Fracture of a ceramic liner in a total hip arthroplasty with a sandwich cup

  • Orthopaedic Surgery
  • Published:
Archives of Orthopaedic and Trauma Surgery Aims and scope Submit manuscript

Abstract

Alumina ceramic-on-ceramic total hip arthroplasty (THA) has been widely used due to its advantages such as low wear, scratch resistance, wettable surface and relatively low biological reactivity of the wear particles. Nevertheless, this material in THA still persists to be one of the major concerns about the risk of fracture, due to its brittleness. Many authors have reported a fracture of the ceramic head but few reported a fracture of the ceramic acetabular insert. In order to reduce the rigidity of the ceramic-on-ceramic coupling and prevent an impingement between the rim of the ceramic liner and the metal neck of the femoral stem, a modular acetabular component with a sandwich insertion (alumina/polyethylene/titanium) was proposed. We report the fracture of the ceramic acetabular liner of such a ceramic sandwich cup due to a slightly retroverted position of the cup that causes an impingement between the femoral stem and the rim of the insert. The fracture occurred 3 years after the operation without trauma. At revision the entire cup was replaced using a polyethylene liner without inner ceramic liner.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

Similar content being viewed by others

References

  1. Arenas A, Tejero A, Garbayo A, Arias C, Barbadillo J, Lecumberri J (1999) Ceramic femoral head fractures in total hip replacement. Int Orthop 23(6):351–352

    Article  PubMed  CAS  Google Scholar 

  2. Barrack RL, Burak C, Skinner HB (2004) Concerns about ceramics in THA. Clin Orthop Relat Res 429:73–79

    Article  PubMed  Google Scholar 

  3. Diwanji SR, Seon JK, Song EK, Yoon TR (2007) Fracture of the ABC® ceramic liner: a report of three cases. Clin Orthop Relat Res 453:97–102

    Google Scholar 

  4. Ha YC, Kim SY, Kim HJ, Yoo JJ, Koo KH (2007) Ceramic liner fracture after cementless alumina-on-alumina total hip arthroplasty. Clin Orthop Relat Res 458:106–110

    PubMed  Google Scholar 

  5. Hasegawa M, Sudo A, Hirata H, Uchida A (2003) Ceramic acetabular liner fracture in total hip arthroplasty with a ceramic sandwich cup. J Arthroplasty 18(5):658–661

    Article  PubMed  Google Scholar 

  6. Murphy SB, Ecker TM, Tannast M (2006) Two- to 9-year clinical results of alumina ceramic-on-ceramic THA. Clin Orthop 1–6

  7. Pulliam IT, Trousdale RT (1997) Fracture of a ceramic femoral head after a revision operation. A case report. J Bone Joint Surg Am 79A(1):118–121

    Google Scholar 

  8. Toran MM, Cuenca J, Martinez AA, Herrera A, Thomas JV (2006) Fracture of a ceramic femoral head after ceramic-on-ceramic total hip arthroplasty. J Arthroplasty 21(7):1072–1073

    Article  PubMed  Google Scholar 

  9. Walter A (1992) On the material and the tribology of alumina–alumina couplings for hip joint prostheses. Clin Orthop 282:31–46

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Dragos Popescu.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Popescu, D., Gallart, X., Garcia, S. et al. Fracture of a ceramic liner in a total hip arthroplasty with a sandwich cup. Arch Orthop Trauma Surg 128, 783–785 (2008). https://doi.org/10.1007/s00402-007-0536-z

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00402-007-0536-z

Keywords

Navigation