Skip to main content
Log in

Potentiometric sensors based on new active components in the multisensor determination of homologues anionic surfactants

  • Articles
  • Published:
Journal of Analytical Chemistry Aims and scope Submit manuscript

Abstract

Potentiometric sensors are proposed on the basis of alkyl sulfates and cationic copper(II) complexes with organic reagents selective to anionic surfactants. Physical and chemical properties of the ionophores (composition, thermal stability, solubility) are determined in aqueous solutions and in the membrane phase. The studied compounds are poorly soluble (K s = n × 10–22n × 10–20) and thermally stable at 80−90°C. The main electroanalytical properties of sensors are estimated, i.e., analytical range in solutions of sodium alkyl sulfates 2 × 10–7–1 × 10–2 M; 46 <α < 66 mV/рc; LOD = 1 × 10–7 M; response time 8–9 s in a solution of sodium dodecyl sulfate with the concentration not lower than 1 × 10–4 M; potential drift 2–3 mV/day; and lifetime 12 months. The multisensor determination of homologues sodium alkyl sulfates in model mixtures and natural waters is performed using the proposed sensors.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Najafi, M., Maleki, L., and Rafati, A., J. Mol. Liq., 2011, vol. 159, no. 3, p. 226.

    Article  CAS  Google Scholar 

  2. Stepanets, O.V., Solov’eva, G.Yu., Mikhailova, A.M., and Kulapin, A.I., J. Anal. Chem., 2001, vol. 56, no. 3, p. 290.

    Article  Google Scholar 

  3. Segui, M.J., Lizondo-Sabater, J., Benito, A., Martinez-Manez, R., Pardo, T., Sancenon, F., and Soto, J., Talanta, 2007, vol. 71, no. 1, p. 333.

    Article  CAS  Google Scholar 

  4. Kulapina, E.G. and Ovchinskii, V.A., J. Anal. Chem., 2000, vol. 55, no. 2, p. 169.

    Article  CAS  Google Scholar 

  5. Martinez-Barrachina, S. and del Valle, M., Microchem. J., 2006, vol. 83, no. 1, p. 48.

    Article  CAS  Google Scholar 

  6. Kulapina, E.G., Chernova, R.K., and Kulapin, A.I., Potentsiometricheskie sensory dlya opredeleniya sinteticheskikh poverkhnostno-aktivnykh veshchestv (Potentiometric Sensors for Determining Synthetic Surfactants), Saratov: Nauchnaya Kniga, 2008.

    Google Scholar 

  7. Kulapina, E.G. and Mikhaleva, N.M., Sens. Actuators B, 2005, vol. 106, no. 1, p. 271.

    Article  CAS  Google Scholar 

  8. Kulapina, E.G., Mikhaleva, N.M., and Shmakov, S.L., J. Anal. Chem., 2004, vol. 59, no. 5, p. 487.

    Article  CAS  Google Scholar 

  9. Mikhaleva, N.M., Kulapina, E.G., Kolotvin, A.A., and Lobachev, A.L., J. Anal. Chem., 2007, vol. 62, no. 11, p.1088.

    Article  CAS  Google Scholar 

  10. Lizondo-Sabater, J., Martínez-Máñez, R., Sancenón, F., Seguí, M.J., and Soto, J., Talanta, 2008, vol. 75, no. 1, p. 317.

    Article  CAS  Google Scholar 

  11. Matesic-Puac, R., Sak-Bosnar, M., Bilic, M., and Grabaric, B.S., Sens. Actuators B, 2005, vol. 106, no. 1, p. 221.

    Article  CAS  Google Scholar 

  12. Seguí, MJ., Lizondo-Sabater, J., Martínez-Máñez, R., Pardo, T., Sancenón, F., and Soto, J., Anal. Chim. Acta, 2004, vol. 525, no. 1, p. 83.

    Article  Google Scholar 

  13. Orlova, A.O., Lizunova, G.M., and Zorin, A.D., Analitika Kontrol’, 2004, vol. 8, no. 2, p. 131.

    Google Scholar 

  14. Cortina, M., Ecker, Ch., Calvo, D., and del Valle, M., J. Pharm. Biomed. Anal., 2008, vol. 46, no. 2, p. 213.

    Article  CAS  Google Scholar 

  15. Chernyshov, D.V., Khrenova, M.G., Pletnev, I.V., and Shvedene, N.V., Mendeleev Commun., 2008, vol. 18, no. 2, p. 88.

    Article  CAS  Google Scholar 

  16. Shvedene, N.V., Chernyshov, D.V., Khrenova, M.G., Formanovsky, A.A., Baulin, V.E., and Pletnev, I.V., Electroanalysis, 2006, vol. 18, nos. 13–14, p. 1416.

    Article  CAS  Google Scholar 

  17. Inyaev, I.V., Krupnova, T.G., Golovanov, V.I., Vestn. ChelyabinskUniv., Ser. 4, 2001, no. 1, p. 28.

    Google Scholar 

  18. Shchipunov, Yu.A. and Shchumilina, E.V., J. Anal. Chem., 1996, vol. 51, no. 7, p. 698.

    CAS  Google Scholar 

  19. Legin, A., Vlasov, Yu., Rudnitskaya, A., and Bychkov, E., Sens. Actuators B, 1996, vol. 34, nos. 1–3, p. 456.

    Article  CAS  Google Scholar 

  20. Mirsaizyanova, S.A., Ziyatdinova, A.B., and Amirov, R.R., Colloid J., 2011, vol. 73, no. 4, p. 509.

    Article  CAS  Google Scholar 

  21. Mamedova, L.N., Mamedov, G.M., Agaguseinova, M.M., Serikbaeva, A.K., and Dzhumasheva, K.A., Vestn. Kaz. Natl. Univ., Ser. Khim., 2012, no. 4(68), p. 195.

    Article  Google Scholar 

  22. Bychkovskaya, G.I. and Roeva, N.N., Sorbtsionnye Khromatogr. Protsessy, 2008, vol. 8, no. 3, p. 487.

    Google Scholar 

  23. Sasikala, K. and Arunachalam, S., J. Chem. Biol. Phys. Sci., 2012, vol. 2, no. 2, p. 708.

    CAS  Google Scholar 

  24. Abd-Elzaher, M.M., Synth. React. Inorg. Met.-Org. Chem., 2000, vol. 30, no. 9, p. 1805.

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to N. M. Makarova.

Additional information

Original Russian Text © N.M. Makarova, E.G. Kulapina, 2017, published in Zhurnal Analiticheskoi Khimii, 2017, Vol. 72, No. 4, pp. 369–377.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Makarova, N.M., Kulapina, E.G. Potentiometric sensors based on new active components in the multisensor determination of homologues anionic surfactants. J Anal Chem 72, 421–429 (2017). https://doi.org/10.1134/S1061934817040074

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S1061934817040074

Keywords

Navigation