Pentax-AWS airway Scope as an alternative for awake flexible fiberoptic intubation of a morbidly obese patient in the semi-sitting position

  • Short Communication
  • Published:
Journal of Anesthesia Aims and scope Submit manuscript

Abstract

For anesthesia induction in a morbidly obese patient with a full stomach, awake flexible fiberoptic bronchoscope (FOB) intubation in the semi-sitting position may be a suitable choice. A new rigid indirect videolaryngoscope, the Pentax-AWS system, has a unique feature of an adjustable built-in monitor and is designed to be used in patients in various positions. However, the efficacy of its use in such situations has not been investigated or reported. We used the Pentax-AWS system for the intubation of a morbidly obese patient (body mass index >50) who was at risk of regurgitation, anticipated difficult intubation, and supine hypotensive syndrome due to inferior vena cava compression by a huge ovarian cyst. The patient was placed in the sitting position during the intubation procedure. The patient’s trachea was intubated with the Pentax-AWS by an anesthesiologist positioned at the patient’s right and facing her. The Pentax-AWS offered easy intubation under good visualization of the glottic aperture as a consequence of its adjustable integrated monitor, in contrast to difficult intubation with other videolaryngoscopes which require an external monitor. This report illustrates that the Pentax-AWS is useful as an alternative for flexible fiberoptic intubation under these circumstances, as a consequence of its adjustable built-in monitor and integrated tube channel.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

References

  1. Uakritdathikarn T, Asampinawat T, Wanasuwannakul T, Yoosamran B. Awake intubation with Airtraq laryngoscope in a morbidly obese patient. J Med Assoc Thai. 2008;91:564–567.

    PubMed  Google Scholar 

  2. Koyama J, Aoyama T, Kusano Y, Seguchi T, Kawagishi K, Iwashita T, Okamoto K, Okudera H, Takasuna H, Hongo K. Description and first clinical application of AirWay Scope for tracheal intubation. J Neurosurg Anesthesiol. 2006;18:247–250.

    Article  PubMed  Google Scholar 

  3. Suzuki A, Nozaki K, Kunisawa T, Takahata O, Henderson JJ, Iwasaki H. Pentax-AWS® (Airway scope) for awake tracheal intubation. J Clin Anesth. 2007;19:642–643.

    Article  PubMed  Google Scholar 

  4. Johnson DM, From AM, Smith RB, From RP, Maktabi MA. Endoscopic study of mechanisms of failure of endotracheal tube advancement into the trachea during awake fiberoptic orotracheal intubation. Anesthesiology. 2005;102:910–914.

    Article  PubMed  Google Scholar 

  5. El-Khatib MF, Husari A, Jamaleddine GW, Ayoub CM, Bou-Khalil P. Changes in resistances of endotracheal tubes with reductions in the cross-sectional area. Eur J Anaesth. 2008;25:275–279.

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

About this article

Cite this article

Suzuki, A., Terao, M., Aizawa, K. et al. Pentax-AWS airway Scope as an alternative for awake flexible fiberoptic intubation of a morbidly obese patient in the semi-sitting position. J Anesth 23, 162–163 (2009). https://doi.org/10.1007/s00540-008-0701-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00540-008-0701-8

Key words

Navigation