Abstract
The thickness of the dura mater in the human cervical spine can vary between individuals and by vertebral level; these differences can result in various clinical outcomes. The purpose was to measure and analyze cervical dura mater thickness. Microscopic measurements were made of tissue from human cadavers. The subjects were nine human cadavers with no previous history of spinal deformity or surgery. Fourteen segments of both anterior and posterior dura mater from the C1 to C7 cervical vertebrae were obtained. Dura mater thickness was measured using an infrared laser-based confocal microscope. Statistical analyses were performed to examine the relationships of cervical dura mater thickness with vertebral level, age, and sex. The overall average cervical dura mater thickness was 379.3 × 10−3 mm. Statistically significant differences in thickness were found between the anterior and posterior segments (P < 0.0001). Moreover, the thickness at each vertebral level was significantly different from the thicknesses at the other levels (P < 0.05). The posterior dura mater thickness was highest at C1 and lowest at C5/6. Posterior dura mater thickness was significantly different at the axial, sub-axial, and lower cervical levels, whereas anterior dura mater thickness was relatively constant among levels. A significant correlation was found between thickness and age (P < 0.05); however, the average dura mater thickness was not significantly different between males and females. This study shows anatomical differences in cervical dura mater thickness with respect to vertebral level and age. These results provide anatomical information that will inform basic research and clinical approaches.
Similar content being viewed by others
References
Bosacco SJ, Gardner MJ, Guille JT (2001) Evaluation and treatment of dural tears in lumbar spine surgery: a review. Clin Orthop Relat Res 389:238–247
Cain JE, Lauerman WC, Rosenthal HG, Broom MJ, Jacobs RR (1991) The histomorphologic sequence of dural repair. Observations in the canine model. Spine 16(8 Suppl):S319–S323
Celleno D, Capogna G, Costantino P, Catalano P (1993) An anatomic study of the effects of dural puncture with different spinal needles. Reg Anesth 18(4):218–221
Dittmann M, Reina MA, Lopez Garcia A (1998) New results in the visualization of the spinal dura mater with scanning electron microscopy. Der Anaesthesist 47(5):409–413
Eismont FJ, Wiesel SW, Rothman RH (1981) Treatment of dural tears associated with spinal surgery. J Bone Surg Am 63(7):1132–1136
Fink BR, Walker S (1989) Orientation of fibers in human dorsal lumbar dura mater in relation to lumbar puncture. Anesth Analg 69:768–772
Goodkin R, Laska LL (1995) Unintended “incidental” durotomy during surgery of the lumbar spine: medicolegal implications. Surg Neurol 43(1):4–12
Holt SJ, Hicks RM (1961) Studies on formalin fixation for electron microscopy and cytochemical staining purposes. J Biophys Biochem Cytol 11:31–45
Hong JY, Suh SW, Park SY, Modi HN, Rhyu IJ, Kwon S, Yu H, Byun J (2011) Analysis of dural sac thickness in human spine-cadaver study with confocal infrared laser microscope. Spine J 11(12):1121–1127
Jiang DF (1990) Study of some morphologic aspects of the human dura mater. Zhonghua wai ke za zhi 28(2):108-9, 28
Johnston M, Armstrong D, Koh L (2007) Possible role of the cavernous sinus veins in cerebrospinal fluid absorption. Cerebrospinal fluid res 16(4):3
Kitchel SH, Eismont FJ, Green BA (1989) Closed subarachnoid drainage for management of cerebrospinal fluid leakage after an operation on the spine. J Bone Joint Surg Am 71(7):984–987
Koo J, Adamson R, Wagner FC Jr, Hrdy DB (1989) A new cause of chronic meningitis: infected lumbar pseudomeningocele. Am J Med 86(1):103–104
Kwon S, Choi SB, Park MG, Yu H, Suh SW, Rhyu IJ (2013) Extraction of three-dimensional information of biological membranous tissue with scanning confocal infrared laser microscope tomography. Microsc Microanal 19(Suppl 5):194–197
Mack J, Squier W, Eastman JT (2009) Anatomy and development of the meninges: implications for subdural collections and CSF circulation. Pediatr Radiol 39(3):200–210
Moore RA, Bullingham RE, McQuay HJ (1982) Dural permeability to narcotics: in vitro determination and application to extradural administration. Br J Anaesth 54(10):1117–1128
Nakagawa H, Mikawa Y, Watanabe R (1994) Elastin in the human posterior longitudinal ligament and spinal dura. A histologic and biochemical study. Spine 19(19):2164–2169
Nicholas DS, Weller RO (1988) The fine anatomy of the human spinal meninges. A light and scanning electron microscopy study. J Neurosurg 69(2):276–282
Papageorgiou I, Marsh R, Tipper JL, Hall RM, Fisher J, Ingham E (2014) Interaction of micron and nano-sized particles with cells of the dura mater. J Biomed Mater Res B Appl Biomater 102(7):1496–1505
Patin DJ, Eckstein EC, Harum K (1993) Anatomic and biomechanical properties of human lumbar dura mater. Anesth Analg 76:535–540
Reina MA, Lopez-Garcia A, Dittman M (1996) Structural analysis of the thickness of human dura mater with scanning electron microscopy. Rev Esp Anestesiol Reanim 43:135–137
Reina MA, Dittmann M, Lopez Garcia A, van Zundert A (1997) New perspectives in the microscopic structure of human dura mater in the dorsolumbar region. Reg Anesth 22(2):161–166
Reina MA, Lopez Garcia A, de Andres JA, Sellers F, Arrizabalaga M, Mora MJ (1999) Thickness variation of the dural sac. Rev Esp Anestesiol Reanim 46(8):344–349
Reina MA, Villanueva MC, Maches F, Carrera A, Lopez A, De Andres JA (2008) The ultrastructure of the human spinal nerve root cuff in the lumbar spine. Anesth Analg 106(1):339–344
Squier W, Lindberg E, Mack J, Darby S (2009) Demonstration of fluid channels in human dura and their relationship to age and intradural bleeding. Childs Nerv Syst 25(8):925–931
Vandenabeele F, Creemers J, Lambrichts I (1996) Ultrastructure of the human spinal arachnoid mater and dura mater. J Anat 189:417–430
Waisman M, Schweppe Y (1991) Postoperative cerebrospinal fluid leakage after lumbar spine operations. Conservative treatment. Spine 16(1):52–53
Wheeler AH, Murrey DB (2002) Chronic lumbar spine and radicular pain: pathophysiology and treatment. Curr Pain Headache Rep 6(2):97–105
Willatt DJ, Yung MW, Helliwell TR (1987) A correlation of the surgical anatomy of the dura to head and neck surgery. Arch Otorhinolaryngol 243(6):403–406
Yaksh TL, Provencher JC, Rathbun ML, Myers RR, Powell H, Richter P, Kohn FR (2000) Safety assessment of encapsulated morphine delivered epidurally in a sustained-release multivesicular liposome preparation in dogs. Drug Deliv 7(1):7–36
Young IA, Hyman GS, Packia-Raj LN, Cole AJ (2007) The use of lumbar epidural/transforaminal steroids for managing spinal disease. J Am Acad Orthop Surg 15(4):228–238
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
All authors have no conflicts of interest.
Ethical review committee statement
Since this was a cadaver study, an ethical review committee statement was not required.
Rights and permissions
About this article
Cite this article
Kwon, S., Suh, SW., Kim, D. et al. Analysis of dural sac thickness in the human cervical spine. Anat Sci Int 93, 284–290 (2018). https://doi.org/10.1007/s12565-017-0412-z
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12565-017-0412-z