Skip to main content
Log in

Tomographic and time resolved PIV measurements on a finite cylinder mounted on a flat plate

  • Research Article
  • Published:
Experiments in Fluids Aims and scope Submit manuscript

Abstract

Tomographic and time resolved PIV measurements were performed to examine the 3D flow topology and the flow dynamic above the upper surface of a low-aspect ratio cylinder at Re ≈ 1 ×  105. This generic experiment is of fundamental interest because it represents flow features which are relevant to many applications such as laminar separation bubbles and turbulent reattachment. At Re  ≈ 1 × 105, laminar separation bubbles arise on the side of the cylinder. Furthermore, on the top of the cylinder a separation with reattachment is of major interest. The tomographic PIV measurement, which allows to determine all three velocity components in a volume instantaneously, was applied to examine the flow topology and interaction between the boundary layer and wake structures on the top of the finite cylinder. In the instantaneous flow fields the tip vortices and the recirculation region becomes visible. However, it is also observed that the flow is quite unsteady due to the large separation occurring on the top of the cylinder. In order to study the temporal behaviour of the separation, time resolved PIV was applied. This technique allows capturing the dynamic processes in detail. The development of vortices in the separated shear layer is observed and in addition regions with different dominant frequencies are identified.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 14
Fig. 15
Fig. 16
Fig. 17
Fig. 18
Fig. 19
Fig. 20
Fig. 21
Fig. 22

Similar content being viewed by others

References

  • Elsinga GE, Scarano F, Wieneke B, van Oudheusden BW (2006) Tomographic particle image velocimetry. Exp Fluids 41:933–947

    Article  Google Scholar 

  • Hain R, Kähler CJ, Tropea C (2007) Comparison of CCD, CMOS and intensified cameras. Exp Fluids 42:403–411

    Article  Google Scholar 

  • Hain R, Kähler CJ (2007) Fundamentals of multiframe particle image velocimetry (PIV). Exp Fluids 42:575–587

    Article  Google Scholar 

  • Hain R, Kähler CJ, Michaelis D (2007) Tomographic and time resolved PIV measurements on a finite cylinder mounted on a flat plate. In: Seventh international symposium on particle image velocimetry, Rome, September 11–14

  • Jeong J, Hussain F (1995) On the identification of a vortex. J Fluid Mech 285: 69–94

    Article  MATH  MathSciNet  Google Scholar 

  • Pattenden RJ, Turnock SR, Zhang X (2005) Measurements of the flow over a low-aspect-ratio cylinder mounted on a ground plane. Exp Fluids 39:10–21

    Article  Google Scholar 

  • Roh SC, Park SO (2003) Vortical flow over the free end surface of a finite circular cylinder mounted on a flat plate. Exp Fluids 34:63–67

    Google Scholar 

  • Westerweel J, Scarano F (2005) Universal outlier detection for PIV data. Exp Fluids 39: 1096–1100

    Article  Google Scholar 

  • Wieneke B (2007) Volume Self-Calibration for Stereo-PIV and Tomographic-PIV. 7th International Symposium on Particle Image Velocimetry, Rome, September 11–14

Download references

Acknowledgments

The authors acknowledge the support by PCO for providing two PCO pco.4000 cameras for the tomographic PIV measurements. This research has been supported by the German Research Foundation (DFG) in the priority program 1147 "Bildgebende Messverfahren für die Strömungsanalyse".

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Christian J. Kähler.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Hain, R., Kähler, C.J. & Michaelis, D. Tomographic and time resolved PIV measurements on a finite cylinder mounted on a flat plate. Exp Fluids 45, 715–724 (2008). https://doi.org/10.1007/s00348-008-0553-x

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00348-008-0553-x

Keywords

Navigation