Characteristics of copper corrosion in simulated uterine fluid in the presence of protein

  • Published:
Advances in Contraception

Abstract

In order to acquire more knowledge of the performance of copper-bearing intrauterine devices (Cu-IUDs), corrosion behavior of copper in a simulated uterine fluid was investigated in the presence of proteins. The proteins studied included serum albumin, γ-globulin and hemoglobin. Electrochemical polarization resistance measurements indicated that, in all cases under study, the corrosion rate of copper declined with time and the proteins always increased the rate. Moreover, different kinds of protein showed different dependence of copper corrosion rate on protein level. Addition of serum albumin initially raised the copper corrosion rate; however, the higher albumin concentration resulted in less promotion of the corrosion. X-ray diffraction (XRD) of the specimen surface showed that, both in the presence and absence of serum albumin, cuprous oxide was the only corrosion product, even though at higher concentrations of albumin less cuprous oxide was formed. This implies that serum albumin does not alter the corrosion mechanism. Electrochemical cathodic reduction of the oxide film and chemical analysis of solution after corrosion testing proved that the proportion of soluble ionic copper in the whole corrosion products varied with the albumin level. The copper corrosion rate in the presence of γ-globulin or hemoglobin increased monotonically with increasing concentration of the protein. These three proteins shifted the corrosion potential of copper towards negative. It could be inferred that the proteins accelerated the anodic dissolution process of copper and hence enhanced its corrosion.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Zhang CD, Xu NX, Yang BY. The corrosion behavior of copper in simulated uterine fluid. Corrosion Sci. 1996;38:635–41.

    Google Scholar 

  2. Xue HS, Xu NX, Zhang CD. Corrosion behavior of copper in a copper bearing uterine device in the presence of indomethacin. Contraception. 1998;57:49–53.

    Google Scholar 

  3. Xue HS, Xu NX, Zhang CD. Effect of stainless steel on corrosion behavior of copper in a copper-bearing intrauterine device. Adv Contracept. 1998;14:153–60.

    Google Scholar 

  4. Zhang CD, Xu NX, Lu JF, Ding CH, Yang BY. Study on corrosion of copper in artificially formulated fluid using electrochemical method. Reprod Contracept. 1995;15:28–32 (in Chinese).

    Google Scholar 

  5. Oster GK. Chemical reactions of the copper intrauterine device. Fertil Steril. 1972;23(1):18–23.

    Google Scholar 

  6. Lewis KM, Archer RD, Ginsberg AP, Rosencwaig A. The corrosion chemistry of copper intrauterine devices. Contraception. 1977;15(1):93–104.

    Google Scholar 

  7. Tsong YY, Nash HA. Effect of tarnish on copper release. Contraception. 1991;44(4):385–92.

    Google Scholar 

  8. Kosonen A. Corrosion of Copper in utero. In: Hafez ESE, Os van Wan, eds. Medicated Intrauterine Devices. Martinus Nijhoff Press, Amsterdam, pp. 22–9.

  9. Kar AB, Engineer AD, Goel R, Kamboj VP, Dasgupta PR, Chowdhury SR. Effect of an intrauterine contraceptive device on biochemical composition of uterine fluid. Am J Obstet Gynecol. 1968;101(7):966–70.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Zhu, J., Xu, N. & Zhang, C. Characteristics of copper corrosion in simulated uterine fluid in the presence of protein. Advances in Contraception 15, 179–190 (1999). https://doi.org/10.1023/A:1006793231274

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1006793231274

Keywords

Navigation