Abstract
The results of experimental studies of a coaxial chopping gap filled with air at atmospheric pressure are presented. At a pulse rise time of 100–300 ps and a voltage pulse amplitude of 30–145 kV, the obtained duration of the voltage-pulse decay time is ≤ 100 ps. The high stability of the gap operation is attained in the presence of the edge with a small radius of curvature on one of the electrodes. The fast voltage decay across the gap is determined by the preionization of the gap by runaway electrons.
Similar content being viewed by others
References
Mesyats, G.A., Impul’snaya energetika i elektronika (Pulsed Power Engineering and Electronics), Moscow: Nauka, 2004.
Yalandin, M.I. and Shpak, V.G., Prib. Tekh. Eksp., 2001, no. 3, p. 5.
Ivanov, S.N., Lisenkov, V.V., and Shpak, V.G., Zh. Tekh. Fiz., 2008, vol. 78, no. 9, p. 62 [Tech. Phys. (Engl. Transl.), vol. 78, no. 9, p. 1162].
Krompholz, H.G., Hatfield, L.L., Neuber, A.A., et al., IEEE Trans. Plasma Science, 2006, vol. 34, no. 3, p. 927.
Kostyrya, I.D., Tarasenko, V.F., and Shitts, D.V., Prib. Tekh. Eksp., 2008, no. 4, p. 159 [Instr. Exp. Techn. (Engl. Transl.), vol. 51, no. 4].
Tarasenko, V.F., Rybka, D.V., Baksht, E.Kh., et al., Prib. Tekh. Eksp., 2008, no. 2, p. 62 [Instr. Exp. Techn. (Engl. Transl.), vol. 51, no. 2, p. 213].
Author information
Authors and Affiliations
Corresponding author
Additional information
Original Russian Text © V.F. Tarasenko, A.G. Burachenko, E.Kh. Baksht, I.D. Kostyrya, M.I. Lomaev, D.V. Rybka, 2009, published in Pribory i Tekhnika Eksperimenta, 2009, No. 3, pp. 59–62.
Rights and permissions
About this article
Cite this article
Tarasenko, V.F., Burachenko, A.G., Baksht, E.K. et al. A coaxial chopping gap filled with air at atmospheric pressure with a pulse decay time ≤100 ps. Instrum Exp Tech 52, 366–369 (2009). https://doi.org/10.1134/S0020441209030117
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1134/S0020441209030117