Summary
A miniaturized amperometric, enzymatic, glucose sensor (outer diameter 0.45 mm) was evaluated after implantation in the subcutaneous tissue of normal rats. A simple experimental procedure was designed for the long-term assessment of the sensor's function which was performed by recording the current during an intraperitoneal glucose load. The sensor was calibrated by accounting for the increase in the current during the concomitant increase in plasma glucose concentration, determined in blood sampled at the tail vein. This made it possible to estimate the glucose concentration in subcutaneous tissue. During the glucose load, the change in subcutaneous glucose concentration followed that in blood with a lag time consistently shorter than 5 min. The estimations of subcutaneous glucose concentration during these tests were compared to the concomitant plasma glucose concentrations by using a grid analysis. Three days after implantation (n=6 experiments), 79 estimations were considered accurate, except for five which were in the acceptable zone. Ten days after implantation (n=5 experiments), 101 estimations were accurate, except for one value, which was still acceptable. The sensitivity was around 0.5 nA mmol−1·l−1 on day 3 and day 10. A longitudinal study on seven sensors tested on different days demonstrated a relative stability of the sensor's sensitivity. Finally, histological examination of the zone around the implantation site revealed a fibrotic reaction containing neocapillaries, which could explain the fast response of the sensor to glucose observed in vivo, even on day 10. We conclude that this miniaturized glucose sensor, whose size makes it easily implanted, works for at least ten days after implantation into rat subcutaneous tissue.
Article PDF
Similar content being viewed by others
References
Pickup JC (1985) Biosensors: a clinical perspective. Lancet II:817–820
Armour JC, Lucisano JY, McKean BD, Gough D (1990) Application of chronic intravascular blood glucose sensor in dogs. Diabetes 39: 1519–1526
Shichiri M, Yamasaki Y, Kawamori R, Hakui N, Abe H (1982) Wearable artificial endocrine pancreas with needle-type glucose sensor. Lancet II: 1129–1131
Abel P, Müller A, Fischer U (1984) Experience with an implantable glucose sensor as a prerequisite of an artificial beta cell. Biomed Bioch Acta 43: 577–588
Matthews DER, Bown E, Beck TW et al. (1988) An amperometric needle-type glucose sensor tested in rats and man. Diab Med 5: 248–252
Pickup JC, Shaw GW, Claremont DJ (1989) In vivo molecular sensing in diabetes mellitus: an implantable glucose sensor with direct electron transfer. Diabetologia 32: 213–217
Claremont DJ, Sambrook IE, Penton C, Pickup JC (1986) Subcutaneous implantation of a ferrocenemediated glucose sensor in pigs. Diabetologia 29: 817–821
Kerner W, Bruekel J, Zier H et al. (1989) Glucose measurement in subcutaneous tissue. Artificial Organs 13: 173 (Abstract)
Velho GD, Reach G, Thévenot D (1987) The design and development of in vivo glucose sensors for artifical endocrine pancreas. In: Turner APF, Karube I, Wilson GS (eds) Biosensors: fundamentals and applications. Elsevier, Barking, pp 390–408
Koudelka M, Rohner-Jeanrenaud F, Terrettaz J, Bobbioni-Harsch E, de Rooij NF, Jeanrenaud B (1991) In-vivo behaviour of hypodermically implanted microfabricated glucose sensors. Biosensor Bioelectronics 6: 31–36
Ege H (1989) A needle-shaped glucose sensor using an aquaeous Polyurethane dispersion for membrane formation and for immobilization of glucose oxidase. Artificial Organs 13: 171 (Abstract)
Fischer U, Ertle R, Abel P, Rebrin K, Brunstein E, Hahn von Dorsche H, Freyse EJ (1987) Assessment of subcutaneous glucose concentration: validation of the wick technique as a reference for implanted electrochemical sensors in normal and diabetic dogs. Diabetologia 30: 940–945
Rebrin K, Fischer U, Woedtke TV, Abel P, Brunstein E (1989) Automated feedback control of subcutaneous glucose concentration in diabetic dogs. Diabetologia 32: 573–576
Bindra DS, Zhang Y, Wilson G et al. (1991) Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring. Anal Chem 63: 1692–1696
Velho G, Froguel P, Thévenot DR, Reach G (1989) Strategies for calibrating a subcutaneous glucose sensor. Biomed Biochem Acta 48: 957–964
Clarke WL, Cox D, Gonder-Frederick LA, Carter W, Pohl SL (1987) Evaluating clinical accuracy of systems for self-monitoring of blood glucose. Diab Care 5: 622–627
Fischer U, Abel P, Rebrin K, Hahn von Dorsche H, Brunstein E (1990) Rôle et possibilités des techniques actuelles de la détermination intracorporelle de la glycémic dans le traitement du diabète insulino-dépendant. Flammarion Médecine-Sciences, Journées de Diabétologie Hôtel-Dieu 1990: 247–366
Shichiri M, Kawamori R, Goriya Y, Yamasaki Y, Nomura M, Hakui N, Abe H (1983) Glycaemic control in pancreatectomized dogs with a wearable artificial endocrine pancreas. Diabetologia 24: 179–184
Rebrin K, Hahn von Dorsche H (1989) Subcutaneous implanted glucose sensors as a part of the artificial β-cell. Artificial Organs 13: 174 (Abstract)
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Moatti-Sirat, D., Capron, F., Poitout, V. et al. Towards continuous glucose monitoring: in vivo evaluation of a miniaturized glucose sensor implanted for several days in rat subcutaneous tissue. Diabetologia 35, 224–230 (1992). https://doi.org/10.1007/BF00400921
Received:
Revised:
Issue Date:
DOI: https://doi.org/10.1007/BF00400921