Skip to main content
Log in

A comparison of electrospray tandem mass spectra of some sialic acid derivatives: Ion trap and high resolution QqToF mass spectrometers

  • Articles
  • Published:
Journal of Analytical Chemistry Aims and scope Submit manuscript

Abstract

Using O-acetyl-N-acyl derivatives of O-methyl sialoside methyl esters, it was shown that an ion trap and a hybrid analyzer (linear quadrupole–time-of-flight analyzer, reflectron) give comparable, though not identical secondary mass spectra for the [M + Na]+ and [M + K]+ ions. A parallel use of an ion trap and a hybrid QqToF instrument gives information about the fragmentation pathways of ions of sialic acid derivatives under collisional activation. In this case, the sequence of fragmentation may be established using an ion trap, whereas a QqToF instrument offers a possibility of revealing the elemental composition of fragment ions quickly and unequivocally.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Schauer, R., Biochemistry of sialic acid diversity, in Carbohydrates in Chemistry and Biology, Ernst, B., Hart, G.W., and Sinay, P., Eds., Weinheim: Wiley, 2000, ch. 52, p. 227.

    Chapter  Google Scholar 

  2. De Gregorio, E. and Rappuoli, R., Nat. Rev. Immunol., 2014, vol. 14, no. 7, p. 505.

    Article  Google Scholar 

  3. Thirumurugan, P., Matosiuk, D., and Jozwiak, K., Chem. Rev., 2013, vol. 113, no. 7, p. 4905.

    Article  CAS  Google Scholar 

  4. Kulikova, N.Yu., Graduat. Pap., Moscow: Higher Chem. College, Russ. Acad. Sci., 2009.

    Google Scholar 

  5. Kadentsev, V.I., Chizhov, A.O., Chizhov, O.S., and Voznyi, Ya.V., Mass-Spektrom., 2008, vol. 5, no. 1, p. 45.

    CAS  Google Scholar 

  6. Tsedilin, A.M., Fakhrutdinov, A.N., Eremin, D.B., Zalesskiy, S.S., Chizhov, A.O., Kolotyrkina, N.G., and Ananikov, V.P., Mendeleev Commun., 2015, vol. 25, no. 11, p. 454.

    Article  CAS  Google Scholar 

  7. Teesch, L.M. and Adams, J., Org. Mass Spectrom., 1992, vol. 27, no. 9, p. 931.

    Article  CAS  Google Scholar 

  8. Chizhov, A.O., Podval’nyi, N.M., Zinin, A.I., Malysheva, N.N., and Kononov, L.O., Mass-Spektrom., 2015, vol. 12, no. 1, p. 55.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to A. O. Chizhov.

Additional information

Original Russian Text © A.O. Chizhov, A.M. Shpirt, N.Y. Savel’eva, L.O. Kononov, 2016, published in Mass-spektrometriya, 2016, Vol. 13, No. 2, pp. 139–143.

The article was translated by the authors.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Chizhov, A.O., Shpirt, A.M., Savel’eva, N.Y. et al. A comparison of electrospray tandem mass spectra of some sialic acid derivatives: Ion trap and high resolution QqToF mass spectrometers. J Anal Chem 71, 1392–1396 (2016). https://doi.org/10.1134/S1061934816140045

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S1061934816140045

Keywords

Navigation