This study compared simultaneous intravesical pressure readings obtained with catheter-mounted microtip transducers and external water pressure transducer catheters during filling cystometry. Women undergoing multichannel urodynamic testing were randomly assigned to one of three groups: two microtip catheters, two external water pressure transducer catheters, or one of each type. Intravesical pressure was measured simultaneously for each transducer combination in each subject for minimal and maximal Valsalva effort and minimal, moderate, and maximal cough effort at two sequential bladder volumes (150 and 300 ml). Paired t tests were used to compare the means of the intravesical pressure obtained by the two types of catheters. The largest mean differences were observed when comparing microtip and water pressure transducers. Correlations of maximum pressure were consistently high between two microtip transducers and two water pressure transducers but lower for the microtip–water combination. Excellent reproducibility was demonstrated with transducers of similar types for intravesical pressures recorded during Valsalva and cough in women without prolapse. However, considerable variability was seen in pressures recorded by different transducers, particularly dependent on the water catheter manufacturer, indicating that intravesical pressure recordings from microtip and water-based systems are not interchangeable.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Abrams P, Cardozo L, Fall M et al (2002) The standardisation of terminology of lower urinary tract function: report from the Standardisation Sub-committee of the International Continence Society. Am J Obstet Gynecol 187:116–126

    Article  PubMed  Google Scholar 

  2. Bump RC, Elser DM, Theofrastous JP, McClish DK (1995) Valsalva leak point pressures in women with genuine stress incontinence: reproducibility, effect of catheter caliber, and correlations with other measures of urethral resistance. Continence Program for Women Research Group. Am J Obstet Gynecol 173:551–557

    Article  PubMed  CAS  Google Scholar 

  3. Swift SE, Utrie JW (1996) The need for standardization of the Valsalva leak-point pressure. Int Urogynecol J Pelvic Floor Dysfunct 7:227–230

    Article  PubMed  CAS  Google Scholar 

  4. Swift SE, Yoon EA (1999) Test–retest reliability of the cough stress test in the evaluation of urinary incontinence. Obstet Gynecol 94:99–102

    Article  PubMed  CAS  Google Scholar 

  5. Miklos JR, Sze EH, Karram MM (1995) A critical appraisal of the methods of measuring leak-point pressures in women with stress incontinence. Obstet Gynecol 86:349–352

    Article  PubMed  CAS  Google Scholar 

  6. Wang AC, Chen MC (2002) A comparison of urethral pressure profilometry using microtip and double-lumen perfusion catheters in women with genuine stress incontinence. BJOG 109:322–326

    Article  PubMed  Google Scholar 

  7. Hundley AF, Visco AG (2004) Comparison of measurements obtained with microtip and external water pressure transducers. Int Urogynecol J Pelvic Floor Dysfunct 15:276–280

    PubMed  Google Scholar 

  8. Rowan D, James ED, Kramer AE, Sterling AM, Suhel PF (1987) Urodynamic equipment: technical aspects. Produced by the International Continence Society Working Party on Urodynamic Equipment. J Med Eng Technol 11:57–64

    Article  PubMed  CAS  Google Scholar 

Download references

Acknowledgements

The authors would like to thank Robert Park, Chairman of the Steering Committee for the PFDN.

This work was supported by grants from the National Institute of Child Health and Human Development (U01 HD41249, U10 HD41268, U10 HD41248, U10 HD41250, U10 HD41261, U10 HD41263, U10 HD41269, and U10 HD41267).

Author information

Authors and Affiliations

Authors

Additional information

Abstract presented at the International Continence Society Annual Meeting, Paris, France, August, 2004

Rights and permissions

Reprints and permissions

About this article

Cite this article

Hundley, A.F., Brown, M.B., Brubaker, L. et al. A multicentered comparison of measurements obtained with microtip and external water pressure transducers. Int Urogynecol J 17, 400–406 (2006). https://doi.org/10.1007/s00192-005-0027-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00192-005-0027-0

Keywords

Navigation