Skip to main content
Log in

Differential value of adenosine myocardial contrast echocardiography and dobutamine stress echocardiography in evaluating functional significance of coronary artery stenosis in a porcine model

  • Original Contribution
  • Published:
Basic Research in Cardiology Aims and scope Submit manuscript

Abstract

Aim Myocardial contrast echocardiography (MCE) during adenosine induced hyperemia is an experimental method that detects flow limiting coronary artery stenosis by visualizing myocardial perfusion defects. Noninvasive detection of flow limiting coronary artery stenosis in clinical routine is a frequent domaine of dobutamine stress echocardiography (DSE) visualizing ischemia related regional wall motion abnormalities. This study investigated the values of adenosine MCE and DSE in the detection of functionally significant coronary artery stenosis in an experimental open chest pig model. Methods A total of 28 proximal LAD stenoses were instrumented in 12 animals. Reduction of coronary blood flow reserve (Δ CFR [%]) was calculated as a marker of functional significance of coronary artery stenosis (mild to moderate stenosis: Δ CRF ≤ 50%; severe stenosis: Δ CFR > 50%). Fractional area shortening (FAS) and wall thickening (WT) were calculated to evaluate regional wall motion. Peak myocardial contrast intensities (PCI) were measured following aortic root injections of Levovist' to detect myocardial perfusion defects. Results As a group, severe stenosis significantly reduced wall motion response to dobutamine (Δ FAS: 12.0 ± 3.0%, vs. 20 ± 3.0% without stenosis, p < 0.05; Δ WT: 2.2 ± 0.9 mm vs. 0.0 ± 0.8 mm without stenosis, p < 0.05) and diminished myocardial opacification during hyperemia (PCI: 59 ± 8 units vs. 143 ± 16 units without stenosis, p < 0.05). Mild to moderate stenosis did not influence wall motion but reduced myocardial opacification (PCI 89 ± 14 units vs. 143 ± 16 units). PCI correlated more closely with alterations in CFR (r = −0.7, p < 0.0001) than did FAS (r = −0.5, p < 0.002) or WT (r = −0.2, p = 0.3). Conclusion Adenosine myocardial contrast echocardiography detects flow limiting coronary artery stenosis and compares favorably to regional wall motion analysis during dobutamine infusion.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 22 May 2000 / Returned for 1. revision: 26 June 2000 / 1. Revision returned: 11 September 2000 / Returned for 2. revision: 11 October 2000 / 2. Revision returned: 21 December 2000 / Accepted: 15 January 2001

Rights and permissions

Reprints and permissions

About this article

Cite this article

Hardt, S., Pekrul, I., Hansen, A. et al. Differential value of adenosine myocardial contrast echocardiography and dobutamine stress echocardiography in evaluating functional significance of coronary artery stenosis in a porcine model. Basic Res Cardiol 96, 415–421 (2001). https://doi.org/10.1007/s003950170050

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s003950170050

Navigation