Transradial retrieval of unintentionally extracted stent deployed 8 months prior during percutaneous coronary intervention to the stent-jailed side branch

  • Case Report
  • Published:
Cardiovascular Intervention and Therapeutics Aims and scope Submit manuscript

Abstract

We experienced a case in which a previously deployed stent was extracted during a percutaneous coronary intervention to the stent-jailed side branch by the transradial approach. The stent was dislodged in the radial artery, was fully expanded, and partially deformed, making it difficult to retrieve via the radial sheath. Using a handmade flared guiding catheter, the expanded deformed stent was successfully retrieved via a 6-Fr radial sheath.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

Similar content being viewed by others

References

  1. Brilakis ES, Best PJ, Elesber AA, Barsness GW, Lennon RJ, Holmes DR Jr, et al. Incidence, retrieval methods, and outcomes of stent loss during percutaneous coronary intervention: a large single-center experience. Catheter Cardiovasc Interv. 2005;66:333–40.

    Article  PubMed  Google Scholar 

  2. Alomar ME, Michael TT, Patel VG, Altomare CG, Rangan BV, Cipher D, et al. Stent loss and retrieval during percutaneous coronary intervention: a systematic review and meta-analysis. J Invasive Cardiol. 2013;25:637–41.

    PubMed  Google Scholar 

  3. Harb TS, Ling FS. Inadvertent stent extraction six months after implantation by an entrapped cutting balloon. Catheter Cardiovasc Interv. 2001;53:415–9.

    Article  CAS  PubMed  Google Scholar 

  4. Kawamura A, Asakura Y, Ishikawa S, Asakura K, Okabe T, Yamane A, et al. Extraction of previously deployed stent by an entrapped cutting balloon due to the blade fracture. Catheter Cardiovasc Interv. 2002;57:239–43.

    Article  PubMed  Google Scholar 

  5. Reffelmann T, Hummel A, Felix SB. Unintentional extraction of a coronary stent deployed 4 months earlier during cutting-balloon angioplasty for in-stent restenosis. J Invasive Cardiol. 2008;20:E208–9.

    PubMed  Google Scholar 

  6. Kirchhof P, Reinecke H. Endovascular extraction of a coronary stent: resolution of a cathlab nightmare. EuroIntervention. 2011;7:1008.

    Article  PubMed  Google Scholar 

  7. Iyisoy A, Celik M, Celik T, Yuksel UC. Inadvertent removal of fully deployed stent during retrieval of another dislodged stent. Int J Cardiol. 2012;156:217–8.

    Article  PubMed  Google Scholar 

  8. Cheema JK, Shroff AR, Vidovich MI. Unintentional extraction of an endothelialized bare metal stent. Cardiovasc Revasc Med. 2013;14:187–90.

    Article  PubMed  Google Scholar 

  9. Baz JA, Jiménez VA, Sepúlveda J, Chantada D, Díaz CM, Juan-Salvadores P, et al. Unintentional extraction of an endothelized coronary stent with an aspiration catheter during primary percutaneous coronary intervention. Circ Cardiovasc Interv. 2015;8:e002114.

    Article  PubMed  Google Scholar 

  10. Hsu PC, Lin TH, Lee WH, Sheu SH. Inadvertent extraction of a deployed stent after using twisted wire technique. Koahsiung J Med Sci. 2014;30:55–6.

    Google Scholar 

  11. Paulus BM, Fischell TA. Retrieval devices and techniques for the extraction of intravascular foreign bodies in the coronary arteries. J Interv Cardiol. 2010;23:271–6.

    Article  PubMed  Google Scholar 

  12. Kwan TW, Chaudhry M, Huang Y, Liou M, Wong S, Zhou X, et al. Approaches for dislodged stent retrieval during transradial percutaneous coronary interventions. Catheter Cardiovasc Interv. 2013;81:E245–9.

    Article  PubMed  Google Scholar 

  13. Porto I, Larosa C, Rosa I, Burzotta F, Trani C. Successful transradial removal of an inflated coronary stent dislodged from the right coronary ostium. Cardiovasc Revasc Med. 2014;15:432–5.

    Article  PubMed  Google Scholar 

  14. Ahmar W, Malaiapan Y, Meredith IT. Transradial retrieval of a dislodged stent from the left main coronary artery. J Invasive Cardiol. 2008;20:545–7.

    PubMed  Google Scholar 

  15. Baszko A, Telec W, Naumowicz E, Siminiak T, Kałmucki P. Stent loss in the radial artery—surgical vs. interventional approach—report of two cases. Postepy Kardiol Interwencyjnej. 2015;11:50–4.

    PubMed  PubMed Central  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Takahiro Sato.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest.

Ethical approval

This article does not contain any studies with human participants or animals performed by any of the authors.

Electronic supplementary material

Below is the link to the electronic supplementary material.

Supplementary material 1 (WMV 4747 kb)

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Sato, T., Irie, T. & Yamane, M. Transradial retrieval of unintentionally extracted stent deployed 8 months prior during percutaneous coronary intervention to the stent-jailed side branch. Cardiovasc Interv and Ther 32, 181–185 (2017). https://doi.org/10.1007/s12928-016-0389-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12928-016-0389-x

Keywords

Navigation