Abstract

Background

The objectives of this study were to assess the procedural outcomes of persistent and long-standing persistent atrial fibrillation (PsAF and L-PsAF) ablation guided by remote magnetic navigation (RMN), and to detect factors predicting acute restoration of sinus rhythm (SR) by ablation with RMN.

Methods

A total of 313 patients (275 male, age 59 ± 9.5 years) with PsAF (187/313) or L-PsAF (126/313) undergoing ablation using RMN were included. Patients’ disease history, pulmonary venous anatomy, left atrial (LA) volume, procedure time, mapping plus ablation time, radiofrequency (RF) ablation time, fluoroscopy time, radiation dose, and complications were assessed. Stepwise regression was used to predict which variable could best predict acute restoration from AF to SR by ablation.

Results

Compared to PsAF, procedure time and RF ablation time were significantly increased in patients with L-PsAF (P = 0.01 and P < 0.001, respectively). No major complications occurred during the procedures in either PsAF or L-PsAF patients. Fifty five of 313 patients converted directly to SR by ablation. Compared to L-PsAF, the rate of SR restoration was significantly higher in PsAF (21 vs 12 %, P = 0.03). Stepwise regression analysis showed LA volume was the primary parameter affecting SR restoration (P = 0.01). The LA volume of patients without direct SR restoration by ablation was 24 % greater than that of patients with SR restoration (P < 0.001).

Conclusions

Catheter ablation using RMN is a safe and effective method for PsAF and L-PsAF. LA volume could be a predictor of direct restoration of SR from sustaining AF by ablation using RMN.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Mont, L., Bisbal, F., Hernandez-Madrid, A., Perez-Castellano, N., Vinolas, X., Arenal, A., Arribas, F., Fernandez-Lozano, I., Bodegas, A., Cobos, A., Matia, R., Perez-Villacastin, J., Guerra, J. M., Avila, P., Lopez-Gil, M., Castro, V., Arana, J. I., Brugada, J., & SARA Investigators. (2014). Catheter ablation vs. antiarrhythmic drug treatment of persistent atrial fibrillation: a multicentre, randomized, controlled trial (SARA study). European Heart Journal, 35, 501–507.

    Article  PubMed  PubMed Central  Google Scholar 

  2. Faddis, M. N., Chen, J., Osborn, J., Talcott, M., Cain, M. E., & Lindsay, B. D. (2003). Magnetic guidance system for cardiac electrophysiology: a prospective trial of safety and efficacy in humans. Journal of the American College of Cardiology, 42, 1952–1958.

    Article  PubMed  Google Scholar 

  3. Bradfield, J., Tung, R., Mandapati, R., Boyle, N. G., & Shivkumar, K. (2012). Catheter ablation utilizing remote magnetic navigation: a review of applications and outcomes. Pacing and Clinical Electrophysiology, 35, 1021–1034.

    Article  PubMed  Google Scholar 

  4. Proietti, R., Pecoraro, V., Di Biase, L., Natale, A., Santangeli, P., Viecca, M., Sagone, A., Galli, A., Moja, L., & Tagliabue, L. (2013). Remote magnetic with open-irrigated catheter vs. manual navigation for ablation of atrial fibrillation: a systematic review and meta-analysis. Europace, 15, 1241–1248.

    Article  PubMed  Google Scholar 

  5. De Vries, L. J., Akca, F., Khan, M., Dabiri-Abkenari, L., Janse, P., Theuns, D. A., Peters, E., De Ruiter, G., & Szili-Torok, T. (2014). Clinical outcome of ablation for long-standing persistent atrial fibrillation with or without defragmentation. Netherlands Heart Journal, 22, 30–36.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  6. Forclaz, A., Narayan, S. M., Scherr, D., Linton, N., Jadidi, A. S., Nault, I., Rivard, L., Miyazaki, S., Uldry, L., Wright, M., Shah, A. J., Liu, X., Xhaet, O., Derval, N., Knecht, S., Sacher, F., Jais, P., Hocini, M., & Haissaguerre, M. (2011). Early temporal and spatial regularization of persistent atrial fibrillation predicts termination and arrhythmia-free outcome. Heart Rhythm, 8, 1374–1382.

    Article  PubMed  PubMed Central  Google Scholar 

  7. Heist, E. K., Chalhoub, F., Barrett, C., Danik, S., Ruskin, J. N., & Mansour, M. (2012). Predictors of atrial fibrillation termination and clinical success of catheter ablation of persistent atrial fibrillation. The American Journal of Cardiology, 110, 545–551.

    Article  PubMed  Google Scholar 

  8. Drewitz, I., Willems, S., Salukhe, T. V., Steven, D., Hoffmann, B. A., Servatius, H., Bock, K., Aydin, M. A., Wegscheider, K., Meinertz, T., & Rostock, T. (2010). Atrial fibrillation cycle length is a sole independent predictor of a substrate for consecutive arrhythmias in patients with persistent atrial fibrillation. Circulation. Arrhythmia and Electrophysiology, 3, 351–360.

    Article  PubMed  Google Scholar 

  9. Nault, I., Lellouche, N., Matsuo, S., Knecht, S., Wright, M., Lim, K. T., Sacher, F., Platonov, P., Deplagne, A., Bordachar, P., Derval, N., O’Neill, M. D., Klein, G. J., Hocini, M., Jais, P., Clementy, J., & Haissaguerre, M. (2009). Clinical value of fibrillatory wave amplitude on surface ECG in patients with persistent atrial fibrillation. Journal of Interventional Cardiac Electrophysiology, 26, 11–19.

    Article  PubMed  Google Scholar 

  10. Pappone, C., Vicedomini, G., Manguso, F., Gugliotta, F., Mazzone, P., Gulletta, S., Sora, N., Sala, S., Marzi, A., Augello, G., Livolsi, L., Santagostino, A., & Santinelli, V. (2006). Robotic magnetic navigation for atrial fibrillation ablation. Journal of the American College of Cardiology, 47, 1390–1400.

    Article  PubMed  Google Scholar 

  11. Pezawas, T., Ristl, R., Bilinski, M., Schukro, C., & Schmidinger, H. (2014). Single, remote-magnetic catheter approach for pulmonary vein isolation in patients with paroxysmal and non-paroxysmal atrial fibrillation. International Journal of Cardiology, 174, 18–24.

    Article  PubMed  Google Scholar 

  12. Luthje, L., Vollmann, D., Seegers, J., Dorenkamp, M., Sohns, C., Hasenfuss, G., & Zabel, M. (2011). Remote magnetic versus manual catheter navigation for circumferential pulmonary vein ablation in patients with atrial fibrillation. Clinical Research in Cardiology, 100, 1003–1011.

    Article  PubMed  PubMed Central  Google Scholar 

  13. Nademanee, K., McKenzie, J., Kosar, E., Schwab, M., Sunsaneewitayakul, B., Vasavakul, T., Khunnawat, C., & Ngarmukos, T. (2004). A new approach for catheter ablation of atrial fibrillation: mapping of the electrophysiologic substrate. Journal of the American College of Cardiology, 43, 2044–2053.

    Article  PubMed  Google Scholar 

  14. Estner, H. L., Hessling, G., Ndrepepa, G., Luik, A., Schmitt, C., Konietzko, A., Ucer, E., Wu, J., Kolb, C., Pflaumer, A., Zrenner, B., & Deisenhofer, I. (2008). Acute effects and long-term outcome of pulmonary vein isolation in combination with electrogram-guided substrate ablation for persistent atrial fibrillation. The American Journal of Cardiology, 101, 332–337.

    Article  PubMed  Google Scholar 

  15. Cappato, R., Calkins, H., Chen, S. A., Davies, W., Iesaka, Y., Kalman, J., Kim, Y. H., Klein, G., Natale, A., Packer, D., Skanes, A., Ambrogi, F., & Biganzoli, E. (2010). Updated worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation. Circulation. Arrhythmia and Electrophysiology, 3, 32–38.

    Article  PubMed  Google Scholar 

  16. Choi, M. S., Oh, Y. S., Jang, S. W., Kim, J. H., Shin, W. S., Youn, H. J., Jung, W. S., Lee, M. Y., & Seong, K. B. (2011). Comparison of magnetic navigation system and conventional method in catheter ablation of atrial fibrillation: is magnetic navigation system is more effective and safer than conventional method? Korean Circulation Journal, 41, 248–252.

    Article  PubMed  PubMed Central  Google Scholar 

  17. Miyazaki, S., Shah, A. J., Xhaet, O., Derval, N., Matsuo, S., Wright, M., Nault, I., Forclaz, A., Jadidi, A. S., Knecht, S., Rivard, L., Liu, X., Linton, N., Sacher, F., Hocini, M., Jais, P., & Haissaguerre, M. (2010). Remote magnetic navigation with irrigated tip catheter for ablation of paroxysmal atrial fibrillation. Circulation. Arrhythmia and Electrophysiology, 3, 585–589.

    Article  PubMed  Google Scholar 

  18. Solheim, E., Off, M. K., Hoff, P. I., De Bortoli, A., Schuster, P., Ohm, O. J., & Chen, J. (2011). Remote magnetic versus manual catheters: evaluation of ablation effect in atrial fibrillation by myocardial marker levels. Journal of Interventional Cardiac Electrophysiology, 32, 37–43.

    Article  PubMed  PubMed Central  Google Scholar 

  19. Calkins, H., Kuck, K. H., Cappato, R., et al. (2012). 2012 HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation. Heart Rhythm, 9, 632–696. e621.

    Article  PubMed  Google Scholar 

  20. Elayi, C. S., Di Biase, L., Barrett, C., Ching, C. K., Al Aly, M., Lucciola, M., Bai, R., Horton, R., Fahmy, T. S., Verma, A., Khaykin, Y., Shah, J., Morales, G., Hongo, R., Hao, S., Beheiry, S., Arruda, M., Schweikert, R. A., Cummings, J., Burkhardt, J. D., Wang, P., Al-Ahmad, A., Cauchemez, B., Gaita, F., & Natale, A. (2010). Atrial fibrillation termination as a procedural endpoint during ablation in long-standing persistent atrial fibrillation. Heart Rhythm, 7, 1216–1223.

    Article  PubMed  Google Scholar 

  21. Park, Y. M., Choi, J. I., Lim, H. E., Park, S. W., & Kim, Y. H. (2012). Is pursuit of termination of atrial fibrillation during catheter ablation of great value in patients with longstanding persistent atrial fibrillation? Journal of Cardiovascular Electrophysiology, 23, 1051–1058.

    Article  PubMed  Google Scholar 

  22. Lo, L. W., Tai, C. T., Lin, Y. J., Chang, S. L., Udyavar, A. R., Hu, Y. F., Ueng, K. C., Tsai, W. C., Tuan, T. C., Chang, C. J., Kao, T., Tsao, H. M., Wongcharoen, W., Higa, S., & Chen, S. A. (2009). Predicting factors for atrial fibrillation acute termination during catheter ablation procedures: implications for catheter ablation strategy and long-term outcome. Heart Rhythm, 6, 311–318.

    Article  PubMed  Google Scholar 

  23. Hof, I., Arbab-Zadeh, A., Scherr, D., Chilukuri, K., Dalal, D., Abraham, T., Lima, J., & Calkins, H. (2009). Correlation of left atrial diameter by echocardiography and left atrial volume by computed tomography. Journal of Cardiovascular Electrophysiology, 20, 159–163.

    Article  PubMed  Google Scholar 

Download references

Acknowledgments

The authors wish to thank the technical staff of the Cardiac Catheterization Laboratory for their help.

Conflict of interest

The authors declare that they have no competing interests.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Xu Chen.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Jin, Q., Pehrson, S., Jacobsen, P.K. et al. Impact of catheter ablation with remote magnetic navigation on procedural outcomes in patients with persistent and long-standing persistent atrial fibrillation. J Interv Card Electrophysiol 44, 197–204 (2015). https://doi.org/10.1007/s10840-015-0037-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10840-015-0037-x

Keywords

Navigation