Summary
Miniature, amperometric glucose sensors were constructed for implantation in the subcutaneous tissue of normal and insulin-dependent diabetic subjects. To minimise dependence on fluctuating tissue oxygen tension, we employed the technology of mediated electron transfer, with 1,1′-dimethylferrocene acting as the redox shuttle between immobilized glucose oxidase and a platinum base electrode. In 6 normal subjects, the subcutaneous sensor responses mirrored the simultaneously-measured changes in blood glucose concentration after a 75 g oral glucose load and after intravenous injection of 0.15 U/kg short-acting insulin, though increases and decreases in the sensor output were slower than the glycaemic changes. The mean peak delay in sensor response after the oral glucose was 40 min (range 0–45 min) and the delay in the hypoglycaemic nadir was 4 min (range 0–15 min). In 5 insulin-dependent diabetic subjects, spontaneous and induced hypoglycaemia was detectable by the implanted sensor. In addition, marked and frequent oscillations in the sensor current occurred in several normal and diabetic individuals as the blood glucose fell below about 1.9 mmol/l. These oscillations were present in a diabetic subject who had lost adrenergic warning symptoms to hypoglycaemia. Continuous metabolic monitoring in diabetes, particularly the detection of hypoglycaemia, may be possible with implanted sensors based on this technology.
Article PDF
Similar content being viewed by others
References
Pickup JC (1985) Biosensors: a clinical perspective. Lancet II: 817–820
Anon (1987) Awareness of hypoglycaemia in diabetes. Lancet II: 371–372
Claremont DJ, Sambrook IE, Penton C, Pickup JC (1986) Subcutaneous implantation of a ferrocene-mediated glucose sensor in pigs. Diabetologia 29: 817–821
Pickup JC, Shaw GW, Claremont DJ (1989) Potentially-implantable amperometric glucose sensors with mediated electron transfer: improving the operating stability. Biosensors in press
Claremont DJ, Shaw GW, Pickup JC (1988) Improving the stability of potentially-implantable glucose sensors. Diabetic Med 5 [Suppl.]: 2A
Cass AEG, Davis G, Francis GD, Hill HAO, Aston WJ, Higgins IJ, Plotkin EV, Scott LDL, Turner APF (1984) Ferrocene-mediated enzyme electrode for amperometric determination of glucose. Anal Chem 56: 667–671
Matthews DR, Bown E, Beck TW, Plotkin E, Lock L, Gosden E, Wickham M (1988) An amperometric needle-type glucose sensor tested in rats and man. Diabetic Med 5: 248–252
Bessman SP, Thomas LJ, Kojiima H, Sayler DF, Layne EC (1981) The implantation of a closed-loop artifical beta cell in dogs. Trans Am Soc Art Int Org 27: 7–17
Abel P, Miller A, Fischer U (1984) Experience with an implantable glucose sensor as a prerequisite of an artificial beta cell. Biomed Biochim Acta 5: 577–584
Shichiri M, Kawamori R (1983) Feasibility of a needle-type glucose sensor and the wearable artifical endocrine pancreas system in human diabetic subjects. In: Irsigler K, Kritz, Lovett R (eds) Diabetes treatment with implantable insulin infusion systems, Urban & Schwarzenberg, Munich, pp 224–230
Fischer U, Ertle R, Abel P, Rebrin K, Brunstein E, Hahn von Dorsche H, Freyse EJ (1987) Assessment of subcutaneous glucose concentration: validation of the wick technique as a reference for implanted electrochemical sensors in normal and diabetic dogs. Diabetologia 30: 940–945
Velho G, Froguel P, Reach G, Thevenot D (1987) In vivo calibration of a needle-type glucose sensor to determine the kinetics of subcutaneous glucose concentration. Diabetologia 30: 592 A
Rebrin K, Fischer U, Woedtke TV, Brunstein E, Abel P (1988) Tissue glucose telemetry and control in normal and diabetic dogs. Diabetologia 31: 534 A
D'Costa EJ, Higgins IJ, Turner APF (1986) Quinoprotein glucose dehydrogenase and its application in an amperometric glucose sensor. Biosensors 2: 71–87
Kulys JJ (1986) Enzyme electrodes based on organic metals Biosensors 2: 3–13
Albery WJ, Bartlett PN, Craston DH (1985) Amperometric enzyme electrodes II. Conducting salts as electrode materials for the oxidation of glucose oxidase. J Electroanal Chem 194: 223–235
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Pickup, J.C., Shaw, G.W. & Claremont, D.J. In vivo molecular sensing in diabetes mellitus: an implantable glucose sensor with direct electron transfer. Diabetologia 32, 213–217 (1989). https://doi.org/10.1007/BF00265097
Received:
Revised:
Issue Date:
DOI: https://doi.org/10.1007/BF00265097