Skip to main content
Log in

Comparison of laparoscopic performance in vivo with performance measured in a laparoscopic simulator

  • Published:
Surgical Endoscopy Aims and scope Submit manuscript

Abstract

Background: Laparoscopic skill was measured objectively through a series of seven tasks in an inanimate laparoscopic simulator. Seven analogous skills were tested in an in vivo porcine model. These skills included transferring, cutting, clipping, placement of a ligating loop, mesh placement, and suturing with an intracorporeal and extracorporeal knot. Scoring of each task rewarded precision and speed.

Methods: Twelve PGY3 residents were given a baseline evaluation in the simulator and in the animal model. They were then randomized to either five practice sessions in the simulator (group A) or no practice (group B). Each group was retested in the simulator and in the animal (final test). Scores in vivo were compared by t-test for baseline versus final evaluation for each group. Linear regression analysis was used to correlate in vivo and in vitro scores for each task and for the total score (sum of all scores).

Results: Group A showed significant improvement in performance in vivo for cutting, clipping, mesh placement, and suturing with an intracorporeal and extracorporeal knot, as well as in the total score (p < 0.05). Group B showed significant improvement in suturing with an intracorporeal and extracorporeal knot, and in the total score. The magnitude of improvement from baseline to final evaluation was significantly greater for group A (p < 0.05). There was significant correlation between in vitro and in vivo total scores and the score for each task (p < 0.05) except for placement of the ligating loop and mesh.

Conclusions: Performance in an in vitro laparoscopic simulator correlated significantly with performance in an in vivo animal model. Practice in the simulator resulted in improved performance in vivo.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 26 March 1998/Accepted: 1 July 1999

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Fried, G., Derossis, A., Bothwell, J. et al. Comparison of laparoscopic performance in vivo with performance measured in a laparoscopic simulator. Surg Endosc 13, 1077–1081 (1999). https://doi.org/10.1007/s004649901176