae N Tanaka K Takazawa et al. (2004) ArticleTitleComparison of ankle-brachial pressure index and pulse wave velocity as markers of the presence of coronary artery disease in subjects with a high risk of atherosclerotic cardiovascular disease Am J Cardiol 94 868–72 Occurrence Handle10.1016/j.amjcard.2004.06.020 Occurrence Handle15464667
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Unno, N., Inuzuka, K., Mitsuoka, H. et al. Automated Bedside Measurement of Penile Blood Flow Using Pulse-Volume Plethysmography. Surg Today 36, 257–261 (2006). https://doi.org/10.1007/s00595-005-3139-8
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/s00595-005-3139-8