Skip to main content
Log in

The reliability of isokinetic testing of the ankle joint and a heel-raise test for endurance

  • Sports Medicine
  • Published:
Knee Surgery, Sports Traumatology, Arthroscopy Aims and scope

Abstract

The aim of the present study was to investigate the reliability of different methods used for isokinetic testing of calf muscle strength and endurance. The detailed evaluation of test-retest reliability serves the purpose of establishing reliable research tools when evaluating patients who have sustained an Achilles tendon rupture. The test-retest reliability of isokinetic measurements at the ankle for eccentric and concentric muscle action was calculated in ten healthy male volunteers using intra-class correlation (ICC) and coefficient of variation (CV). Three different positions were compared at the angular velocities of 30°/s and 180°/s for right and left ankles. The ICC for plantar flexion was 0.37–0.95, whilst it was 0.00–0.96 for dorsiflexion. The corresponding CVs were 4.0–19.9 and 2.4–19.8 respectively. The test-retest reliability of standardised heel-raises, Achilles tendon width, calf circumference and ankle range of motion revealed ICC values of 0.71–0.98 and CVs of 0.67–19.1. The test-retest interval was 5 to 7 days. We conclude that all three positions studied for the isokinetic evaluation of calf muscle function are equally reliable concerning plantar flexion at the ankle joint. The same level of reliability was also found in the evaluation of the standing heel-raise test and the isokinetic dorsiflexion test, except for dorsiflexion in the supine position. The reliability of the investigated methods was only fair despite the use of a detailed and standardised test protocol.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6

Similar content being viewed by others

References

  1. Alexander MJ (1990) Peak torque values for antagonist muscle groups and concentric and eccentric contraction types for elite sprinters. Arch Phys Med Rehabil 71:334–339

    CAS  PubMed  Google Scholar 

  2. Andersen H (1996) Reliability of isokinetic measurements of ankle dorsal and plantar flexors in normal subjects and in patients with peripheral neuropathy. Arch Phys Med Rehabil 77:265–268

    CAS  PubMed  Google Scholar 

  3. Balogun J, Onigbinde A (1992) Hand and leg dominance: do they really affect limb muscle strength? Physiother Theory Pract 8:89–96

    Google Scholar 

  4. Bland J, Altman D (1986) Statistical methods for assessing agreement between two methods of clinical measurements. Lancet 1:307–310

    CAS  PubMed  Google Scholar 

  5. Bland J, Altman D (1996) Measurement error. BMJ 313:744

    CAS  PubMed  Google Scholar 

  6. Bobbert MF, van Ingen Schenau GJ (1990) Mechanical output about the ankle joint in isokinetic plantar flexion and jumping. Med Sci Sports Exerc 22:660–668

    CAS  PubMed  Google Scholar 

  7. Calmels PM, Nellen M, van der Borne I, Jourdin P, Minaire P (1997) Concentric and eccentric isokinetic assessment of flexor-extensor torque ratios at the hip, knee, and ankle in a sample population of healthy subjects. Arch Phys Med Rehabil 78:1224–1230

    CAS  PubMed  Google Scholar 

  8. Capranica L, Battenti M, Demarie S, Figura F (1998) Reliability of isokinetic knee extension and flexion strength testing in elderly women. J Sports Med Phys Fitness 38:169–176

    CAS  PubMed  Google Scholar 

  9. Cox PD (1995) Isokinetic strength testing of the ankle: a review. Physiother Can 47:97–106

    Google Scholar 

  10. Daube JR, Sandok RA, Reagan TJ, Westmorland BF (1978) In: Brown L (ed) Medical Neuroscience, Boston, pp 379–382

  11. Dvir Z (1995) Isokinetics of the ankle muscles. In: Dvir Z, Isokinetics; muscle testing, interpretation and clinical applications. Churchill-Livingstone, Edinburgh, pp 129–143

  12. Fugl-Meyer AR, Sjöström M, Wahlby L (1979) Human plantar flexion strength and structure. Acta Physiol Scand 107:47–56

    CAS  PubMed  Google Scholar 

  13. Fugl-Meyer AR, Gustafsson L, Burstedt Y (1980) Isokinetic and static plantar flexion characteristics. Eur J Appl Physiol 45:221–234

    Google Scholar 

  14. Good P (2000) Permutation tests. A practical guide to resampling methods for testing hypotheses. Springer, Berlin Heidelberg New York

  15. Häggmark T, Liedberg H, Eriksson E, Wredmark T (1986) Calf muscle atrophy and muscle function after non-operative vs operative treatment of Achilles-tendon ruptures. Orthopedics 9:160–164

    PubMed  Google Scholar 

  16. Holmbäck AM, Porter MM, Downham D, Lexell J (1999) Reliability of isokinetic ankle dorsiflexor strength measurements in healthy young men and women. Scand J Rehabil Med 31:229–239

    PubMed  Google Scholar 

  17. Karnofel H, Wilkinson K, Lentell G (1989) Reliability of isokinetic muscle testing at the ankle. J Orthop Sports Phys Ther 11:150–154

    Google Scholar 

  18. Kawakami Y, Sale DG, MacDougall JD, Moroz JS (1998) Bilateral deficit in plantar flexion: relation to knee joint position, muscle activation, and reflex excitability. Eur J Appl Physiol 77:212–216

    CAS  Google Scholar 

  19. Keating JL, Matyas TA (1996) The influence of subject and test design on dynamometric measurements of extremity muscles. Phys Ther 76:866–889

    CAS  PubMed  Google Scholar 

  20. Komi P (1979) Neuromuscular performance: factors influencing force and speed production. Scand J Sports Sci 1:2–15

    Google Scholar 

  21. Li RC, Maffulli N, Hsu YC, Chan KM (1996) Isokinetic strength of the quadriceps and hamstrings and functional ability of anterior cruciate deficient knees in recreational athletes. Br J Sports Med 30:161–164

    CAS  PubMed  Google Scholar 

  22. Lunsford BR, Perry J (1995) The standing heel-rise test for ankle plantar flexion: criterion for normal. Phys Ther 75:694–698

    CAS  PubMed  Google Scholar 

  23. Maupas E, Paysant J, Martinet N, Andre J (1999) Asymmetric leg activity in healthy subjects during walking, detected by electro goniometry. Clin Biomech 14:403–411

    CAS  Google Scholar 

  24. Mayhew TP, Rothstein JM, Finucane SDG, Lamb RL (1994) Performance characteristics of the Kin-Com dynamometer. Phys Ther 74:1047–1054

    CAS  PubMed  Google Scholar 

  25. Miaki H, Someya F, Tachino K (1999) A comparison of electrical activity in the triceps surae at maximum isometric contraction with the knee and ankle at various angles. Eur J Appl Physiol 80:185–191

    Google Scholar 

  26. Morris-Chatta R, Buchner DM, de Lateur BJ, Cress ME, Wagner EH (1994) Isokinetic testing of ankle strength in older adults: assessment of inter-rater reliability and stability of strength over six months. Arch Phys Med Rehabil 75:1213–1216

    CAS  PubMed  Google Scholar 

  27. Möller M, Lind K, Styf J, Karlsson J (2000) The test-retest reliability of concentric and eccentric muscle action during plantar flexion of the ankle joint in a closed kinetic chain. Isokinet Exerc Sci 8:223–228

    Google Scholar 

  28. Möller M, Movin T, Granhed H, Lind K, Faxén E, Karlsson J (2001) Acute rupture of tendon Achilles. A prospective randomised study of comparison between surgical and non-surgical treatment. J Bone Joint Surg Br 83:843–848

    PubMed  Google Scholar 

  29. Möller M, Lind K, Movin T, Karlsson J (2002) Calf muscle function after Achilles tendon rupture. A prospective, randomised study comparing surgical and non-surgical treatment. Scand J Med Sci Sports 12:9–16

    PubMed  Google Scholar 

  30. Öberg B, Bergman T, Tropp H (1987) Testing of isokinetic muscle strength in the ankle. Med Sci Sports Exerc 19:318–322

    PubMed  Google Scholar 

  31. Porter MM, Vandervoort AA, Kramer JF (1996) A method of measuring standing isokinetic plantar and dorsiflexion peak torques. Med Sci Sports Exerc 28:516–522

    CAS  PubMed  Google Scholar 

  32. Scranton PE Jr, Whitesel JP, Farewell V (1985) Cybex evaluation of the relationship between anterior and posterior compartment lower leg muscles. Foot Ankle 6:85–89

    PubMed  Google Scholar 

  33. Sepic S, Murray P, Mollinger L, Spurr G, Gardner G (1986) Strength and range of motion in the ankle in two age groups of men and women. Am J Phys Med 65:75–84

    CAS  PubMed  Google Scholar 

  34. Seymor R, Bacharach D (1990) The effect of position and speed on ankle plantar flexion in females. J Orthop Sports Phys Ther 12:153–156

    Google Scholar 

  35. Shrout PE, Fleiss JL (1979) Intraclass correlations: uses in assessing rater reliability. Psychol Bull 86:420–428

    Article  Google Scholar 

  36. Steiner LA, Harris BA, Krebs DE (1993) Reliability of eccentric isokinetic knee flexion and extension measurements. Arch Phys Med Rehabil 7:1327–1335

    Google Scholar 

  37. Svantesson U, Ernstoff B, Bergh P, Grimby G (1991) Use of a Kin-Com dynamometer to study the stretch-shortening cycle under plantar flexion. Eur J Appl Physiol 62:415–419

    CAS  Google Scholar 

  38. Svantesson U, Grimby G, Thomeé R (1994) Potentiation of concentric plantar flexion torque following eccentric and isometric muscle actions. Acta Physiol Scand 152:287–293

    CAS  PubMed  Google Scholar 

  39. Svantesson U, Österberg U, Grimby G, Sunnerhagen KS (1998) The standing heel-rise test in patients with upper motor neuron lesion due to stroke. Scand J Rehabil Med 30:73–80

    CAS  PubMed  Google Scholar 

  40. Wennerberg D (1991) Reliability of an isokinetic dorsiflexion and plantar flexion apparatus. Am J Sports Med 19:519–522

    CAS  PubMed  Google Scholar 

  41. Woodson C, Bandy WD, Curis D, Baldwin D (1995) Relationship of isokinetic peak torque with work and power for ankle plantar flexion and dorsiflexion. J Orthop Sports Phys Ther 22:113–115

    CAS  PubMed  Google Scholar 

Download references

Acknowledgements

Financial support was provided by the Swedish Sports Research Council, the Göteborg Medical Society, LUA-grant Göteborg University. For statistical advice, we acknowledge Henrik Ahlbom and Nils-Gunnar Pehrsson, Göteborg. The study was approved by the Human Research Ethics Committee at the Faculty of Medicine, Göteborg University.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Michael Möller.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Möller, M., Lind, K., Styf, J. et al. The reliability of isokinetic testing of the ankle joint and a heel-raise test for endurance. Knee Surg Sports Traumatol Arthrosc 13, 60–71 (2005). https://doi.org/10.1007/s00167-003-0441-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00167-003-0441-0

Keywords

Navigation