Skip to main content
Log in

Development of an On-line Preconcentration System for Determination of Mercury in Environmental Samples

  • Published:
Water, Air, & Soil Pollution Aims and scope Submit manuscript

Abstract

An on-line preconcentration system using solid-phase extraction with polytetrafluoroethylene was used for the determination of mercury by cold vapor atomic absorption spectrometry. The system uses electronically controlled valves and operates in two simple steps using sorption and elution. The Hg(II) ammonium pyrrolidinedithiocarbamate complexes are retained in a minicolumn packed with the sorbent. The elution, transportation, and reduction of the analyte ions are promoted by a solution of sodium tetrahydroborate(III). After optimization, the developed method showed the following analytical characteristics: a limit of detection of 0.02 μg L−1, linearity of 0.07 to 2.00 μg L−1, enrichment factor of 35, and sampling frequency of 27 h−1. The accuracy of the method was tested by analyzing the certified reference material BCR-060 Lagarosiphon major (aquatic plant). The proposed method was applied to the determination of mercury in water samples.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

Abbreviations

CV-AAS:

Cold vapor atomic absorption spectrometry

CV-AFS:

Cold vapor atomic fluorescence spectrometry

ICP-OES:

Inductively coupled plasma optical emission spectrometry

ICP-MS:

Inductively coupled plasma mass spectrometry

APDC:

Ammonium pyrrolidinedithiocarbamate

PTFE:

Polytetrafluoroethylene

GLS:

Gas-liquid separator

References

  • Acar, D. K., & Kara, D. (2014). A new dispersive liquid–liquid microextraction method for the preconcentration of copper using 4-phenyl-3-thiosemicarbazide and FAAS detection. Water, Air, & Soil Pollution, 225(2), 1864.

    Article  Google Scholar 

  • Adlnasab, L., Ebrahimzadeh, H., Asgharinezhad, A. A., Aghdam, M. N., Dehghani, A., & Esmaeilpour, S. (2014). A preconcentration procedure for determination of ultra-trace mercury (ii) in environmental samples employing continuous-flow cold vapor atomic absorption spectrometry. Food Analytical Methods, 7(3), 616–628.

    Article  Google Scholar 

  • Chandio, Z. A., Talpur, F. N., Khan, H., Afridi, H. I., Khaskheli, G. Q., & Mughal, M. A. (2014). On-line preconcentration and determination of ultra trace amounts of mercury using surfactant coated alumina modified by dithizone with cold vapor atomic absorption spectrometry. RSC Advances, 4(7), 3326–3331.

    Article  CAS  Google Scholar 

  • da Silva, D. G., Portugal, L. A., Serra, A. M., Ferreira, S. L. C., & Cerda, V. (2013). Determination of mercury in rice by MSFIA and cold vapour atomic fluorescence spectrometry. Food Chemistry, 137(1–4), 159–163.

    Article  Google Scholar 

  • de Wuilloud, J. C. A., Wuilloud, R. G., Silva, M. F., Olsina, R. A., & Martinez, L. D. (2002). Sensitive determination of mercury in tap water by cloud point extraction pre-concentration and flow injection-cold vapor-inductively coupled plasma optical emission spectrometry. Spectrochimica Acta Part B-Atomic Spectroscopy, 57(2), 365–374.

    Article  Google Scholar 

  • Escudero, L. B., Olsina, R. A., & Wuilloud, R. G. (2013). Polymer-supported ionic liquid solid phase extraction for trace inorganic and organic mercury determination in water samples by flow injection-cold vapor atomic absorption spectrometry. Talanta, 116, 133–140.

    Article  CAS  Google Scholar 

  • Fang, Z. L., Dong, L. P., & Xu, S. K. (1992). Critical-evaluation of the efficiency and synergistic effects of flow-injection techniques for sensitivity enhancement in flame atomic-absorption spectrometry. Journal of Analytical Atomic Spectrometry, 7(2), 293–299.

    Article  CAS  Google Scholar 

  • Fernandez-Martinez, R., & Rucandio, I. (2013). A simplified method for determination of organic mercury in soils. Analytical Methods, 5(16), 4131–4137.

    Article  CAS  Google Scholar 

  • Geng, W., Nakajima, T., Takanashi, H., & Ohki, A. (2008). Determination of mercury in ash and soil samples by oxygen flask combustion method-cold vapor atomic fluorescence spectrometry (CVAFS). Journal of Hazardous Materials, 154(1–3), 325–330.

    Article  CAS  Google Scholar 

  • Karadaş, C., & Kara, D. (2014). Preconcentration of rare earth elements using amberlite XAD-4 modified with 2,6-pyridinedicarboxaldehyde and their determination by inductively coupled plasma optical emission spectrometry. Water, Air, & Soil Pollution, 225(5), 1972.

    Article  Google Scholar 

  • Lemos, V. A., & Baliza, P. X. (2005). Amberlite XAD-2 functionalized with 2-aminothiophenol as a new sorbent for on-line preconcentration of cadmium and copper. Talanta, 67(3), 564–570.

    Article  CAS  Google Scholar 

  • Lemos, V. A., Novaes, C. G., Lima, A. D., & Vieira, D. R. (2008). Flow injection preconcentration system using a new functionalized resin for determination of cadmium and nickel in tobacco samples. Journal of Hazardous Materials, 155(1–2), 128–134.

    Article  CAS  Google Scholar 

  • Mercader-Trejo, F., Herrera-Basurto, R., de San Miguel, E. R., & de Gyves, J. (2011). Mercury determination in sediments by CVAAS after on line preconcentration by solid phase extraction with a sol–gel sorbent containing CYANEX 471X (R). International Journal of Environmental Analytical Chemistry, 91(11), 1062–1076.

    Article  CAS  Google Scholar 

  • Miller, J. N., & Miller, J. C. (2001). Statistics and chemometrics for analytical chemistry. New York: Prentice Hall.

    Google Scholar 

  • Minnich, M. G., Miller, D. C., & Parsons, P. J. (2008). Determination of As, Cd, Pb, and Hg in urine using inductively coupled plasma mass spectrometry with the direct injection high efficiency nebulizer. Spectrochimica Acta Part B-Atomic Spectroscopy, 63(3), 389–395.

    Article  Google Scholar 

  • Moreno, F., Garcia-Barrera, T., & Gomez-Ariza, J. L. (2013). Simultaneous speciation and preconcentration of ultra trace concentrations of mercury and selenium species in environmental and biological samples by hollow fiber liquid phase microextraction prior to high performance liquid chromatography coupled to inductively coupled plasma mass spectrometry. Journal of Chromatography A, 1300, 43–50.

    Article  CAS  Google Scholar 

  • Puanngam, M., Dasgupta, P. K., & Unob, F. (2012). Automated on-line preconcentration of trace aqueous mercury with gold trap focusing for cold vapor atomic absorption spectrometry. Talanta, 99, 1040–1045.

    Article  CAS  Google Scholar 

  • Qureshi, I., Memon, S., & Yilmaz, M. (2013). Novel calix[4]arene-based amberlite XAD-4 modified resin for As(III) removal from water. Clean: Soil, Air, Water, 41(3), 258–266.

    CAS  Google Scholar 

  • Rivaro, P., Ianni, C., Soggia, F., & Frache, R. (2007). Mercury speciation in environmental samples by cold vapour atomic absorption spectrometry with in situ preconcentration on a gold trap. Microchimica Acta, 158(3–4), 345–352.

    Article  CAS  Google Scholar 

  • Sarıca, D. Y., & Türker, A. R. (2012). Speciation and determination of inorganic mercury and methylmercury by headspace single drop microextraction and electrothermal atomic absorption spectrometry in water and fish. Clean: Soil, Air, Water, 40(5), 523–530.

    Google Scholar 

  • Shah, A. Q., Kazi, T. G., Baig, J. A., Afridi, H. I., & Arain, M. B. (2012). Simultaneously determination of methyl and inorganic mercury in fish species by cold vapour generation atomic absorption spectrometry. Food Chemistry, 134(4), 2345–2349.

    Article  CAS  Google Scholar 

  • Shah, F., Soylak, M., Kazi, T. G., & Afridi, H. I. (2013). Preconcentration of lead from aqueous solution with activated carbon cloth prior to analysis by flame atomic absorption spectrometry: a multivariate study. Journal of Analytical Atomic Spectrometry, 28(4), 601–605.

    Article  CAS  Google Scholar 

  • Stanisz, E., Werner, J., & Matusiewicz, H. (2014). Task specific ionic liquid-coated PTFE tube for solid-phase microextraction prior to chemical and photo-induced mercury cold vapour generation. Microchemical Journal, 114, 229–237.

    Article  CAS  Google Scholar 

  • Trujillo, I. S., Castillo, M. L. A., Pavon, J. M. C., Alonso, E. I. V., & de Torres, A. G. (2013). Flow injection on-line solid phase extraction for ultra-trace lead determination with hydride generation electrothermal atomic absorption spectrometry. Analytical Methods, 5(10), 2551–2557.

    Article  CAS  Google Scholar 

  • Turker, A. R., Cabuk, D., & Yalcinkaya, O. (2013). Preconcentration, speciation, and determination of mercury by solid phase extraction with cold vapor atomic absorption spectrometry. Analytical Letters, 46(7), 1155–1170.

    Article  CAS  Google Scholar 

  • Tuzen, M., & Soylak, M. (2005). Mercury contamination in mushroom samples from Tokat, Turkey. Bulletin of Environmental Contamination and Toxicology, 74(5), 968–972.

    Article  CAS  Google Scholar 

  • Tuzen, M., Karaman, I., Citak, D., & Soylak, M. (2009a). Mercury(II) and methyl mercury determinations in water and fish samples by using solid phase extraction and cold vapour atomic absorption spectrometry combination. Food and Chemical Toxicology, 47(7), 1648–1652.

    Article  CAS  Google Scholar 

  • Tuzen, M., Uluozlu, O. D., Karaman, I., & Soylak, M. (2009b). Mercury(II) and methyl mercury speciation on Streptococcus pyogenes loaded Dowex Optipore SD-2. Journal of Hazardous Materials, 169(1–3), 345–350.

    Article  CAS  Google Scholar 

  • Yuan, C. G., Wang, J. C., Zhai, W. H., Zhang, Y., Zhang, Y. Y., Li, J., et al. (2013). Silver modified magnetic carbon nanotubes composite as a selective solid phase extractor for preconcentration and determination of trace mercury ions in water solution. International Journal of Environmental Analytical Chemistry, 93(14), 1513–1524.

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Valfredo Azevedo Lemos.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

dos Santos, L.O., Lemos, V.A. Development of an On-line Preconcentration System for Determination of Mercury in Environmental Samples. Water Air Soil Pollut 225, 2086 (2014). https://doi.org/10.1007/s11270-014-2086-7

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1007/s11270-014-2086-7

Keywords

Navigation